3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry

被引:153
|
作者
Mans, Anton [1 ]
Remeijer, Peter [1 ]
Olaciregui-Ruiz, Igor [1 ]
Wendling, Markus [1 ]
Sonke, Jan-Jakob [1 ]
Mijnheer, Ben [1 ]
van Herk, Marcel [1 ]
Stroom, Joep C. [1 ]
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
关键词
Portal dosimetry; Volumetric-modulated arc therapy; In vivo dosimetry; VIVO EPID DOSIMETRY; CONE-BEAM CT; TREATMENT DELIVERY; DOSE VERIFICATION; IMRT TREATMENTS; PROSTATE IMRT; CANCER; RADIOTHERAPY; ALGORITHM; GUIDANCE;
D O I
10.1016/j.radonc.2009.12.020
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To demonstrate the feasibility of back-projection portal dosimetry for accurate 3D dosimetric verification of volumetric-modulated arc therapy (VMAT), pre-treatment as well as in vivo. Materials and methods: Several modifications to our existing approach were implemented to make the method applicable to VMAT: (i) gantry angle-resolved data acquisition, (ii) calculation of the patient transmission, (iii) compensation for detector 'flex' and (iv) 3D dose reconstruction and evaluation. Results: Planned and EPID-(Electronic Portal Image Detector)-reconstructed close distributions show good agreement for pre-treatment verification of two prostate, a stereotactic lung and a head-and-neck VMAT plan and for in vivo verification of VMAT treatments of prostate and lung cancer. Averaged over pre-treatment verifications, planned and measured isocentre dose ratios were -1.2% (range [-4.7%,1.8%]). 3D gamma analysis (3% maximum dose, 3 mm) revealed mean gamma <gamma(mean)> = 0.37 [0.34,0.39], maximum 1% gamma (gamma(1%)) = 0.72 [0.66,0.81] and percentage of points with -gamma <= 1 < P(gamma <= 1)> = 99% [97%,100%.] For in vivo verification, the average isocentre dose ratio was -1.2% [-0.8%,-1.7%], <gamma(mean)> = 0.52 [0.40,0.64], <gamma(1%)> = 0.92 [0.76,1.08] and < P(gamma <= 1)> = 96% [93%,100%]. Conclusions: Our portal dosimetry method was successfully adapted for verification of VMAT treatments, pre-treatment as well as in vivo. (C) 2010 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 94 (2010) 181-187
引用
收藏
页码:181 / 187
页数:7
相关论文
共 50 条
  • [31] Retrospective analysis of portal dosimetry pre-treatment quality assurance of prostate volumetric-modulated arc therapy (VMAT) plans
    Maraghechi, Borna
    Davis, Jack
    Badu, Shyam
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 44 - 52
  • [32] Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
    Mizuno, Tomoki
    Tomita, Natsuo
    Takaoka, Taiki
    Tomida, Masashi
    Fukuma, Hiroshi
    Tsuchiya, Takahiro
    Shibamoto, Yuta
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [33] Exit fluence analysis using portal dosimetry in volumetric modulated arc therapy
    Sukumar, Prabakar
    Padmanaban, Sriram
    Rajasekaran, Dhanabalan
    Kannan, Muniyappan
    Nagarajan, Vivekanandan
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2012, 17 (06) : 324 - 331
  • [34] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [35] Evaluation of the sensitivity of two 3D diode array dosimetry systems to setup error for quality assurance (QA) of volumetric-modulated arc therapy (VMAT)
    Li, Guangjun
    Bai, Sen
    Chen, Nianyong
    Henderson, Lansdale
    Wu, Kui
    Xiao, Jianghong
    Zhang, Yingjie
    Jiang, Qingfeng
    Jiang, Xiaoqin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (05): : 13 - 24
  • [36] 3D Dosimetry for Volumetric Modulated Arc Stereotactic Delivery Using Compass
    Vikraman, S.
    Manigandan, D.
    Mohanraj, U.
    Karrthick, K.
    Karthikeyan, N.
    Saranganathan, B.
    Sambasivaselli, R.
    Senniandavar, V.
    Sathiyaraj, P.
    Tejinder, K.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Scalp Volumetric Modulated Arc Therapy Using 3D Milled Bolus: Dosimetry, Toxicity and Outcome
    Dibs, K.
    Konieczkowski, D. J.
    Grecula, J. C.
    Mitchell, D. L.
    Baliga, S.
    Gogineni, E.
    Barve, R.
    Jhawar, S. R.
    Zoller, W.
    Gamez, M. E.
    Blakaj, D. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E292 - E293
  • [38] Dosimetric comparison between jaw tracking and static jaw modes in volumetric-modulated arc therapy
    Hsieh, Y. T.
    Chou, C. Y.
    Huang, B. S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S880 - S880
  • [39] Dosimetric comparison between volumetric-modulated arc therapy and a hybrid volumetric-modulated arc therapy and segmented field-in-field technique for postmastectomy chest wall and regional lymph node irradiation
    Lang, Karen
    Loritz, Brianne
    Schwartz, Adam
    Hunzeker, Ashley
    Lenards, Nishele
    Culp, Lee
    Finley, Randi
    Corbin, Kimberly S.
    MEDICAL DOSIMETRY, 2020, 45 (02) : 121 - 127
  • [40] Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer
    Miura, Hideharu
    Fujiwara, Masayuki
    Tanooka, Masao
    Doi, Hiroshi
    Inoue, Hiroyuki
    Takada, Yasuhiro
    Kamikonya, Norihiko
    Hirota, Shozo
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (05) : 785 - 790