Incomplete fluid-air exchange technique for idiopathic macular hole surgery

被引:1
|
作者
Hu, Bo Jie [1 ]
Du, Xue-Li [1 ]
Li, Wen-Bo [1 ]
Chang, Yu-Wen [2 ]
Shi, Xing-Dong [3 ]
Ma, Teng [1 ]
Wang, Yong [1 ]
He, Yan-Hua [1 ]
Niu, Rui [1 ]
Cui, Wei-Na [1 ]
机构
[1] Tianjin Med Univ, Dept Retina, Eye Hosp, 251 Fukang Rd, Tianjin 300384, Peoples R China
[2] Peoples Hosp Hetian Dist, Xinjiang 848000, Uygur Autonomou, Peoples R China
[3] Tianjin First Cent Hosp, Dept Ophthalmol, Tianjin 300192, Peoples R China
关键词
best-corrected visual acuity; electroretinography; internal limiting membrane; macular hole; fluid-air exchange; visual field defect; VISUAL-FIELD LOSS; PARS-PLANA VITRECTOMY; VITREOUS SURGERY; OUTCOMES; DEFECTS; INFUSION;
D O I
10.18240/ijo.2019.10.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To explore an improved procedure involving incomplete fluid-air exchange for idiopathic macular hole (IMH), and the closure rate, visual function, and the visual field of macular holes (MHs) were evaluated. METHODS: This prospective randomized controlled study, included 40 eyes of 40 patients with IMH who were treated with pars plana vitrectomy and peeling of the internal limiting membrane. They were grouped by random digital table. Twenty-one eyes underwent incomplete fluidair exchange (IFA) and 19 eyes underwent traditional complete fluid-air exchange (CFA) as the control group. Outcomes included best-corrected visual acuity (BCVA), intraocular pressure, and optical coherence tomography, light adaptive electroretinography, and visual field evaluations. RESULTS: All MHs <400 mu m were successfully closed. BCVAs before and 6mo after surgery were 0.82 +/- 0.41 logMAR and 0.28 +/- 0.17 logMAR in IFA group and 0.86 +/- 0.34 logMAR and 0.34 +/- 0.23 log MAR in CFA group, respectively. The electroretinogram analysis of patients in IFA group revealed increases in b-wave amplitudes at 1, 3, and 6mo after surgery. Additionally, patients in IFA group showed an amplitude increase of 28.6% from baseline at 6mo (P<0.05), while no obvious improvements were noted in CFA group. Although there were no statistically significant improvements in either group, the IFA group showed a slight increase in mean sensitivity (P>0.05). CONCLUSION: IFA is a reliable method that offers comparable closure rate to CFA and facilitates improvements in visual function.
引用
收藏
页码:1582 / 1588
页数:7
相关论文
共 50 条
  • [41] Retinal displacement after surgery for idiopathic macular hole
    Qin, He-Cong
    Li, Fu-Qiang
    Jin, Si-Yan
    Zhao, Jin-Song
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (08) : 1545 - 1556
  • [42] Ethnic variation in primary idiopathic macular hole surgery
    Chandra, A.
    Lai, M.
    Mitry, D.
    Banerjee, P. J.
    Flayeh, H.
    Negretti, G.
    Kumar, N.
    Wickham, L.
    EYE, 2017, 31 (05) : 708 - 712
  • [43] CONDENSATION ON THE POSTERIOR SURFACE OF SILICONE INTRAOCULAR LENSES DURING FLUID-AIR EXCHANGE
    EATON, AM
    JAFFE, GJ
    MCCUEN, BW
    MINCEY, GJ
    OPHTHALMOLOGY, 1995, 102 (05) : 733 - 736
  • [44] Efficacy of autologous plasmin for idiopathic macular hole surgery
    Sakuma, T
    Tanaka, M
    Inoue, J
    Mizota, A
    Souri, M
    Ichinose, A
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (06) : 787 - 794
  • [45] Foveal Detachment after Idiopathic Macular Hole Surgery
    Tadayoni, Ramin
    Boulanger-Scemama, Elise
    Couturier, Aude
    Hage, Rabih
    Massin, Pascale
    Gaudric, Alain
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [46] Response to “Use of air in macular hole surgery”
    Yuhei Hasegawa
    Yasauki Hata
    Yasutaka Mochizuki
    Ryoichi Arita
    Shuhei Kawahara
    Takeshi Kita
    Yoshihiro Noda
    Tatsuro Ishibashi
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 909 - 909
  • [47] Response to "Use of air in macular hole surgery"
    Hasegawa, Yuhei
    Hata, Yasauki
    Mochizuki, Yasutaka
    Arita, Ryoichi
    Kawahara, Shuhei
    Kita, Takeshi
    Noda, Yoshihiro
    Ishibashi, Tatsuro
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) : 909 - 909
  • [48] Persistent outer retinal fluid following non-posturing surgery for idiopathic macular hole
    Rahman, Rubina
    Oxley, Lucy
    Stephenson, John
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (11) : 1451 - 1454
  • [49] Intraocular humidity immediately after fluid-air exchange in pars plana vitrectomy
    Eter, N
    Brinken, R
    Garbe, S
    Spitznas, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (03) : 305 - 308