Development of portable lymphatic flow assessment system for lymphatic filariasis

被引:0
|
作者
Chellammal, S [1 ]
Somayaji, KM
Panicker, TMR
Korath, MP
Jagadeesan, K
机构
[1] Indira Gandhi Ctr Atom Res, Dept Atom Energy, Radiol Safety Div, Kalpakkam 603102, Tamil Nadu, India
[2] KJ Hosp Res, KJ Res Fdn, Madras, Tamil Nadu, India
[3] Post Grad Ctr, Madras, Tamil Nadu, India
关键词
lymphatic flow assessment; filariasis; portable equipment; gamma camera;
D O I
10.1081/CI-200037014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The conventional gamma camera used for the assessment of lymphatic system, using the lymphoscintigraphy technique, is institution based and costly. Therefore, it is not easily accessible to people from remote rural areas. Hence, there is a need for economical and portable equipment to field survey disease-prone areas. Towards this objective, with the advent of developments in radioactivity detection techniques, knowledge-based instrumentation, computer technology, a versatile, cost-effective, portable microcontroller based scintillation detector equipment with a personal computer (PC) interface for the assessment of the lymphatic system has been designed and developed using a lymphoscintigraphy technique. Though the technique is conventional, the detection of radioactivity is unique, employing micro scintillation detectors in contrast to conventional gamma camera. In the latter case, a large diameter scintillation detector is allowed to scan the area of interest for a predetermined time to produce the trajectory of lymph flow as an analog image, whereas, the present instrument records numeric values of radioactivities at different locations and this digital data is automatically archived; this enables a physician friendly diagnosis. The prototype instrument was employed for testing patients and volunteers, and the performance of the instrument was inter-compared with simultaneous qualitative measurements made with a conventional gamma camera; it is found that the instrument is able to reproduce results. The indigenously developed cost-effective portable lymph flow assessment system is applicable for field survey and could replace the conventional gamma camera.
引用
收藏
页码:589 / 600
页数:12
相关论文
共 50 条
  • [1] The development of albendazole for lymphatic filariasis
    Horton, J.
    ANNALS OF TROPICAL MEDICINE AND PARASITOLOGY, 2009, 103 : S33 - S40
  • [2] Lymphatic filariasis
    Rajan, TV
    Gundlapalli, AV
    IMMUNOPATHOGENETIC ASPECTS OF DISEASE INDUCED BY HELMINTH PARASITES, 1997, 66 : 125 - 158
  • [3] Lymphatic Filariasis
    Lourens, Gayle B.
    Ferrell, Denise K.
    NURSING CLINICS OF NORTH AMERICA, 2019, 54 (02) : 181 - +
  • [4] LYMPHATIC FILARIASIS
    不详
    WHO TECHNICAL REPORT SERIES, 1984, (702) : 7 - 112
  • [5] LYMPHATIC FILARIASIS
    EWERT, A
    FOLSE, D
    AMERICAN JOURNAL OF PATHOLOGY, 1984, 115 (01): : 135 - 137
  • [6] Lymphatic filariasis
    不详
    TROPICAL DOCTOR, 1999, 29 (01) : 57 - 57
  • [7] Lymphatic Filariasis
    Madanchi, Matiar
    Itin, Peter
    NEW ENGLAND JOURNAL OF MEDICINE, 2024, 390 (18): : E43 - E43
  • [8] Rapid assessment procedures (RAP) for lymphatic filariasis
    Pani, SP
    Srividya, A
    Krishnamoorthy, K
    Das, PK
    Dhanda, V
    NATIONAL MEDICAL JOURNAL OF INDIA, 1997, 10 (01): : 19 - 22
  • [9] Advances in Vaccine Development for Human Lymphatic Filariasis
    Kalyanasundaram, Ramaswamy
    Khatri, Vishal
    Chauhan, Nikhil
    TRENDS IN PARASITOLOGY, 2020, 36 (02) : 195 - 205
  • [10] Lymphatic filariasis and onchocerciasis
    Taylor, Mark J.
    Hoerauf, Achim
    Bockarie, Moses
    LANCET, 2010, 376 (9747): : 1175 - 1185