Influence of ambient temperatures on performance of a CO2 heat pump water heating system

被引:59
|
作者
Yokoyama, Ryohei
Shimizu, Takeshi
Ito, Koichi
Takemura, Kazuhisa
机构
[1] Osaka Prefecture Univ, Dept Mech Engn, Naka Ku, Sakai, Osaka 5998531, Japan
[2] Waseda Univ, Adv Res Inst Sci & Engn, Shinjuku Ku, Tokyo 1698555, Japan
[3] Kansai Elect Power Co Inc, Dept Res & Dev, Amagasaki, Hyogo 6610974, Japan
关键词
heat pump; refrigerant; CO2; thermal storage; system performance; thermodynamics; cycle analysis; numerical simulation;
D O I
10.1016/j.energy.2006.06.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
In residential applications, an air-to-water CO, heat pump is used in combination with a domestic hot water storage tank, and the performance of this system is affected significantly not only by instantaneous ambient air and city water temperatures but also by hourly changes of domestic hot water consumption and temperature distribution in the storage tank. In this paper, the performance of a CO2 heat pump water heating system is analyzed by numerical simulation. A simulation model is created based on thermodynamic equations, and the values of model parameters are estimated based on measured data for existing devices. The calculated performance is compared with the measured one, and the simulation model is validated. The system performance is clarified in consideration of seasonal changes of ambient air and city water temperatures. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:388 / 398
页数:11
相关论文
共 50 条
  • [41] Modified transcritical CO2 heat pump system with new water flow configuration for residential space heating
    He, Yu-Jia
    Cheng, Jia-Hao
    Chang, Meng-Meng
    Zhang, Chun-Lu
    ENERGY CONVERSION AND MANAGEMENT, 2021, 230
  • [42] Modelling the performance of a transcritical CO2 heat pump for high temperature heating (Reprinted)
    White, SD
    Yarrall, MG
    Cleland, DJ
    Hedley, RA
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (04): : 479 - 486
  • [43] Research of variable frequency performance of CO2 air source heat pump on heating
    Chen, Zidan
    Luo, Huilong
    Du, Peijian
    Liu, Jinchun
    Xue, Tao
    Zhao, Xinshuai
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (03): : 219 - 225
  • [44] Experimental study on the heating performance of transcritical CO2 heat pump for electric buses
    Chen, Shangmai
    Yang, Wei
    Wu, Haimei
    Deng, Rongbin
    Li, Tao
    Guo, Yang
    Jin, Zunlong
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (01) : 65 - 74
  • [45] The performance of a solar assisted heat pump water heating system
    Hawlader, MNA
    Chou, SK
    Ullah, MZ
    APPLIED THERMAL ENGINEERING, 2001, 21 (10) : 1049 - 1065
  • [46] Study on performance evaluation of CO2 heat pump system integrated with thermal energy storage for space heating
    Wang, Zhihua
    Zheng, Yuxin
    Wang, Fenghao
    Song, Mengjie
    Ma, Zhenjun
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 1380 - 1387
  • [47] Performance Optimization and Economic Evaluation of CO2 Heat Pump Heating System Coupled with Thermal Energy Storage
    Wang, Zhihua
    Zhang, Yujia
    Wang, Fenghao
    Li, Guichen
    Xu, Kaiwen
    SUSTAINABILITY, 2021, 13 (24)
  • [48] Experimental investigation of refrigerant charge determination for heating performance in a CO2 heat pump system for electric vehicles
    Li, Gang
    Ma, Jianwei
    Zou, Huiming
    Zhang, Rongrong
    APPLIED THERMAL ENGINEERING, 2023, 233
  • [49] CHARACTERISTICS AND PERFORMANCE OF A CO2 TRANS-CRITICAL WATER TO WATER HEAT PUMP
    Maina, Paul
    Huan, Zhongjie
    2013 PROCEEDINGS OF THE 10TH CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2013,
  • [50] EJECTOR CO2 HEAT PUMP FOR SPACE HEATING AND COOLING
    Minetto, Silvia
    Condotta, Marco
    Rossetti, Antonio
    Girotto, Sergio
    Del Col, Davide
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 463 - 470