摘要
The conventional gamma camera used for the assessment of lymphatic system, using the lymphoscintigraphy technique, is institution based and costly. Therefore, it is not easily accessible to people from remote rural areas. Hence, there is a need for economical and portable equipment to field survey disease-prone areas. Towards this objective, with the advent of developments in radioactivity detection techniques, knowledge-based instrumentation, computer technology, a versatile, cost-effective, portable microcontroller based scintillation detector equipment with a personal computer (PC) interface for the assessment of the lymphatic system has been designed and developed using a lymphoscintigraphy technique. Though the technique is conventional, the detection of radioactivity is unique, employing micro scintillation detectors in contrast to conventional gamma camera. In the latter case, a large diameter scintillation detector is allowed to scan the area of interest for a predetermined time to produce the trajectory of lymph flow as an analog image, whereas, the present instrument records numeric values of radioactivities at different locations and this digital data is automatically archived; this enables a physician friendly diagnosis. The prototype instrument was employed for testing patients and volunteers, and the performance of the instrument was inter-compared with simultaneous qualitative measurements made with a conventional gamma camera; it is found that the instrument is able to reproduce results. The indigenously developed cost-effective portable lymph flow assessment system is applicable for field survey and could replace the conventional gamma camera.
引用
收藏
页码:589 / 600
页数:12
相关论文
共 50 条
  • [21] Albendazole for lymphatic filariasis
    Critchley, J.
    Addiss, D.
    Gamble, C.
    Garner, P.
    Gelband, H.
    Ejere, H.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2005, (04):
  • [22] Elimination of lymphatic filariasis
    Michael, Edwin
    Malecela-Lazaro, Mwele N.
    Kazura, James W.
    LANCET, 2006, 368 (9533): : 362 - 363
  • [23] IVERMECTIN IN LYMPHATIC FILARIASIS
    MAREN, TH
    NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (13): : 917 - 917
  • [24] Urban lymphatic filariasis
    Paul E. Simonsen
    Mbutolwe E. Mwakitalu
    Parasitology Research, 2013, 112 : 35 - 44
  • [25] LONGEVITY OF LYMPHATIC FILARIASIS
    CARME, B
    PICHON, G
    MERLIN, M
    LAIGRET, J
    MEDECINE ET MALADIES INFECTIEUSES, 1977, 7 (10): : 471 - 472
  • [26] Elimination of lymphatic filariasis
    Gogia, S. B.
    Sathi
    Sangtin
    NATIONAL MEDICAL JOURNAL OF INDIA, 2016, 29 (01): : 37 - 37
  • [27] Urban lymphatic filariasis
    Simonsen, Paul E.
    Mwakitalu, Mbutolwe E.
    PARASITOLOGY RESEARCH, 2013, 112 (01) : 35 - 44
  • [28] Immunology of lymphatic filariasis
    Babu, S.
    Nutman, T. B.
    PARASITE IMMUNOLOGY, 2014, 36 (08) : 338 - 346
  • [29] Mediastinal lymphatic filariasis
    Soulard, R
    Guigay, J
    de Kerangal, XL
    Saint-Blancard, P
    ANNALES DE PATHOLOGIE, 2001, 21 (05) : 431 - 434
  • [30] EPIDEMIOLOGY OF LYMPHATIC FILARIASIS
    MAK, JW
    CIBA FOUNDATION SYMPOSIA, 1987, 127 : 5 - 14