Experimental investigation of refrigerant charge determination for heating performance in a CO2 heat pump system for electric vehicles

被引:3
|
作者
Li, Gang [1 ,2 ]
Ma, Jianwei [3 ]
Zou, Huiming [3 ]
Zhang, Rongrong [1 ]
机构
[1] Zhejiang Sanhua Automot Components Co Ltd, Hangzhou 310018, Peoples R China
[2] Shanghai Sanhua Elect Co Ltd, Shanghai 201204, Peoples R China
[3] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Sci & Technol Space Energy Convers, Beijing 100190, Peoples R China
关键词
CO2; Charge determination; Valve opening; Climate condition; Compressor speed; Electric vehicle;
D O I
10.1016/j.applthermaleng.2023.121147
中图分类号
O414.1 [热力学];
学科分类号
摘要
Given the scarcity of investigation of refrigerant charge for the heating performance of the CO2 automotive heat pump system, a test of charge determination with a 350-650 g range over a wide operating condition is comprehensively conducted. It is concluded that 450-550 g charge can be an appropriate level. The inefficient charge level is more sensitive for performance deterioration than the excessive level. Each refrigerant charge level can generate-30 kg/h mass flow rate lift, and more than 50 K discharge temperature increase in respect of the valve openings. Lifting the compressor speed can generally decrease system coefficient of performance (COP) by-18% under-20 degrees C ambient and by-40% under 0 degrees C ambient, respectively. As to the discharge pressure concerning the control strategies, for a fixed compressor speed, the cabin side air supply temperature in general has a linear relationship (with a fixed value of slope) in respect of the discharge pressure for low discharge pressure domains (less than 70 bar), no matter what the valve settings are or which charge amount level we choose or what the ambient condition is. In addition, with a fixed compressor speed, under the same discharge pressure, with-20% refrigerant charge reduction from the appropriate level, the COP generally can be dropped by more than 12%, and the drop is more pronounced under high ambient conditions. What's more, for a fixed optimal valve setting with different compressor speeds, under the same discharge pressure,-20% refrigerant charge loss can provide more than 20% COP drop. This may be helpful for fault diagnosis of system performance deterioration when charge leakage is involved. The conclusions in this study can be served as the guidelines for automotive heat pump systems.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Experimental investigation on the heating performance of a CO2 heat pump system with intermediate cooling for electric vehicles
    Chen, Yiyu
    Zou, Huiming
    Dong, Junqi
    Wu, Jiang
    Xu, Hongbo
    Tian, Changqing
    [J]. APPLIED THERMAL ENGINEERING, 2021, 182
  • [2] Experimental investigation of cooling performance of a CO2 heat pump system with an integrated accumulator heat exchanger for electric vehicles: Impact of refrigerant charge and valve opening
    Li, Gang
    Tang, Zuohang
    Zou, Huiming
    Zhang, Rongrong
    [J]. APPLIED THERMAL ENGINEERING, 2023, 224
  • [3] Experimental study on heating performance of a CO2 heat pump system for an electric bus
    Song, Xia
    Lu, Daxiong
    Lei, Qiang
    Cai, Yu
    Wang, Dandong
    Shi, Junye
    Chen, Jiangping
    [J]. APPLIED THERMAL ENGINEERING, 2021, 190
  • [4] Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles
    Li Kang
    Lan Jiao
    Zhou Guoliang
    Tang Qitian
    Cheng Qia
    Fang Yidong
    Su Lin
    [J]. JOURNAL OF THERMAL SCIENCE, 2019, 28 (02) : 294 - 305
  • [5] Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles
    LI Kang
    LAN Jiao
    ZHOU Guoliang
    TANG Qitian
    CHENG Qia
    FANG Yidong
    SU Lin
    [J]. Journal of Thermal Science, 2019, 28 (02) : 294 - 305
  • [6] Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles
    Kang Li
    Jiao Lan
    Guoliang Zhou
    Qitian Tang
    Qia Cheng
    Yidong Fang
    Lin Su
    [J]. Journal of Thermal Science, 2019, 28 : 294 - 305
  • [7] Experimental study on refrigerant charge amount and optimal high pressure of a CO2 heat pump system for an electric bus
    Guo, Yang
    Yang, Wei
    Wu, Haimei
    Li, Tao
    Chen, Shangmai
    Jin, Zunlong
    Deng, Rongbin
    [J]. JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2022, 14 (06)
  • [8] An experimental and theoretical investigation of refrigerant charge on a secondary loop air-conditioning heat pump system in electric vehicles
    Li, Kang
    Xu, Dan
    Lan, Jiao
    Su, Lin
    Fang, Yidong
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (08) : 3381 - 3398
  • [9] Experimental Investigation on Heating Performance of Newly Designed Air Source Heat Pump System for Electric Vehicles
    Li, Kang
    Yu, Jun
    Yu, Rong
    Su, Lin
    Fang, Yidong
    Yang, Zhongcheng
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2021, 13 (02)
  • [10] Experimental performance evaluation of heat pump by using CO2 as a refrigerant
    Venkatesh, V. K.
    Basavaraju, M. G.
    Rao, K. V. Sreenivas
    [J]. INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS AND MANUFACTURING APPLICATIONS (ICONAMMA-2016), 2016, 149