Fractionated elution of 99Mo/99mTc generators using calibrated vials

被引:0
|
作者
Vigne, Jonathan [1 ,2 ,3 ,4 ]
Emery, Stephane [5 ]
Lemarie, Nicolas [5 ]
Chavent, Benedicte [5 ]
Hallouard, Francois [5 ]
Le Guludec, Dominique [1 ,2 ,3 ,4 ]
Rouzet, Francois [1 ,2 ,3 ,4 ]
Fraysse, Marc [5 ]
De Mil, Remy [6 ,7 ]
机构
[1] Hop Xavier Bichat, AP HP, Dept Nucl Med, Paris, France
[2] DHU Fire, Paris, France
[3] Univ Paris Diderot, Federat Rech Imagerie Multimodalite, UMS 34, Paris, France
[4] Hop Xavier Bichat, INSERM, Lab Vasc Translat Sci, UMR 1148,LVTS, Paris, France
[5] Hosp Civils Lyon, Grp Hosp Lyon Sud, Radiopharm Unit, Dept Pharm,Unite Radiopharm,Serv Pharm, Pierre Benite, France
[6] UCN, INSERM, ANTICIPE, U1086, Caen, France
[7] Univ Hosp Caen, Caen, France
关键词
Mo-99; Tc-99m generator; fractionated elution; nuclear pharmacy;
D O I
10.1097/MNM.0000000000000881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fractionated elution consists in collecting the fractions of an eluate with the highest radioactive concentration. It may be useful to meet the requirements of a subset of clinical radiopharmacy procedures. This study aims to describe and evaluate straightforward procedures allowing to readily perform fractionated elution on dry and wet columns Mo-99/Tc-99m generators by using calibrated vials. The main objectives of this study consisted in determining the relationship between eluate volume and elution yield using different vials calibration and assessing repeatability of the procedure. Elution vials were calibrated to obtain different eluate volumes by addition of air for wet column generator (WCG) and subtraction of saline for dry column generator (DCG) (n5 for each calibration). The relationship between the eluate volume and the elution yield was determined by a regression model for both DCG and WCG. Then repeatability evaluation was performed using 3-ml vial calibration. Relationships between the eluate volume (V) and the elution yield (Y) for DCG and WCG were Y=57.551 ln(V)+10.526 and Y=50.256 ln(V)+17.597, respectively. For repeatability assessment (n=30 for DCG and n=31 for WCG), the median volume and the interquartile range for DCG and WCG were 2.98ml (2.92-3.01) and 3.28ml (2.71-3.40), respectively, and median (interquartile range) eluate yields were 84.73% (81.30-86.33) and 81.78% (78.91-85.20), respectively. The volume was significantly higher for WCG than DCG (P=0.036) and also significantly more variable (P<0.001). The elution yield was significantly lower for WCG than DCG (P=0.025), but no difference in variability between the two generators was found (P=0.874). Easy-to-handle fractionated elution methods are compatible with both DCG and WCG. Fractionation using calibrated vials exhibits a better reproducibility with DCG than WCG generators and represents the only proposed method so far to master fractionated elution with DCG.
引用
收藏
页码:865 / 869
页数:5
相关论文
共 50 条
  • [41] Accelerator based 99Mo/99mTc production activity in Armenia
    Avagyan, R.
    Avetisyan, A.
    Kerobyan, I.
    Dallakyan, R.
    NUCLEAR MEDICINE AND BIOLOGY, 2014, 41 (07) : 648 - 649
  • [42] Separation of 99Mo and 99mTc by liquid–liquid extraction using trioctylamine as extractant
    Moumita Maiti
    Susanta Lahiri
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 283 : 661 - 663
  • [43] ANALYSES ON PRODUCTION OF 99Mo AND 99mTc ISOTOPES FOR NUCLEAR MEDICINE
    Nikolaichuk, L. I.
    Popov, V. A.
    Tutubalin, A. I.
    Krivchenko, O. V.
    Shepelev, A. G.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2012, (04): : 160 - 162
  • [44] Standardization of 99mTc and 99Mo by the use of a 4πβ-4πγ counter
    Yamada, T.
    Sato, Y.
    Unno, Y.
    Yunoki, A.
    Hino, Y.
    Ishii, K.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1324 - 1329
  • [45] Purification of 99Mo and 99mTc from radioactive traces of Nb, Zr, and Y impurities: method applicable in the purification of the spent 100/99Mo–99mTc generator
    Sankha Chattopadhyay
    Sujata Saha Das
    Md. Nayer Madhusmita
    Sharmila Alam
    Journal of Radioanalytical and Nuclear Chemistry, 2019, 322 : 809 - 815
  • [46] Pharmaceutical grade sodium [99mTc] pertechnetate from low specific activity 99Mo using an automated 99Mo/99mTc-TCM-autosolex generator
    Sankha Chattopadhyay
    Luna Barua
    Sujata Saha Das
    Anirban De
    Umesh Kumar
    Arpit Mitra
    Tapas Mallick
    Md. Alam Madhusmita
    Samarendu Nayer
    Bharat Ratna Sinha
    Shantanu Sarkar
    Kakali Ganguly
    Malay Kanti De
    M. G. R. Das
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 781 - 790
  • [47] An Automated 99mTc Generator Device Using Low Specific Activity 99Mo
    Yang, Guogui
    Hu, Ji
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [48] Pharmaceutical grade sodium [99mTc] pertechnetate from low specific activity 99Mo using an automated 99Mo/99mTc-TCM-autosolex generator
    Chattopadhyay, Sankha
    Barua, Luna
    Das, Sujata Saha
    De, Anirban
    Kumar, Umesh
    Mitra, Arpit
    Mallick, Tapas
    Madhusmita
    Nayer, Md Alam
    Sinha, Samarendu
    Sarkar, Bharat Ratna
    Ganguly, Shantanu
    De, Kakali
    Das, Malay Kanti
    Rajan, M. G. R.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 302 (02) : 781 - 790
  • [49] CALCULATION OF 99Mo, 99MTc AND 99Tc IN THE GENERATOR AND IN THE ELUATE.
    Thieme, K.
    International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1988, 39 (03): : 267 - 268
  • [50] Molybdenum-99 (99Mo) Adsorption Profile of Zirconia-Based Materials for 99Mo/99mTc Generator Application
    Marlina
    Lestari, E.
    Abidin
    Hambali
    Saptiama, I
    Febriana, S.
    Kadarisman
    Awaludin, R.
    Tanase, M.
    Nishikata, K.
    Tsuchiya, K.
    ATOM INDONESIA, 2020, 46 (02) : 91 - 97