The effect of surgical alignment and soft tissue conditions on the kinematics and wear of a fixed bearing total knee replacement

被引:23
|
作者
Johnston, Helena [1 ]
Abdelgaied, Abdellatif [1 ]
Pandit, Hemant [2 ]
Fisher, John [1 ]
Jennings, Louise M. [1 ]
机构
[1] Univ Leeds, Inst Med & Biol Engn, Leeds, W Yorkshire, England
[2] Univ Leeds, Fac Med & Hlth, Leeds Inst Rheumat & Musculoskeletal Med, Leeds, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Total knee replacement; Wear; Surgical alignment; Kinematics; Simulation; Contact mechanics; COMPUTER-ASSISTED NAVIGATION; ANTERIOR CRUCIATE LIGAMENT; TIBIAL COMPONENT; POLYETHYLENE WEAR; FEMORAL ROLLBACK; Q-ANGLE; ARTHROPLASTY; MALALIGNMENT; FAILURE; INSTRUMENTATION;
D O I
10.1016/j.jmbbm.2019.103386
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As life expectancy and activity levels of patients increase so does the demand on total knee replacements (TKRs). Abnormal mechanics and wear of TKRs can lead to implant loosening and revision. Component alignment after surgery varies due to the presurgical alignment, the accuracy of the surgical instrumentation and due to patient factors, such as the soft tissue balance. This study experimentally investigated the effect of variation in component alignment and the soft tissue conditions on the kinematics and wear of a fixed bearing TKR. DePuy Sigma fixed bearing TKRs with moderately cross-linked UHMWPE were used. Different alignment conditions were simulated in the coronal, sagittal and transverse planes in an ISO force-controlled simulation system. Three different soft tissue conditions were simulated using virtual springs to represent a stiff knee, a preserved PCL and a resected PCL. Four different alignment conditions were studied; ideal alignment, 4 degrees tibial and femoral varus joint line, 14 degrees rotational mismatch and 10 degrees posterior tibial slope. The varus joint line alignment resulted in similar kinematics and lower wear rate compared to ideal alignment. The rotational mismatch alignment resulted in significantly higher tibial rotation and abduction-adduction as well as a significantly higher wear rate than ideal alignment. The posterior tibial slope alignment resulted in significantly higher wear than the ideal alignment and dislocated under the lower tension soft tissue conditions. Component alignment and the soft tissue conditions had a significant effect on the kinematics and wear of the TKR investigated in this study. The surgical alignment of the TKR is an important factor in the clinical outcome of the joint as factors such as increased tibial rotation can lead to anterior knee pain and instability and increased wear can lead to aseptic loosening and early failure resulting in revision.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Measuring the sensitivity of total knee replacement kinematics and laxity to soft tissue imbalances
    Willing, Ryan
    Walker, Peter S.
    JOURNAL OF BIOMECHANICS, 2018, 77 : 62 - 68
  • [2] Fixed and mobile bearing total knee arthroplasty - Influence on wear generation, corresponding wear areas, knee kinematics and particle composition
    Grupp, T. M.
    Kaddick, C.
    Schwiesau, J.
    Maas, A.
    Stulberg, S. D.
    CLINICAL BIOMECHANICS, 2009, 24 (02) : 210 - 217
  • [3] Soft-tissue and alignment correction THE USE OF SMART TRIALS IN TOTAL KNEE REPLACEMENT
    Gustke, K. A.
    BONE & JOINT JOURNAL, 2014, 96B : 78 - 83
  • [4] Computer navigation of soft tissues in total knee replacement: optimizing knee kinematics
    Kamat, Yogeesh D.
    Aurakzai, Kamran M.
    Field, Richard E.
    Adhikari, Ajeya R.
    CURRENT ORTHOPAEDIC PRACTICE, 2010, 21 (06): : 595 - 599
  • [5] Computational wear prediction of a total knee replacement from in vivo kinematics
    Fregly, BJ
    Sawyer, WG
    Harman, MK
    Banks, SA
    JOURNAL OF BIOMECHANICS, 2005, 38 (02) : 305 - 314
  • [6] The wear and kinematics of two medially stabilised total knee replacement systems
    Cowie, Raelene M.
    Cullum, Charles J.
    Collins, Simon N.
    Jennings, Louise M.
    KNEE, 2024, 47 : 160 - 170
  • [7] Effect of conformity and contact stress on wear in fixed-bearing total knee prostheses
    Galvin, Alison L.
    Kang, Lu
    Udofia, Itoro
    Jennings, Louise M.
    McEwen, Hannah M. J.
    Jin, Zhongmin
    Fisher, John
    JOURNAL OF BIOMECHANICS, 2009, 42 (12) : 1898 - 1902
  • [8] The kinematics of fixed- and mobile-bearing total knee arthroplasty
    Most, E
    Li, G
    Schule, S
    Sultan, P
    Park, SE
    Zayontz, S
    Rubash, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) : 197 - 207
  • [9] Fixed bearing knee congruency - influence on contact mechanics, abrasive wear and kinematics
    Grupp, Thomas M.
    Stulberg, Dave
    Kaddick, Christian
    Maas, Allan
    Fritz, Bernhard
    Schwiesau, Jens
    Bloemer, Wilhelm
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (04): : 213 - 223
  • [10] The Effect of Alignment and BMI on Failure of Total Knee Replacement
    Ritter, Merrill A.
    Davis, Kenneth E.
    Meding, John B.
    Pierson, Jeffery L.
    Berend, Michael E.
    Malinzak, Robert A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (17): : 1588 - 1596