A simple dendrimer-aptamer based microfluidic platform for E. coli O157:H7 detection and signal intensification by rolling circle amplification

被引:60
|
作者
Jiang, Yuqian [1 ,2 ]
Zou, Shan [2 ]
Cao, Xudong [1 ]
机构
[1] Univ Ottawa, Dept Chem & Biol Engn, 161 Louis Pasteur, Ottawa, ON K1N 6N5, Canada
[2] Natl Res Council Canada, Measurement Sci & Stand, 100 Sussex Dr, Ottawa, ON K1A 0R6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Signal amplification; Lab-on-a-chip; Microfluidic device; Dendrimer; Aptamer; AFM; LATERAL FLOW BIOSENSOR; A-CHIP DEVICES; UNITED-STATES; FOODBORNE PATHOGENS; SALMONELLA; FOOD; PROTEIN; DNA; DIAGNOSTICS; STRATEGY;
D O I
10.1016/j.snb.2017.05.146
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The majority of foodborne illnesses and deaths are caused by pathogenic bacteria. Therefore there is an increasingly urgent need for rapid, sensitive and cost-effective detection methods in order to avoid or to respond to outbreaks of such diseases in a timely manner. In an attempt to develop a simple and sensitive fluorescence intensity based microfluidic detection platform, PAMAM dendrimer was immobilized onto PDMS microchannel that was further modified with DNA aptamers for detections of E. coli O157:H7 cells. To further improve detection performance, rolling circle amplification (RCA) was employed to enhance the fluorescence signals. In addition, RCA products were characterized by both agarose gel electrophoresis and atomic force microscopy. Our results showed that RCA was able to enhance detection signals by up to 50 times and that the limit of detection of the system was reduced to 10(2) cells/mL with excellent detection specificities. Therefore, it can be concluded that this simple dendrimer-aptamer based microfluidic detection platform with RCA signal enhancement is a promising method for rapid and sensitive detection for foodborne pathogenic bacteria. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:976 / 984
页数:9
相关论文
共 50 条
  • [1] A microfluidic chemiluminescence biosensor based on multiple signal amplification for rapid and sensitive detection of E. coli O157:H7
    Sun, Dongli
    Fan, Tingting
    Liu, Feng
    Wang, Fangxiu
    Gao, Dan
    Lin, Jin-Ming
    BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [2] A microfluidic chemiluminescence biosensor based on multiple signal amplification for rapid and sensitive detection of E. coli O157:H7
    Sun, Dongli
    Fan, Tingting
    Liu, Feng
    Wang, Fangxiu
    Gao, Dan
    Lin, Jin-Ming
    BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [3] Validation of the ANSR® E. coli O157:H7 Method for Detection of E. coli O157:H7
    Viator, Ryan
    Alles, Susan
    Le, Quynh-Nhi
    Hosking, Edan
    Meister, Evan
    Pinkava, Lisa
    Tovar, Eric
    Mozola, Mark
    Rice, Jennifer
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (03) : 705 - 716
  • [4] In situ rolling circle amplification surface modifications to improve E. coli O157:H7 capturing performances for rapid and sensitive microfluidic detection applications
    Li, Shuying
    Jiang, Yuqian
    Yang, Xiuying
    Lin, Min
    Dan, Hanhong
    Zou, Shan
    Cao, Xudong
    ANALYTICA CHIMICA ACTA, 2021, 1150
  • [5] Rolling circle amplification and its application in microfluidic systems for Escherichia coli O157:H7 detections
    Jiang, Yuqian
    Li, Shuying
    Qiu, Zhenyu
    Le, Tao
    Zou, Shan
    Cao, Xudong
    JOURNAL OF FOOD SAFETY, 2019, 39 (05)
  • [6] E. coli O157: H7
    Fernandez, Treor Francis
    VETERINARY WORLD, 2008, 1 (03) : 83 - 87
  • [7] Outbreak:: E. coli O157:H7
    Todd, Betsy
    AMERICAN JOURNAL OF NURSING, 2007, 107 (02) : 29 - 30
  • [8] Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples
    Mishra, Kundan Kumar
    Dhamu, Vikram Narayanan
    Jophy, Chesna
    Muthukumar, Sriram
    Prasad, Shalini
    BIOSENSORS-BASEL, 2024, 14 (06):
  • [9] Separation and detection of E. coli O157:H7 using a SERS-based microfluidic immunosensor
    Sara Asgari
    Rajiv Dhital
    S. Ali Aghvami
    Azlin Mustapha
    Yi Zhang
    Mengshi Lin
    Microchimica Acta, 2022, 189
  • [10] Separation and detection of E. coli O157:H7 using a SERS-based microfluidic immunosensor
    Asgari, Sara
    Dhital, Rajiv
    Aghvami, S. Ali
    Mustapha, Azlin
    Zhang, Yi
    Lin, Mengshi
    MICROCHIMICA ACTA, 2022, 189 (03)