The effect of surgical alignment and soft tissue conditions on the kinematics and wear of a fixed bearing total knee replacement

被引:23
|
作者
Johnston, Helena [1 ]
Abdelgaied, Abdellatif [1 ]
Pandit, Hemant [2 ]
Fisher, John [1 ]
Jennings, Louise M. [1 ]
机构
[1] Univ Leeds, Inst Med & Biol Engn, Leeds, W Yorkshire, England
[2] Univ Leeds, Fac Med & Hlth, Leeds Inst Rheumat & Musculoskeletal Med, Leeds, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Total knee replacement; Wear; Surgical alignment; Kinematics; Simulation; Contact mechanics; COMPUTER-ASSISTED NAVIGATION; ANTERIOR CRUCIATE LIGAMENT; TIBIAL COMPONENT; POLYETHYLENE WEAR; FEMORAL ROLLBACK; Q-ANGLE; ARTHROPLASTY; MALALIGNMENT; FAILURE; INSTRUMENTATION;
D O I
10.1016/j.jmbbm.2019.103386
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As life expectancy and activity levels of patients increase so does the demand on total knee replacements (TKRs). Abnormal mechanics and wear of TKRs can lead to implant loosening and revision. Component alignment after surgery varies due to the presurgical alignment, the accuracy of the surgical instrumentation and due to patient factors, such as the soft tissue balance. This study experimentally investigated the effect of variation in component alignment and the soft tissue conditions on the kinematics and wear of a fixed bearing TKR. DePuy Sigma fixed bearing TKRs with moderately cross-linked UHMWPE were used. Different alignment conditions were simulated in the coronal, sagittal and transverse planes in an ISO force-controlled simulation system. Three different soft tissue conditions were simulated using virtual springs to represent a stiff knee, a preserved PCL and a resected PCL. Four different alignment conditions were studied; ideal alignment, 4 degrees tibial and femoral varus joint line, 14 degrees rotational mismatch and 10 degrees posterior tibial slope. The varus joint line alignment resulted in similar kinematics and lower wear rate compared to ideal alignment. The rotational mismatch alignment resulted in significantly higher tibial rotation and abduction-adduction as well as a significantly higher wear rate than ideal alignment. The posterior tibial slope alignment resulted in significantly higher wear than the ideal alignment and dislocated under the lower tension soft tissue conditions. Component alignment and the soft tissue conditions had a significant effect on the kinematics and wear of the TKR investigated in this study. The surgical alignment of the TKR is an important factor in the clinical outcome of the joint as factors such as increased tibial rotation can lead to anterior knee pain and instability and increased wear can lead to aseptic loosening and early failure resulting in revision.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty
    Kim, Dongwook
    Seong, Sang Cheol
    Lee, Myung Chul
    Lee, Sahnghoon
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (02) : 337 - 345
  • [32] Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty
    Dongwook Kim
    Sang Cheol Seong
    Myung Chul Lee
    Sahnghoon Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 337 - 345
  • [33] Kinematic alignment is bone and soft tissue preserving compared to mechanical alignment in total knee arthroplasty
    An, Vincent V. G.
    Twiggs, Joshua
    Leie, Murilo
    Fritsch, Brett A.
    KNEE, 2019, 26 (02): : 466 - 476
  • [34] Influence of tibial component posterior slope on in vivo knee kinematics in fixed-bearing total knee arthroplasty
    Catani, F
    Fantozzi, S
    Ensini, A
    Leardini, A
    Moschella, D
    Giannini, S
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (04) : 581 - 587
  • [35] Does total knee joint replacement with the soft tissue balancing surgical technique maintain the natural joint line?
    T. F. Wyss
    A. J. Schuster
    P. Münger
    D. Pfluger
    U. Wehrli
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 480 - 486
  • [36] Contribution of Micro-Motion to Backside Wear in a Fixed Bearing Total Knee Arthroplasty
    Levine, Rayna A. C.
    Lewicki, Kathleen A.
    Currier, John H.
    Mayor, Michael B.
    Van Citters, Douglas W.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2016, 34 (11) : 1933 - 1940
  • [37] Does total knee joint replacement with the soft tissue balancing surgical technique maintain the natural joint line?
    Wyss, T. F.
    Schuster, A. J.
    Muenger, P.
    Pfluger, D.
    Wehrli, U.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (07) : 480 - 486
  • [38] The influence of tibial tray design on the wear of fixed-bearing total knee replacements
    Galvin, A.
    Jennings, L. M.
    McEwen, H. M.
    Fisher, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H8) : 1289 - 1293
  • [39] Influence of design and bearing material on polyethylene wear particle generation in total knee replacement
    Utzschneider, S.
    Paulus, A.
    Datz, J. -C.
    Schroeder, C.
    Sievers, B.
    Wegener, B.
    Jansson, V.
    ACTA BIOMATERIALIA, 2009, 5 (07) : 2495 - 2502
  • [40] A hybrid apparatus for friction and accelerated wear testing of total knee replacement bearing materials
    Chyr, Anthony
    Sanders, Anthony P.
    Raeymaekers, Bart
    WEAR, 2013, 308 (1-2) : 54 - 60