Fractionated elution of 99Mo/99mTc generators using calibrated vials

被引:0
|
作者
Vigne, Jonathan [1 ,2 ,3 ,4 ]
Emery, Stephane [5 ]
Lemarie, Nicolas [5 ]
Chavent, Benedicte [5 ]
Hallouard, Francois [5 ]
Le Guludec, Dominique [1 ,2 ,3 ,4 ]
Rouzet, Francois [1 ,2 ,3 ,4 ]
Fraysse, Marc [5 ]
De Mil, Remy [6 ,7 ]
机构
[1] Hop Xavier Bichat, AP HP, Dept Nucl Med, Paris, France
[2] DHU Fire, Paris, France
[3] Univ Paris Diderot, Federat Rech Imagerie Multimodalite, UMS 34, Paris, France
[4] Hop Xavier Bichat, INSERM, Lab Vasc Translat Sci, UMR 1148,LVTS, Paris, France
[5] Hosp Civils Lyon, Grp Hosp Lyon Sud, Radiopharm Unit, Dept Pharm,Unite Radiopharm,Serv Pharm, Pierre Benite, France
[6] UCN, INSERM, ANTICIPE, U1086, Caen, France
[7] Univ Hosp Caen, Caen, France
关键词
Mo-99; Tc-99m generator; fractionated elution; nuclear pharmacy;
D O I
10.1097/MNM.0000000000000881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fractionated elution consists in collecting the fractions of an eluate with the highest radioactive concentration. It may be useful to meet the requirements of a subset of clinical radiopharmacy procedures. This study aims to describe and evaluate straightforward procedures allowing to readily perform fractionated elution on dry and wet columns Mo-99/Tc-99m generators by using calibrated vials. The main objectives of this study consisted in determining the relationship between eluate volume and elution yield using different vials calibration and assessing repeatability of the procedure. Elution vials were calibrated to obtain different eluate volumes by addition of air for wet column generator (WCG) and subtraction of saline for dry column generator (DCG) (n5 for each calibration). The relationship between the eluate volume and the elution yield was determined by a regression model for both DCG and WCG. Then repeatability evaluation was performed using 3-ml vial calibration. Relationships between the eluate volume (V) and the elution yield (Y) for DCG and WCG were Y=57.551 ln(V)+10.526 and Y=50.256 ln(V)+17.597, respectively. For repeatability assessment (n=30 for DCG and n=31 for WCG), the median volume and the interquartile range for DCG and WCG were 2.98ml (2.92-3.01) and 3.28ml (2.71-3.40), respectively, and median (interquartile range) eluate yields were 84.73% (81.30-86.33) and 81.78% (78.91-85.20), respectively. The volume was significantly higher for WCG than DCG (P=0.036) and also significantly more variable (P<0.001). The elution yield was significantly lower for WCG than DCG (P=0.025), but no difference in variability between the two generators was found (P=0.874). Easy-to-handle fractionated elution methods are compatible with both DCG and WCG. Fractionation using calibrated vials exhibits a better reproducibility with DCG than WCG generators and represents the only proposed method so far to master fractionated elution with DCG.
引用
收藏
页码:865 / 869
页数:5
相关论文
共 50 条
  • [1] Effect of Al:Mo molar ratio on elution performance of 99Mo/99mTc generators based on Al99Mo gels
    M. Amin
    E. A. Abdel-Galil
    W. M. El-Kenany
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 309 : 485 - 492
  • [2] Effect of Al:Mo molar ratio on elution performance of 99Mo/99mTc generators based on Al99Mo gels
    Amin, M.
    Abdel-Galil, E. A.
    El-Kenany, W. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 309 (02) : 485 - 492
  • [3] Study of the influence of the first elution from generators 99Mo/99mTc in the radiochemical purity of radiopharmaceuticals preparations
    Diaz Alarcon, J. P.
    Palacios Gerona, H.
    Urena Lara, M. J.
    Cepedello Boiso, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S415 - S415
  • [4] Desorption of 99Mo from spent 99Mo/99mTc generator
    Mushtaq, A.
    Journal of Radioanalytical and Nuclear Chemistry, 199 (02):
  • [5] Desorption of 99Mo from spent 99Mo/99mTc generator
    Radioisotope Production Group, Nuclear Chemistry Division, PINTECH, PO Nilore, Islamabad, Pakistan
    J. RADIOANAL. NUCL. CHEM., 2 (89-94):
  • [6] Diversification of 99Mo/99mTc Supply
    Dick, David
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (06) : 875 - 876
  • [7] Mechanism of 99Mo adsorption and 99mTc elution from zirconium-based material in 99Mo/99mTc generator column using neutron-irradiated natural molybdenum
    Awaludin, Rohadi
    Gunawan, AdangHardi
    Lubis, Hotman
    Sriyono
    Herlina
    Mutalib, Abdul
    Kimura, Akihiro
    Tsuchiya, Kunihiko
    Tanase, Masakazu
    Ishihara, Masahiro
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 303 (02) : 1481 - 1483
  • [8] β-MoO3 Whiskers in 99Mo/99mTc Radioisotope Production and 99Mo/99mTc Extraction Using Hot Atoms
    Ngo, Minh Chu
    Fujita, Yoshitaka
    Suzuki, Tatsuya
    Do, Thi Mai Dung
    Seki, Misaki
    Nakayama, Tadachika
    Niihara, Koichi
    Suematsu, Hisayuki
    INORGANIC CHEMISTRY, 2023, 62 (32) : 13140 - 13147
  • [9] Evaluation of Pakgen 99mTc generators loaded with indigenous fission 99Mo
    Mushtaq, A.
    Pervez, S.
    Hussain, S.
    Mirza, J. A.
    Khan, M. M.
    Asif, M.
    Siddique, M. U.
    Khalid, U.
    Khan, B.
    Khalid, M.
    RADIOCHIMICA ACTA, 2012, 100 (10) : 793 - 800
  • [10] Mechanism of 99Mo adsorption and 99mTc elution from zirconium-based material in 99Mo/ 99mTc generator column using neutron-irradiated natural molybdenum
    Rohadi Awaludin
    AdangHardi Gunawan
    Hotman Lubis
    Abdul Sriyono
    Akihiro Herlina
    Kunihiko Mutalib
    Masakazu Kimura
    Masahiro Tsuchiya
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 303 : 1481 - 1483