The effect of surgical alignment and soft tissue conditions on the kinematics and wear of a fixed bearing total knee replacement

被引:23
|
作者
Johnston, Helena [1 ]
Abdelgaied, Abdellatif [1 ]
Pandit, Hemant [2 ]
Fisher, John [1 ]
Jennings, Louise M. [1 ]
机构
[1] Univ Leeds, Inst Med & Biol Engn, Leeds, W Yorkshire, England
[2] Univ Leeds, Fac Med & Hlth, Leeds Inst Rheumat & Musculoskeletal Med, Leeds, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Total knee replacement; Wear; Surgical alignment; Kinematics; Simulation; Contact mechanics; COMPUTER-ASSISTED NAVIGATION; ANTERIOR CRUCIATE LIGAMENT; TIBIAL COMPONENT; POLYETHYLENE WEAR; FEMORAL ROLLBACK; Q-ANGLE; ARTHROPLASTY; MALALIGNMENT; FAILURE; INSTRUMENTATION;
D O I
10.1016/j.jmbbm.2019.103386
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As life expectancy and activity levels of patients increase so does the demand on total knee replacements (TKRs). Abnormal mechanics and wear of TKRs can lead to implant loosening and revision. Component alignment after surgery varies due to the presurgical alignment, the accuracy of the surgical instrumentation and due to patient factors, such as the soft tissue balance. This study experimentally investigated the effect of variation in component alignment and the soft tissue conditions on the kinematics and wear of a fixed bearing TKR. DePuy Sigma fixed bearing TKRs with moderately cross-linked UHMWPE were used. Different alignment conditions were simulated in the coronal, sagittal and transverse planes in an ISO force-controlled simulation system. Three different soft tissue conditions were simulated using virtual springs to represent a stiff knee, a preserved PCL and a resected PCL. Four different alignment conditions were studied; ideal alignment, 4 degrees tibial and femoral varus joint line, 14 degrees rotational mismatch and 10 degrees posterior tibial slope. The varus joint line alignment resulted in similar kinematics and lower wear rate compared to ideal alignment. The rotational mismatch alignment resulted in significantly higher tibial rotation and abduction-adduction as well as a significantly higher wear rate than ideal alignment. The posterior tibial slope alignment resulted in significantly higher wear than the ideal alignment and dislocated under the lower tension soft tissue conditions. Component alignment and the soft tissue conditions had a significant effect on the kinematics and wear of the TKR investigated in this study. The surgical alignment of the TKR is an important factor in the clinical outcome of the joint as factors such as increased tibial rotation can lead to anterior knee pain and instability and increased wear can lead to aseptic loosening and early failure resulting in revision.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Fixed versus mobile bearing total knee replacement: methodological considerations in systematic reviewing
    Smith, Toby O.
    Donell, Simon T.
    Hing, Caroline B.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (05) : 704 - 706
  • [42] Fixed versus mobile bearing total knee replacement: methodological considerations in systematic reviewing
    Toby O. Smith
    Simon T. Donell
    Caroline B. Hing
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 704 - 706
  • [43] Surgical Technique of Total Knee Arthroplasty without Soft Tissue Balance
    Xu, Hong-tao
    Dong, Jiang-tao
    Wang, Juan
    Gao, Shi-jun
    ORTHOPAEDIC SURGERY, 2016, 8 (04) : 519 - 522
  • [44] The effect of component alignment on clinical outcomes in fixed bearing unicompartmental knee arthroplasty
    Gill, James R.
    Vermuyten, Lieven
    Wastnedge, Elizabeth
    Nicolai, Paul
    KNEE, 2021, 29 : 126 - 133
  • [45] Effect of soft tissue tension on measurements of coronal laxity in mobile-bearing total knee arthroplasty
    Ishii, Y
    Matsuda, Y
    Noguchi, H
    Kiga, H
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2005, 10 (05) : 496 - 500
  • [46] Kinematic behaviour and soft tissue management in guided motion total knee replacement
    Camilla Halewood
    Michael Risebury
    Neil P. Thomas
    Andrew A. Amis
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 3074 - 3082
  • [47] RHEOLOGICAL MEASUREMENT OF SOFT-TISSUE IMBALANCE DURING TOTAL KNEE REPLACEMENT
    ATTFIELD, SF
    WILTON, TJ
    JOURNAL OF ENGINEERING DESIGN, 1995, 6 (02) : 139 - 148
  • [48] Soft tissue management in total knee replacement. Analysis of ligament balancing
    Briard, J.-L.
    Witoolkollachit, P.
    Lin, G.
    ORTHOPADE, 2007, 36 (07): : 635 - 642
  • [49] A New System for Soft-Tissue Balance Measurement in Total Knee Replacement
    Wu, Jian
    Wang, Guangzhi
    Ye, Datian
    Wang, You
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (10) : 3627 - 3632
  • [50] Kinematic behaviour and soft tissue management in guided motion total knee replacement
    Halewood, Camilla
    Risebury, Michael
    Thomas, Neil P.
    Amis, Andrew A.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 3074 - 3082