Accuracy and stability of temperature probes for intracranial application

被引:11
|
作者
Alessandri, B
Hoelper, BM
Behr, R
Kempski, O
机构
[1] Johannes Gutenberg Univ Mainz, Dept Neurosurg, Inst Neurosurg Pathophysiol, D-55101 Mainz, Germany
[2] Univ Marburg, Acad Hosp, Klinikum Fulda, Dept Neurosurg, Fulda, Germany
关键词
temperature sensor; drift; accuracy; neurotrend; licox; Neurovent-p;
D O I
10.1016/j.jneumeth.2004.04.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Intracranial temperature measurement may play a pivotal role for prognosis and treatment of neurological and neurosurgical patients. For reliable clinical application, accurate temperature readings are therefore necessary. We present an independent in vitro study investigating the accuracy and stability of three temperature probes. Eight Neurovent-P Temp (RN), eight Licox temperature sensors (LT) and eight Neurotrend sensors (NT) were placed into a water bath. The temperature was increased in 3degreesC increments from 30 to 42degreesC before (accuracy test day 0) and after (accuracy test day 5) a long-term stability test run at 37+/-0.2degreesC. The accuracy tests revealed deviations of <0.25, <0.2 and >0.4degreesC for the RN, NT and LT probes, respectively, when compared to the reference measurement by a precision Pt100 temperature measuring instrument. All sensor types showed stable readings over the course of 120 h. The high variability of LT probes was due to a malfunctioning Licox monitor. Excluding these values reduced deviation below 0.21degreesC the standard deviation at each temperature step was below +/-0.08 (RN, NT) and +/-0.12 (LT), laying within the range provided by the manufacturer (RN, NT: +/-0.1; LT: +/-0.2). In general, RN, NT and LT temperature measurement is reliable, but malfunctioning parts may lead to false interpretation of temperature readings. Therefore, validation of temperature probes to a reference temperature prior to clinical use is recommended. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 50 条
  • [31] ACCURACY OF TRANSCRANIAL DOPPLER IN VERTEBROBASILAR INTRACRANIAL STENOSES
    DEBRAY, JM
    LHOSTE, P
    DUBAS, F
    SAUMET, JL
    STROKE, 1995, 26 (04) : 728 - 728
  • [32] Optimality and stability of the ideal free distribution with application to temperature control
    Quijano, Nicanor
    Passino, Kevin M.
    2006 AMERICAN CONTROL CONFERENCE, VOLS 1-12, 2006, 1-12 : 4836 - +
  • [33] A comprehensive evaluation of intracranial SRS treatment accuracy
    Van de Water, T. A.
    Remeijer, P.
    Wittkamper, F.
    Schneider, C.
    Frantzen-Steneker, M.
    Damen, E.
    Panneman, C.
    Geuze, J.
    Kaas, J.
    Van Schie, R.
    Van Mourik, A. M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S460 - S461
  • [34] Modeling of intracranial pressure-temperature dynamics and its application to brain hypothermia treatment
    Lu Gaohua
    Kimura, Hidenori
    2005 44TH IEEE CONFERENCE ON DECISION AND CONTROL & EUROPEAN CONTROL CONFERENCE, VOLS 1-8, 2005, : 1625 - 1630
  • [35] MRI and MRA: Accuracy of assessment of intracranial aneurysms
    Trufanov, GE
    Fokin, VA
    Ratnikov, VA
    Svistov, DV
    RADIOLOGY, 2002, 225 : 206 - 206
  • [36] ACCURACY AND APPLICATION
    SOLIMAN, AH
    PHOTOGRAMMETRIC ENGINEERING, 1971, 37 (08): : 879 - &
  • [37] Dynamic stability of atmospheric entry probes
    Karatekin, O
    Charbonnier, JM
    Wang, F
    Dehant, V
    PLANETARY PROBE ATMOSPHERIC ENTRY AND DESCENT TRAJECTORY ANALYSIS AND SCIENCE, 2004, 544 : 101 - 108
  • [38] Investigation of the stability of commercial neutron probes
    Hoedlmoser, H.
    Butterweck, G.
    Schuler, Ch
    Mayer, S.
    RADIATION PROTECTION DOSIMETRY, 2012, 152 (04) : 450 - 454
  • [39] Evaluation of interpolation accuracy of neural kriging with application to temperature-distribution analysis
    Koike, K
    Matsuda, S
    Gu, B
    MATHEMATICAL GEOLOGY, 2001, 33 (04): : 421 - 448
  • [40] Evaluation of Interpolation Accuracy of Neural Kriging with Application to Temperature-Distribution Analysis
    Katsuaki Koike
    Setsuro Matsuda
    Bin Gu
    Mathematical Geology, 2001, 33 : 421 - 448