Development of portable lymphatic flow assessment system for lymphatic filariasis

被引:0
|
作者
Chellammal, S [1 ]
Somayaji, KM
Panicker, TMR
Korath, MP
Jagadeesan, K
机构
[1] Indira Gandhi Ctr Atom Res, Dept Atom Energy, Radiol Safety Div, Kalpakkam 603102, Tamil Nadu, India
[2] KJ Hosp Res, KJ Res Fdn, Madras, Tamil Nadu, India
[3] Post Grad Ctr, Madras, Tamil Nadu, India
关键词
lymphatic flow assessment; filariasis; portable equipment; gamma camera;
D O I
10.1081/CI-200037014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The conventional gamma camera used for the assessment of lymphatic system, using the lymphoscintigraphy technique, is institution based and costly. Therefore, it is not easily accessible to people from remote rural areas. Hence, there is a need for economical and portable equipment to field survey disease-prone areas. Towards this objective, with the advent of developments in radioactivity detection techniques, knowledge-based instrumentation, computer technology, a versatile, cost-effective, portable microcontroller based scintillation detector equipment with a personal computer (PC) interface for the assessment of the lymphatic system has been designed and developed using a lymphoscintigraphy technique. Though the technique is conventional, the detection of radioactivity is unique, employing micro scintillation detectors in contrast to conventional gamma camera. In the latter case, a large diameter scintillation detector is allowed to scan the area of interest for a predetermined time to produce the trajectory of lymph flow as an analog image, whereas, the present instrument records numeric values of radioactivities at different locations and this digital data is automatically archived; this enables a physician friendly diagnosis. The prototype instrument was employed for testing patients and volunteers, and the performance of the instrument was inter-compared with simultaneous qualitative measurements made with a conventional gamma camera; it is found that the instrument is able to reproduce results. The indigenously developed cost-effective portable lymph flow assessment system is applicable for field survey and could replace the conventional gamma camera.
引用
收藏
页码:589 / 600
页数:12
相关论文
共 50 条
  • [41] Laos eliminates lymphatic filariasis
    Bagcchi, Sanjeet
    LANCET INFECTIOUS DISEASES, 2024, 24 (01): : e17 - e17
  • [42] Trouble in paradise: Lymphatic filariasis
    Kuo, M.
    Yeh, J.
    Choi, C.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2006, 21 : 277 - 278
  • [43] PATHOGENESIS OF LYMPHATIC FILARIASIS IN MAN
    CONNOR, DH
    PALMIERI, JR
    GIBSON, DW
    ZEITSCHRIFT FUR PARASITENKUNDE-PARASITOLOGY RESEARCH, 1986, 72 (01): : 13 - 28
  • [44] METRIFONATE IN ONCHOCERCIASIS AND LYMPHATIC FILARIASIS
    ABARU, DE
    MCMAHON, JE
    TROPENMEDIZIN UND PARASITOLOGIE, 1978, 29 (02): : 175 - 177
  • [45] Eliminating Lymphatic Filariasis: Is it Worth it?
    Niessen, Louis Wilhelmus
    Taylor, Mark L.
    CLINICAL INFECTIOUS DISEASES, 2020, 70 (12) : 2568 - 2569
  • [46] ABOUT LONGEVITY OF LYMPHATIC FILARIASIS
    BRUMPT, L
    MEDECINE ET MALADIES INFECTIEUSES, 1977, 7 (09): : 428 - 428
  • [47] LYMPHATIC NODULES IN HUMAN FILARIASIS
    KAR, SK
    LYMPHOLOGY, 1985, 18 (04) : 163 - 164
  • [48] IVERMECTIN AND HUMAN LYMPHATIC FILARIASIS
    KAZURA, JW
    MICROBIAL PATHOGENESIS, 1993, 14 (05) : 337 - 342
  • [49] PROTECTIVE IMMUNITY IN LYMPHATIC FILARIASIS
    NUTMAN, TB
    EXPERIMENTAL PARASITOLOGY, 1989, 68 (02) : 248 - 252
  • [50] Success against lymphatic filariasis
    Cao, WC
    VanderPloeg, CPB
    Ren, ZX
    Habbema, JDF
    WORLD HEALTH FORUM, 1997, 18 (01): : 17 - 20