Accuracy and stability of temperature probes for intracranial application

被引:11
|
作者
Alessandri, B
Hoelper, BM
Behr, R
Kempski, O
机构
[1] Johannes Gutenberg Univ Mainz, Dept Neurosurg, Inst Neurosurg Pathophysiol, D-55101 Mainz, Germany
[2] Univ Marburg, Acad Hosp, Klinikum Fulda, Dept Neurosurg, Fulda, Germany
关键词
temperature sensor; drift; accuracy; neurotrend; licox; Neurovent-p;
D O I
10.1016/j.jneumeth.2004.04.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Intracranial temperature measurement may play a pivotal role for prognosis and treatment of neurological and neurosurgical patients. For reliable clinical application, accurate temperature readings are therefore necessary. We present an independent in vitro study investigating the accuracy and stability of three temperature probes. Eight Neurovent-P Temp (RN), eight Licox temperature sensors (LT) and eight Neurotrend sensors (NT) were placed into a water bath. The temperature was increased in 3degreesC increments from 30 to 42degreesC before (accuracy test day 0) and after (accuracy test day 5) a long-term stability test run at 37+/-0.2degreesC. The accuracy tests revealed deviations of <0.25, <0.2 and >0.4degreesC for the RN, NT and LT probes, respectively, when compared to the reference measurement by a precision Pt100 temperature measuring instrument. All sensor types showed stable readings over the course of 120 h. The high variability of LT probes was due to a malfunctioning Licox monitor. Excluding these values reduced deviation below 0.21degreesC the standard deviation at each temperature step was below +/-0.08 (RN, NT) and +/-0.12 (LT), laying within the range provided by the manufacturer (RN, NT: +/-0.1; LT: +/-0.2). In general, RN, NT and LT temperature measurement is reliable, but malfunctioning parts may lead to false interpretation of temperature readings. Therefore, validation of temperature probes to a reference temperature prior to clinical use is recommended. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 50 条
  • [1] IMPROVED ACCURACY AND LINEARITY OF HALL PROBES AND THEIR APPLICATION TO LINKED SCANS
    TROTT, GW
    PORTER, CJ
    BEYNON, JH
    BRENTON, AG
    MORGAN, RP
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1979, 12 (10): : 979 - 983
  • [2] Temperature Excursions in Cold Chain Management-Assessing the Accuracy of Refrigerator Temperature Probes
    Ferraz, Kayla
    Cato, Melissa
    Fox, Emma
    Rawlins, Matthew
    Misko, Jeanie
    HOSPITAL PHARMACY, 2025, 60 (01) : 66 - 69
  • [3] Precision and accuracy of DFM soil water capacitance probes to measure temperature
    Mjanyelwa, Nokhwezi
    Bello, Zaid A.
    Greaves, Willnerie
    van Rensburg, Leon D.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2016, 125 : 125 - 128
  • [4] Temperature-dependent scaled frequency: Improved accuracy of multisensor capacitance probes
    Fares, A.
    Hamdhani, H.
    Jenkins, D. M.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2007, 71 (03) : 894 - 900
  • [5] Stability, accuracy and application of an FDTD-TDFEM algorithm
    Rylander, T
    Bondeson, A
    Liu, YQ
    IEEE ANTENNAS AND PROPAGATION SOCIETY SYMPOSIUM, VOLS 1-4 2004, DIGEST, 2004, : 1676 - 1679
  • [6] Brain temperature measurement: A study of in vitro accuracy and stability of smart catheter temperature sensors
    Chunyan Li
    Pei-Ming Wu
    Zhizhen Wu
    Chong H. Ahn
    David LeDoux
    Lori A. Shutter
    Jed A. Hartings
    Raj K. Narayan
    Biomedical Microdevices, 2012, 14 : 109 - 118
  • [7] Brain temperature measurement: A study of in vitro accuracy and stability of smart catheter temperature sensors
    Li, Chunyan
    Wu, Pei-Ming
    Wu, Zhizhen
    Ahn, Chong H.
    LeDoux, David
    Shutter, Lori A.
    Hartings, Jed A.
    Narayan, Raj K.
    BIOMEDICAL MICRODEVICES, 2012, 14 (01) : 109 - 118
  • [8] Accuracy Of Skin Probes Vs. Infrared Imaging For Temperature Measurements In Three Different Environments
    Laird, Richard H.
    Elmer, David J.
    Barberio, Matthew D.
    Lee, Khalil A.
    Pascoe, David D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 82 - 82
  • [9] Enhancing Total Temperature Measurement Accuracy: Calibration Procedures and Novel Two-Wire Probes
    de la Rosa, Diego Sanchez
    Paniagua, Guillermo
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2025, 147 (05):
  • [10] ENHANCING TOTAL TEMPERATURE MEASUREMENT ACCURACY: CALIBRATION PROCEDURES AND NOVEL TWO-WIRE PROBES
    de la Rosa, Diego Sanchez
    Paniagua, Guillermo
    PROCEEDINGS OF ASME TURBO EXPO 2024: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2024, VOL 4, 2024,