A 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla

被引:20
|
作者
Berberi, Antoine N. [1 ]
Sabbagh, Joseph M.
Aboushelib, Moustafa N. [2 ]
Noujeim, Ziad F. [1 ]
Salameh, Ziad A. [2 ]
机构
[1] Lebanese Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Beirut, Lebanon
[2] Lebanese Univ, Sch Dent, Dept Res, Beirut, Lebanon
关键词
marginal bone level; peri-apical radiographs; dental implant; immediate loading; maxillae; healed sockets; fresh extraction sockets; single-tooth; DENTAL IMPLANTS; ANTERIOR MAXILLA; EDENTULOUS MAXILLA; AESTHETIC ZONE; PROVISIONALIZATION; SOFT; HARD; REPLACEMENTS; RESTORATION; OUTCOMES;
D O I
10.3389/fphys.2014.00029
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: The aim of present investigation was to evaluate marginal bone level after 5-year follow-up of implants placed in healed ridges and fresh extraction sockets in maxilla with immediate loading protocol. Materials and Methods: Thirty-six patients in need of a single-tooth replacement in the anterior maxilla received 42 Astra Tech implants (Astra Tech Implant system (TM), Dentsply Implants, Molndal, Sweden). Implants were placed either in healed ridges (group I) or immediately into fresh extraction sockets (group II). Implants were restored and placed into functional loading immediately by using a prefabricated abutment. Marginal bone level relative to the implant reference point was recorded at implant placement, crown cementation, 12,36, and 60 months following loading using intra-oral radiographs. Measurements were made on the mesial and distal sides of each implant. Results: Overall, two implants were lost from the group II, before final crown cementation: they were excluded from the study. The mean change in marginal bone loss (MBL) after implant placement was 0.26 +/- 0.161 mm for 1 year, and 0.26 +/- 0.171 mm for 3 years, and 0.21 +/- 0.185 mm for 5 years in extraction sockets and was 0.26 +/- 0.176 mm for 1 year and 0.21 +/- 0.175 mm for 3 years, and 0.19 +/- 0.172 mm for 5 years in healed ridges group. Significant reduction of marginal bone was more pronounced in implants inserted in healed ridges (P < 0.041) compared to fresh surgical extraction sockets (P < 0.540). Significant MBL was observed on the mesial side of the implant after cementation of the provisional (P < 0.007) and after 12 months (P < 0.034) compared to the distal side which remained stable for 3 and 5 years observation period. Conclusions: Within the limitations of this study, responses of local bone to immediately loaded implants placed either in extraction sockets or healed ridges were similar. Functional loading technique by using prefabricated abutment placed during the surgery time seems to maintain marginal bone around implant in both healed and fresh extraction sites.
引用
收藏
页数:7
相关论文
共 41 条
  • [1] Comparison of Radiographic and Clinical Outcomes Following Immediate Provisionalization of Single-Tooth Dental Implants Placed in Healed Alveolar Ridges and Extraction Sockets
    Cooper, Lyndon F.
    Raes, Filiep
    Reside, Glenn J.
    Garriga, Joan Soliva
    Tarrida, Luis Giner
    Wiltfang, Jorg
    Kern, Matthias
    De Bruyn, Hugo
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (06) : 1222 - 1232
  • [2] Immediate Provisionalization of Dental Implants Placed in Healed Alveolar Ridges and Extraction Sockets: A 5-year Prospective Evaluation
    Cooper, Lyndon F.
    Reside, Glenn J.
    Raes, Filiep
    Soliva Garriga, Joan
    Giner Tarrida, Luis
    Wiltfang, Joerg
    Kern, Matthias
    De Bruyn, Hugo
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 709 - 717
  • [3] Immediate loading of single-tooth ITI implants in the anterior maxilla:: a prospective 5-year pilot study
    Andersen, E
    Haanæs, HR
    Knutsen, BM
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) : 281 - 287
  • [4] Esthetic Evaluation of Single-Tooth Worse Taper Connection Implants Placed in Fresh Extraction Sockets or Healed Sites
    Mangano, Francesco G.
    Mangano, Carlo
    Ricci, Massimiliano
    Sammons, Rachel L.
    Shibli, Jamil A.
    Piattelli, Adriano
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (02) : 172 - 181
  • [5] Immediate restoration of implants placed into fresh extraction sockets for single-tooth replacement: A prospective clinical study
    Cornelini, R
    Cangini, F
    Covani, U
    Wilson, TG
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2005, 25 (05) : 439 - 447
  • [6] Immediate loading of a fully tapered implant with deep apical threads placed in healed alveolar ridges vs. immediate extraction sockets
    Hadaya, Danny
    Pi-Anfruns, Joan
    Bellon, Benjamin
    Pippenger, Benjamin E.
    Aghaloo, Tara L.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (05) : 501 - 510
  • [7] Single-tooth Morse taper connection implants placed in fresh extraction sockets of the anterior maxilla: an aesthetic evaluation
    Mangano, Francesco
    Mangano, Carlo
    Ricci, Massimiliano
    Sammons, Rachel Lilian
    Shibli, Jamil Awad
    Piattelli, Adriano
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (11) : 1302 - 1307
  • [8] A Randomized Clinical Trial Comparing Immediate Loading and Delayed Loading of Single-Tooth Implants: 5-Year Results
    Gjelvold, Bjorn
    Kisch, Jeno
    Chrcanovic, Bruno R.
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (05) : 1 - 9
  • [9] Immediate loading of single-tooth implants in the anterior maxilla. Preliminary results after one year
    Lorenzoni, M
    Pertl, C
    Zhang, KH
    Wimmer, G
    Wegscheider, WA
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (02) : 180 - 187