The study of the electrochemical behaviour of 316L stainless steel bioimplants in physiological serum

被引:0
|
作者
Tutunaru, B [1 ]
Samide, A [1 ]
Preda, M [1 ]
机构
[1] Univ Din Craiova, Fac Chim, Craiova 200620, Romania
来源
REVISTA DE CHIMIE | 2004年 / 55卷 / 10期
关键词
corrosion; implant; 316L alloys; physiological serum;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The corrosion of metallic biomaterials made from 316L stainless steel in physiological serum has been explained according to electrochemical theory using the potentiostatic, galvanostatic and cyclic voltammetry methods. The corrosion potential was stabilised at -176 m V after 1000 h of immersion. Potentiostatic measurement shows a passivation current of 80 muA/cm(2), cyclic voltammograms reveal a critical pitting potential (E-cp) about 1600 mV and a pit protection potential (E-pp) about 1300 mV.
引用
收藏
页码:757 / 758
页数:2
相关论文
共 50 条
  • [21] Tribological behaviour of AISI 316L stainless steel for biomedical applications
    Fellah, M.
    Labaiz, M.
    Assala, O.
    Iost, A.
    Dekhil, Leila
    TRIBOLOGY-MATERIALS SURFACES & INTERFACES, 2013, 7 (03) : 135 - 149
  • [22] Some studies on the machining behaviour of 316L austenitic stainless steel
    Philip A.M.
    Chakraborty K.
    Materials Today: Proceedings, 2022, 56 : 681 - 685
  • [23] Reveal the Viscoplastic Behaviour and Microstructure Evolution of Stainless Steel 316L
    Lu, Qiong
    Zhang, Chi
    Wang, Wei
    Jiang, Shuai
    Aucott, Lee
    Yasmeen, Tabassam
    Jiang, Jun
    MATERIALS, 2022, 15 (20)
  • [24] FATIGUE BEHAVIOUR OF COPPER-BRAZED 316L STAINLESS STEEL
    Kralj, Jernej
    Hanzelic, Blaz
    Glodez, Sreko
    Kramberger, Janez
    Satosek, Roman
    Necemer, Branko
    MATERIALI IN TEHNOLOGIJE, 2024, 58 (03): : 433 - 440
  • [25] Analysis of texture effects on fatigue behaviour of 316L stainless steel
    Villechaise, P
    Mineur, M
    Mendez, J
    JOURNAL DE PHYSIQUE IV, 2001, 11 (PR4): : 311 - 319
  • [26] Tribocorrosion behaviour of DLC-coated 316L stainless steel
    Azzi, M.
    Paquette, M.
    Szpunar, J. A.
    Klemberg-Sapieha, J. E.
    Martinu, L.
    WEAR, 2009, 267 (5-8) : 860 - 866
  • [27] Polarisation behaviour of 316L stainless steel in cell culture environment
    Hiromoto, Sachiko
    PRICM 6: SIXTH PACIFIC RIM INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND PROCESSING, PTS 1-3, 2007, 561-565 : 1459 - 1462
  • [28] Fatigue behaviour of duplex treated AISI 316L stainless steel
    Celik, A.
    Arslan, Y.
    Yetim, A. F.
    Efeoglu, I.
    KOVOVE MATERIALY-METALLIC MATERIALS, 2007, 45 (01): : 35 - 40
  • [29] The Fracture and Fragmentation Behaviour of Additively Manufactured Stainless Steel 316L
    Amott, R.
    Harris, E. J.
    Winter, R. E.
    Stirk, S. M.
    Chapman, D. J.
    Eakins, D. E.
    SHOCK COMPRESSION OF CONDENSED MATTER - 2015, 2017, 1793
  • [30] Correlation of passivation treatments on 316L stainless steel with electrochemical behavior
    Kanani, Andrea
    Rohly, Kenneth
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247