Fractionated elution of 99Mo/99mTc generators using calibrated vials

被引:0
|
作者
Vigne, Jonathan [1 ,2 ,3 ,4 ]
Emery, Stephane [5 ]
Lemarie, Nicolas [5 ]
Chavent, Benedicte [5 ]
Hallouard, Francois [5 ]
Le Guludec, Dominique [1 ,2 ,3 ,4 ]
Rouzet, Francois [1 ,2 ,3 ,4 ]
Fraysse, Marc [5 ]
De Mil, Remy [6 ,7 ]
机构
[1] Hop Xavier Bichat, AP HP, Dept Nucl Med, Paris, France
[2] DHU Fire, Paris, France
[3] Univ Paris Diderot, Federat Rech Imagerie Multimodalite, UMS 34, Paris, France
[4] Hop Xavier Bichat, INSERM, Lab Vasc Translat Sci, UMR 1148,LVTS, Paris, France
[5] Hosp Civils Lyon, Grp Hosp Lyon Sud, Radiopharm Unit, Dept Pharm,Unite Radiopharm,Serv Pharm, Pierre Benite, France
[6] UCN, INSERM, ANTICIPE, U1086, Caen, France
[7] Univ Hosp Caen, Caen, France
关键词
Mo-99; Tc-99m generator; fractionated elution; nuclear pharmacy;
D O I
10.1097/MNM.0000000000000881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fractionated elution consists in collecting the fractions of an eluate with the highest radioactive concentration. It may be useful to meet the requirements of a subset of clinical radiopharmacy procedures. This study aims to describe and evaluate straightforward procedures allowing to readily perform fractionated elution on dry and wet columns Mo-99/Tc-99m generators by using calibrated vials. The main objectives of this study consisted in determining the relationship between eluate volume and elution yield using different vials calibration and assessing repeatability of the procedure. Elution vials were calibrated to obtain different eluate volumes by addition of air for wet column generator (WCG) and subtraction of saline for dry column generator (DCG) (n5 for each calibration). The relationship between the eluate volume and the elution yield was determined by a regression model for both DCG and WCG. Then repeatability evaluation was performed using 3-ml vial calibration. Relationships between the eluate volume (V) and the elution yield (Y) for DCG and WCG were Y=57.551 ln(V)+10.526 and Y=50.256 ln(V)+17.597, respectively. For repeatability assessment (n=30 for DCG and n=31 for WCG), the median volume and the interquartile range for DCG and WCG were 2.98ml (2.92-3.01) and 3.28ml (2.71-3.40), respectively, and median (interquartile range) eluate yields were 84.73% (81.30-86.33) and 81.78% (78.91-85.20), respectively. The volume was significantly higher for WCG than DCG (P=0.036) and also significantly more variable (P<0.001). The elution yield was significantly lower for WCG than DCG (P=0.025), but no difference in variability between the two generators was found (P=0.874). Easy-to-handle fractionated elution methods are compatible with both DCG and WCG. Fractionation using calibrated vials exhibits a better reproducibility with DCG than WCG generators and represents the only proposed method so far to master fractionated elution with DCG.
引用
收藏
页码:865 / 869
页数:5
相关论文
共 50 条
  • [11] Determination of 99Mo contamination in 99mTc elute obtained from 99Mo/99mTc- generator
    Momennezhad, M.
    Zakavi, S. R.
    Sadeghi, R.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2010, 8 (01): : 31 - 35
  • [12] On the "artificial" nature of Tc and the "carrier-free" nature of 99mTc from 99Mo/99mTc generators.
    Alfassi, ZB
    Groppi, F
    Bonardi, ML
    de Goeij, JJM
    APPLIED RADIATION AND ISOTOPES, 2005, 63 (01) : 37 - 40
  • [13] RAPID DETERMINATION OF 99MO IN SEPARATED 99MTC
    RICHARDS, P
    OBRIEN, MJ
    JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (07) : 517 - &
  • [14] A novel electrochemical 99Mo/99mTc generator
    Chakravarty, Rubel
    Venkatesh, Meera
    Dash, Ashutosh
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 290 (01) : 45 - 51
  • [15] 99Mo/99mTc generators performances prepared from zirconium molybate gels
    Monroy-Guzman, Fabiola
    Diaz-Archundia, Laura Veronica
    Hernandez-Cortes, Sabino
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2008, 19 (03) : 380 - 388
  • [16] A novel electrochemical 99Mo/99mTc generator
    Rubel Chakravarty
    Meera Venkatesh
    Ashutosh Dash
    Journal of Radioanalytical and Nuclear Chemistry, 2011, 290
  • [17] Long-lived γ-radionuclidic impurities in spent 99Mo/99mTc generators
    Vucina, J.L.
    Markovic, M.M.
    Kukoc, A.H.
    Journal of Radioanalytical and Nuclear Chemistry, 1996, 212 (03): : 221 - 227
  • [18] Diversification of 99Mo/99mTc Separation: Non-Fission Reactor Production of 99Mo as a Strategy for Enhancing 99mTc Availability
    Pillai, Maroor R. A.
    Dash, Ashutosh
    Knapp, Furn F. , Jr.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 159 - 161
  • [19] Comparative assessment of nanostructured metal oxides for preparation of clinically useful 99Mo/99mTc generators using low specific activity 99Mo
    Chakravarty, Rubel
    Dash, Ashutosh
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [20] Excitation functions for the cyclotron production of 99mTc and 99Mo
    Scholten, B
    Lambrecht, RM
    Cogneau, M
    Ruiz, HV
    Qaim, SM
    APPLIED RADIATION AND ISOTOPES, 1999, 51 (01) : 69 - 80