Incomplete fluid-air exchange technique for idiopathic macular hole surgery

被引:1
|
作者
Hu, Bo Jie [1 ]
Du, Xue-Li [1 ]
Li, Wen-Bo [1 ]
Chang, Yu-Wen [2 ]
Shi, Xing-Dong [3 ]
Ma, Teng [1 ]
Wang, Yong [1 ]
He, Yan-Hua [1 ]
Niu, Rui [1 ]
Cui, Wei-Na [1 ]
机构
[1] Tianjin Med Univ, Dept Retina, Eye Hosp, 251 Fukang Rd, Tianjin 300384, Peoples R China
[2] Peoples Hosp Hetian Dist, Xinjiang 848000, Uygur Autonomou, Peoples R China
[3] Tianjin First Cent Hosp, Dept Ophthalmol, Tianjin 300192, Peoples R China
关键词
best-corrected visual acuity; electroretinography; internal limiting membrane; macular hole; fluid-air exchange; visual field defect; VISUAL-FIELD LOSS; PARS-PLANA VITRECTOMY; VITREOUS SURGERY; OUTCOMES; DEFECTS; INFUSION;
D O I
10.18240/ijo.2019.10.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To explore an improved procedure involving incomplete fluid-air exchange for idiopathic macular hole (IMH), and the closure rate, visual function, and the visual field of macular holes (MHs) were evaluated. METHODS: This prospective randomized controlled study, included 40 eyes of 40 patients with IMH who were treated with pars plana vitrectomy and peeling of the internal limiting membrane. They were grouped by random digital table. Twenty-one eyes underwent incomplete fluidair exchange (IFA) and 19 eyes underwent traditional complete fluid-air exchange (CFA) as the control group. Outcomes included best-corrected visual acuity (BCVA), intraocular pressure, and optical coherence tomography, light adaptive electroretinography, and visual field evaluations. RESULTS: All MHs <400 mu m were successfully closed. BCVAs before and 6mo after surgery were 0.82 +/- 0.41 logMAR and 0.28 +/- 0.17 logMAR in IFA group and 0.86 +/- 0.34 logMAR and 0.34 +/- 0.23 log MAR in CFA group, respectively. The electroretinogram analysis of patients in IFA group revealed increases in b-wave amplitudes at 1, 3, and 6mo after surgery. Additionally, patients in IFA group showed an amplitude increase of 28.6% from baseline at 6mo (P<0.05), while no obvious improvements were noted in CFA group. Although there were no statistically significant improvements in either group, the IFA group showed a slight increase in mean sensitivity (P>0.05). CONCLUSION: IFA is a reliable method that offers comparable closure rate to CFA and facilitates improvements in visual function.
引用
收藏
页码:1582 / 1588
页数:7
相关论文
共 50 条
  • [21] Modified technique of internal limiting membrane staining in idiopathic macular hole surgery
    Samir Mohamed El-Baha
    Mahmoud Alaa Abouhussein
    International Ophthalmology, 2019, 39 : 557 - 562
  • [22] Modified technique of internal limiting membrane staining in idiopathic macular hole surgery
    El-Baha, Samir Mohamed
    Abouhussein, Mahmoud Alaa
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (03) : 557 - 562
  • [23] Visual field defects after vitrectomy with fluid-air exchange
    Kokame, GT
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (05) : 653 - 654
  • [24] Use of air in macular hole surgery
    Gupta, Deepak
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) : 907 - 908
  • [25] Repeat fluid-gas exchange for failed primary macular hole surgery
    Goel, Neha
    Prakash, Abhinav
    Gupta, A. K.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (11) : 1104 - 1105
  • [26] Use of air in macular hole surgery
    Deepak Gupta
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 907 - 908
  • [27] Macular hole surgery with air tamponade
    Gesser, C.
    Eckert, T.
    Eckardt, U.
    Porkert, U.
    Eckardt, C.
    OPHTHALMOLOGE, 2010, 107 (11): : 1043 - +
  • [28] Subtotal vitrectomy in idiopathic macular hole surgery
    Tarakcioglu, Hatice Nur
    Tulu, Beril
    Ozkaya, Abdullah
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2019, 33 (04) : 369 - 373
  • [29] Macular changes following vitreous surgery for idiopathic macular hole
    Haritoglou, C
    Feix, CA
    Schaumberger, M
    Bengisu, M
    Ludwig, K
    Messmer, EM
    Kampik, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S340 - S340
  • [30] Effect of humidity on posterior lens opacification during fluid-air exchange
    Harlan, JB
    Lee, ET
    Jensen, PS
    de Juan, E
    ARCHIVES OF OPHTHALMOLOGY, 1999, 117 (06) : 802 - 804