Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer

被引:9
|
作者
Miura, Hideharu [1 ]
Fujiwara, Masayuki [1 ]
Tanooka, Masao [1 ]
Doi, Hiroshi [1 ]
Inoue, Hiroyuki [1 ]
Takada, Yasuhiro [1 ]
Kamikonya, Norihiko [1 ]
Hirota, Shozo [1 ]
机构
[1] Hyogo Coll Med, Dept Radiol, Nishinomiya, Hyogo 6638501, Japan
关键词
Volumetric-modulated arc therapy; gantry acceleration; gantry angle error; planning study; maxillary cancer; IMRT; RADIOTHERAPY;
D O I
10.1093/jrr/rrs031
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We compared the efficiency and accuracy of full-arc and half-arc volumetric-modulated arc therapy (VMAT) delivery for maxillary cancer. Plans for gantry rotation angles of 360 and 180 (full-arc and half-arc VMAT) were created for six maxillary cancer cases with the Monaco treatment planning system, and delivered using an Elekta Synergy linear accelerator. Full-arc and half-arc VMAT were compared with regard to homogeneity index (HI), conformity index (CI), mean dose to normal brain, total monitor units (MU), delivery times, root mean square (r.m.s.) gantry accelerations (degrees/s(2)), and rims. gantry angle errors (degrees). The half-arc VMAT plans achieved comparable HI and Cl to the full-arc plans. Mean doses to the normal brain and brainstem with the half-arc VMAT plans were on average 16% and 17% lower than those with the full-arc VMAT plans. For other organs at risk (OARs), no significant DVH differences were observed between plans. Half-arc VMAT resulted in 11% less total MU and 20% shorter delivery time than the full-arc VMAT, while r.m.s. gantry acceleration and rims. gantry angle error during half-arc VMAT delivery were 30% and 23% less than those during full-arc VMAT delivery, respectively. Furthermore, the half-arc VMAT plans were comparable with the full-arc plans regarding close homogeneity and conformity in maxillary cancer, and provided a statistical decrease in mean dose to OAR, total MU, delivery time and gantry angle error. Half-arc VMAT plans may be a suitable treatment option in radiotherapy for maxillary cancer.
引用
收藏
页码:785 / 790
页数:6
相关论文
共 50 条
  • [1] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [2] Dosimetric Evaluation of Volumetric-modulated Arc Therapy (Rapid Arc) for Primary Leiomyosarcoma in the Spine
    Wu, Yong-Zhong
    Jin, Fu
    Wang, Ying
    Zhou, Juan
    Wu, Li-Hua
    He, Guang-Lei
    Qiu, Da
    He, Ya-Nan
    Liu, Xian-Feng
    Zhong, Ming-Song
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (05) : 387 - 394
  • [3] A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT
    Stathakis, Sotirios
    Narayanasamy, Ganesh
    Licon, Anna Laura
    Myers, Pamela
    Li, Ying
    Crownover, Richard
    Papanikolaou, Niko
    [J]. JOURNAL OF BUON, 2019, 24 (02): : 838 - 843
  • [4] Dosimetric Effect of Jaw Tracking in Volumetric-Modulated Arc Therapy
    Thongsawad, Sangutid
    Khamfongkhruea, Chirasak
    Tannanonta, Chirapha
    [J]. JOURNAL OF MEDICAL PHYSICS, 2018, 43 (01) : 52 - 57
  • [5] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    [J]. MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [6] Dosimetric comparison of short and full arc in spinal PTV in volumetric-modulated arc therapy-based craniospinal irradiation
    Sarkar, Biplab
    Munshi, Anusheel
    Ganesh, Tharmarnadar
    Manikandan, Arjunan
    Mohanti, Bidhu K.
    [J]. MEDICAL DOSIMETRY, 2020, 45 (01) : 1 - 6
  • [7] Impact of Plan Complexity On the Delivery Accuracy and Dosimetric Accuracy of Volumetric-Modulated Arc Therapy
    Li, G.
    Li, Y.
    Wang, Q.
    Xiao, J.
    Bai, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2892 - 2892
  • [8] Dosimetric comparison of tomotherapy and volumetric-modulated arc therapy for children with neuroblastoma
    Liu, Xia
    Liu, Zhikai
    Pang, Tingtian
    Dong, Tingting
    Qiu, Jie
    [J]. PEDIATRIC INVESTIGATION, 2020, 4 (03) : 186 - 191
  • [9] Dosimetric comparison of tomotherapy and volumetric-modulated arc therapy for children with neuroblastoma
    Liu Xia
    Liu Zhikai
    Pang Tingtian
    Dong Tingting
    Qiu Jie
    [J]. 儿科学研究(英文), 2020, 04 (03) : 186 - 191
  • [10] Volumetric-modulated arc therapy for adjuvant treatment of endometrial cancer
    Cima, Simona
    Cima, S.
    Valli, M. C.
    Richetti, A.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1142 - 1143