ENHANCING TOTAL TEMPERATURE MEASUREMENT ACCURACY: CALIBRATION PROCEDURES AND NOVEL TWO-WIRE PROBES

被引:0
|
作者
de la Rosa, Diego Sanchez [1 ]
Paniagua, Guillermo [1 ]
机构
[1] Purdue Univ, W Lafayette, IN 47907 USA
来源
PROCEEDINGS OF ASME TURBO EXPO 2024: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2024, VOL 4 | 2024年
关键词
thermocouples; flow temperature measurement; recovery factor; conduction error; velocity error; calibration methods; infrared thermography; FREQUENCY-RESPONSE; WIRE THERMOCOUPLE;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Total Temperature measurement with thermocouple probes suffers from errors due to heat transfer effects. Two dominant sources of errors are convection and conduction between the thermocouple, the support, and the flow. These effects can be treated in two different categories: the velocity error, created by convection from the internal flow velocity in the probe shield, and the conduction error, involving heat transfer through the wire to the shield and the probe stem due to temperature differences between each component. This paper presents a robust approach to experimentally assess and reduce both errors. An open jet test stand at the Purdue Experimental Turbine Aerothermal Laboratory is used to evaluate the effects of the velocity error at various Mach numbers. Infrared thermography measurements have been conducted to assess temperature gradients on the probe support during this calibration. With this information, it is possible to correct for conduction errors during the calibration and obtain a recovery factor that is solely dependent on upstream velocity. Recovery factor of 0.94 +/-0.05 for Mach 0.2 and 0.98 +/-0.005 for Mach 0.9 are obtained. Progress has been made on a two-wire thermocouple approach to address conduction errors in the testing scenario, where IR thermography is not possible. The readings from two wires with different length-to-diameter ratios are used with a novel linear correction method to correct for the flow total temperature. Advances in the design and manufacturing of the probe are presented, facilitating faster design iterations and implementation, and providing full control over the calibration procedures. This method can correct conduction errors within 0.2 K for Mach 0.6.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Enhancing Total Temperature Measurement Accuracy: Calibration Procedures and Novel Two-Wire Probes
    de la Rosa, Diego Sanchez
    Paniagua, Guillermo
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2025, 147 (05):
  • [2] Increasing Temperature Measurement Accuracy: Method of Two-Wire Connection of a Resistance Thermometer
    O. G. Bondar
    E. O. Brezhneva
    A. I. Kalmykov
    Measurement Techniques, 2022, 65 : 206 - 212
  • [3] Increasing Temperature Measurement Accuracy: Method of Two-Wire Connection of a Resistance Thermometer
    Bondar, O. G.
    Brezhneva, E. O.
    Kalmykov, A., I
    MEASUREMENT TECHNIQUES, 2022, 65 (03) : 206 - 212
  • [4] Intelligent Transducer for Temperature Measurement with Two-Wire or Three-Wire Platinum RTD
    Miczulski, Wieslaw
    Krajewski, Mariusz
    Sienkowski, Sergiusz
    Kawecka, Elzbieta
    Perec, Andrzej
    SENSORS, 2024, 24 (23)
  • [5] DESIGN BENEFITS OF TWO-WIRE TEMPERATURE TRANSMITTERS.
    Burkitt, C.J.
    Electrical Engineer (Melbourne), 1972, 49 (12): : 9 - 10
  • [6] DEVELOPMENT OF A CONDUCTION-FREE TOTAL TEMPERATURE PROBE BASED ON THE TWO-WIRE THERMOCOUPLE CONCEPT
    Alcala, Roberto Nares
    Bhatnagar, Lakshya
    Paniagua, Guillermo
    PROCEEDINGS OF ASME TURBO EXPO 2023: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2023, VOL 4, 2023,
  • [7] A novel lead-wire-resistance compensation technique using two-wire resistance temperature detector
    Maiti, Tapan Kumar
    IEEE SENSORS JOURNAL, 2006, 6 (06) : 1454 - 1458
  • [8] Developing passive MEMS DC/AC current sensor applicable to two-wire appliances with high measurement accuracy
    Wang, Dong F.
    Li, Xiaodong
    Xian, Weikang
    Liu, Huan
    Liu, Xin
    JOURNAL OF APPLIED PHYSICS, 2016, 120 (16)
  • [9] Development of Local Gas Temperature Measurement Technique inside a Combustion Chamber Using Two-Wire Thermocouple
    Kobayashi, Shigemi
    Moriyoshi, Yasuo
    Enomoto, Yoshiteru
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2008, 3 (03): : 486 - 498
  • [10] ON THE ERROR SENSITIVITY OF CALIBRATION PROCEDURES FOR NORMAL HOT-WIRE PROBES
    BURESTI, G
    TALAMELLI, A
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (01) : 17 - 26