Tissue Stability of Implants Placed in Fresh Extraction Sockets: A 5-Year Prospective Single-Cohort Study

被引:31
|
作者
Covani, Ugo [1 ,2 ]
Canullo, Luigi [2 ]
Toti, Paolo [1 ,2 ]
Alfonsi, Fortunato [2 ]
Barone, Antonio [1 ,2 ]
机构
[1] Univ Pisa, Dept Surg Med Mol & Crit Area Pathol, I-55041 Camaiore, Italy
[2] Versilia Gen Hosp, Tuscan Stomatol Inst, Lido Di Camaiore, Italy
关键词
Alveolar bone grafting; alveolar bone loss; dental implants; single-tooth; gingival recession; materials; biocompatible; tooth extraction; RIDGE PRESERVATION TECHNIQUES; TOOTH IMPLANTS; CASE-SERIES; ANTERIOR MAXILLA; FOLLOW-UP; IMMEDIATE PLACEMENT; CLINICAL-TRIAL; AESTHETIC ZONE; HARD; SOFT;
D O I
10.1902/jop.2014.140175
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Several materials have been used for ridge preservation after tooth extraction. This 5-year prospective single-cohort study is aimed at evaluating the success rate, marginal bone level (MBL), soft tissue stability, and subjective patient evaluation of implants placed in fresh extraction sockets with the use of a flapless technique and a xenograft to treat the peri-implant bone defect. Methods: Patients requiring a single implant in fresh extraction sockets were selected. After flapless extraction and implant insertion, the peri-implant bone defect was grafted with porcine bone. Collagen membrane was used to stabilize the graft. Four months later, a second surgery and prosthetic procedures were performed. Clinical parameters (width of keratinized gingiva [WKG], facial soft tissue level [FST], papilla index, plaque index, and bleeding on probing) were measured, and periapical radiographs were taken at the time of implant placement (baseline) and then at 1, 3, and 5 years thereafter. Image analysis software was applied to measure changes in the marginal bone level (Delta MBL). Additionally, patient satisfaction regarding the implant treatment was evaluated. All analyses were collected and measured by an independent, trained observer. Together with descriptive statistics, for each of the outcome variables, pairwise comparisons were performed using the Wilcoxon signed-rank test for matched samples. The level of statistical significance was set at 0.01 for all analyses. Results: Forty-seven consecutive patients were treated, with an implant survival rate at 5 years of 95.7%. Delta MBL showed statistically significant differences: mean values were -0.68 +/- 0.39, -0.94 +/- 0.44, and -1.08 +/- 0.43 mm at the 1, 3, and 5-year follow-up, respectively. Changes in WKG (Delta WKG) and FST (Delta FST) decreased from the 1-year point of the survey (0.80 +/- 0.79 and 0.71 +/- 0.73 mm for Delta WKG and Delta FST, respectively) to the last follow-up check at 5 years (0.67 +/- 0.74 and 0.56 +/- 0.69 mm for Delta WKG and Delta FST, respectively), with no significant differences. The papilla indexes showed significant differences among the baseline and all the other time points. Concerning patient satisfaction, at the last survey time point, 74% +/- 11.8% of patients were satisfied regarding the overall implant treatment, 73.0% +/- 11.1% gave a favorable opinion regarding the appearance of the peri-implant soft tissues, and 80.5% +/- 11.3% judged positively the finished appearance of the implant crown. No significant differences were obtained among the three follow-up times. Conclusions: The data of the present study suggest that the placement of a dental implant by means of a flapless technique in a fresh extraction socket filled with slowly resorbable graft biomaterial and with a delayed prosthetic restoration shows positive final esthetic outcomes. At the 5-year point of the survey, the changes in the bone level were minimal. Moreover, both midfacial tissue and the papillae maintained the early increase recorded before the first year of the follow-up.
引用
收藏
页码:E323 / E332
页数:10
相关论文
共 50 条
  • [21] Immediately provisionalized tapered conical connection implants for single-tooth restorations in the maxillary esthetic zone: a 5-year prospective single-cohort multicenter analysis
    Baer, Russell A.
    Noelken, Robert
    Colic, Snjezana
    Heydecke, Guido
    Mirzakhanian, Christine
    Behneke, Alexandra
    Behneke, Nikolaus
    Gottesman, Edward
    Ottria, Liliana
    Pozzi, Alessandro
    Fuegl, Alexander
    Zechner, Werner
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (04) : 3593 - 3604
  • [22] Immediately provisionalized tapered conical connection implants for single-tooth restorations in the maxillary esthetic zone: a 5-year prospective single-cohort multicenter analysis
    Russell A. Baer
    Robert Nölken
    Snjezana Colic
    Guido Heydecke
    Christine Mirzakhanian
    Alexandra Behneke
    Nikolaus Behneke
    Edward Gottesman
    Liliana Ottria
    Alessandro Pozzi
    Alexander Fügl
    Werner Zechner
    Clinical Oral Investigations, 2022, 26 : 3593 - 3604
  • [23] A 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla
    Berberi, Antoine N.
    Sabbagh, Joseph M.
    Aboushelib, Moustafa N.
    Noujeim, Ziad F.
    Salameh, Ziad A.
    FRONTIERS IN PHYSIOLOGY, 2014, 5
  • [25] Esthetic Assessment of Implants Placed into Fresh Extraction Sockets for Single-Tooth Replacements Using a Flapless Approach
    Kolerman, Roni
    Mijiritsky, Eitan
    Barnea, Eitan
    Dabaja, Areeje
    Nissan, Joseph
    Tal, Haim
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (02) : 351 - 364
  • [26] A 1-Year Controlled Clinical Trial of Immediate Implants Placed in Fresh Extraction Sockets: Stability Measurements and Crestal Bone Level Changes
    Huber, Sandra
    Rentsch-Kollar, Andrea
    Grogg, Fabiana
    Katsoulis, Joannis
    Mericske, Regina
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (04) : 491 - 500
  • [27] A systematic review on survival and success rates of implants placed immediately into fresh extraction sockets after at least 1 year
    Lang, Niklaus P.
    Pun, Lui
    Lau, Ka Yee
    Li, Ka Yan
    Wong, May C. M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 : 39 - 66
  • [28] A 4-Year Evaluation of the Peri-Implant Parameters of Immediately Loaded Implants Placed in Fresh Extraction Sockets
    Crespi, Roberto
    Cappare, Paolo
    Gherlone, Enrico
    JOURNAL OF PERIODONTOLOGY, 2010, 81 (11) : 1629 - 1634
  • [29] Implant stability measurements for implants placed at the time of extraction: A cohort, prospective clinical trial
    Becker, W
    Sennerby, L
    Bedrossian, E
    Becker, BE
    Lucchini, JP
    JOURNAL OF PERIODONTOLOGY, 2005, 76 (03) : 391 - 397
  • [30] EVALUATION OF GUIDED BONE GENERATION AROUND IMPLANTS PLACED INTO FRESH EXTRACTION SOCKETS - AN EXPERIMENTAL-STUDY IN DOGS
    GOTFREDSEN, K
    NIMB, L
    BUSER, D
    HJORTINGHANSEN, E
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (08) : 879 - 884