Incomplete fluid-air exchange technique for idiopathic macular hole surgery

被引:1
|
作者
Hu, Bo Jie [1 ]
Du, Xue-Li [1 ]
Li, Wen-Bo [1 ]
Chang, Yu-Wen [2 ]
Shi, Xing-Dong [3 ]
Ma, Teng [1 ]
Wang, Yong [1 ]
He, Yan-Hua [1 ]
Niu, Rui [1 ]
Cui, Wei-Na [1 ]
机构
[1] Tianjin Med Univ, Dept Retina, Eye Hosp, 251 Fukang Rd, Tianjin 300384, Peoples R China
[2] Peoples Hosp Hetian Dist, Xinjiang 848000, Uygur Autonomou, Peoples R China
[3] Tianjin First Cent Hosp, Dept Ophthalmol, Tianjin 300192, Peoples R China
关键词
best-corrected visual acuity; electroretinography; internal limiting membrane; macular hole; fluid-air exchange; visual field defect; VISUAL-FIELD LOSS; PARS-PLANA VITRECTOMY; VITREOUS SURGERY; OUTCOMES; DEFECTS; INFUSION;
D O I
10.18240/ijo.2019.10.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To explore an improved procedure involving incomplete fluid-air exchange for idiopathic macular hole (IMH), and the closure rate, visual function, and the visual field of macular holes (MHs) were evaluated. METHODS: This prospective randomized controlled study, included 40 eyes of 40 patients with IMH who were treated with pars plana vitrectomy and peeling of the internal limiting membrane. They were grouped by random digital table. Twenty-one eyes underwent incomplete fluidair exchange (IFA) and 19 eyes underwent traditional complete fluid-air exchange (CFA) as the control group. Outcomes included best-corrected visual acuity (BCVA), intraocular pressure, and optical coherence tomography, light adaptive electroretinography, and visual field evaluations. RESULTS: All MHs <400 mu m were successfully closed. BCVAs before and 6mo after surgery were 0.82 +/- 0.41 logMAR and 0.28 +/- 0.17 logMAR in IFA group and 0.86 +/- 0.34 logMAR and 0.34 +/- 0.23 log MAR in CFA group, respectively. The electroretinogram analysis of patients in IFA group revealed increases in b-wave amplitudes at 1, 3, and 6mo after surgery. Additionally, patients in IFA group showed an amplitude increase of 28.6% from baseline at 6mo (P<0.05), while no obvious improvements were noted in CFA group. Although there were no statistically significant improvements in either group, the IFA group showed a slight increase in mean sensitivity (P>0.05). CONCLUSION: IFA is a reliable method that offers comparable closure rate to CFA and facilitates improvements in visual function.
引用
收藏
页码:1582 / 1588
页数:7
相关论文
共 50 条
  • [1] Incomplete fluid-air exchange technique for idiopathic macular hole surgery
    Bo-Jie Hu
    Xue-Li Du
    Wen-Bo Li
    Yu-Wen Chang
    Xing-Dong Shi
    Teng Ma
    Yong Wang
    Yan-Hua He
    Rui Niu
    Wei-Na Cui
    International Journal of Ophthalmology, 2019, (10) : 1582 - 1588
  • [2] Prevention of visual field defect after macular hole surgery by passing air used for fluid-air exchange through water
    Ohji, M
    Nao-I, N
    Saito, Y
    Hayashi, A
    Tano, Y
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (01) : 62 - 66
  • [4] Prevention of visual field defect after macular hole surgery by passing air used for fluid-air exchange through water - Reply
    Ohji, M
    Okada, AA
    Tano, Y
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (03) : 397 - 397
  • [5] FLUID-AIR EXCHANGE
    MATHIS, A
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1992, 15 (05): : 367 - 371
  • [6] A MODIFIED TECHNIQUE FOR PERFORMING OUTPATIENT FLUID-AIR EXCHANGE FOLLOWING VITRECTOMY SURGERY
    MILLER, JA
    CHANDRA, SR
    STEVENS, TS
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1986, 101 (01) : 116 - 117
  • [7] INSTRUMENTATION FOR CONTINUOUS FLUID-AIR EXCHANGE DURING VITREOUS SURGERY
    HUENEKE, RL
    AABERG, TM
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1983, 96 (04) : 547 - 548
  • [8] VITREORETINAL SEPARATION AND FLUID-AIR EXCHANGE
    IBANEZ, HE
    BLOOM, SM
    OLK, RJ
    ARRIBAS, NP
    BONIUK, I
    GRAND, G
    THOMAS, M
    MAHL, C
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1995, 15 (05): : 448 - 448
  • [9] Prognostic factors in fluid–gas exchange after primary idiopathic macular hole surgery
    You Hyun Lee
    Soo Jin Lee
    Ji Hye Jang
    Yu Cheol Kim
    International Ophthalmology, 2022, 42 : 2811 - 2818
  • [10] NEW INSTRUMENTATION FOR FLUID-AIR EXCHANGE
    BRUCKER, AJ
    HOFFMAN, ME
    NEVYAS, HJ
    WULC, AE
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1983, 3 (02): : 135 - 136