A study on the performance of a newly designed heat pump calorimeter

被引:2
|
作者
Amoabeng, Kofi Owura [1 ]
Choi, Jong Min [2 ]
机构
[1] Hanbat Natl Univ, Grad Sch Mech Engn, Daejeon 34158, South Korea
[2] Hanbat Natl Univ, Dept Mech Engn, Daejeon 34158, South Korea
关键词
Heat pump; Calorimeter; Energy consumption; Entering water temperature; Heat recovery; REFRIGERATION SYSTEM; OPTIMIZATION; COMPRESSOR; EVAPORATOR; EJECTOR;
D O I
10.1016/j.applthermaleng.2017.05.029
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat pump calorimeter is the testing facility to investigate the performance of a heat pump using standard test conditions obtained from domestic or international standard organizations. Conventionally, the calorimeter consumes so much energy in order to control and maintain the entering water temperature test conditions of the water-to-water heat pump unit. To minimize this energy, a newly designed calorimeter for the water-to-water heat pump was proposed in this study. Experiments were conducted in both heating and cooling modes with variation in capacity and COP of heat pump unit. In heating mode, entering water temperature test conditions of 40 degrees C and 5 degrees C were set for the indoor heat exchanger and outdoor heat exchanger of the heat pump unit respectively. In cooling mode, entering water temperature of 25 degrees C and 12 degrees C were set for the outdoor heat exchanger and indoor heat exchanger of the heat pump unit respectively. The analysis of the test results from the experiment showed that the newly designed calorimeter was able to save about 75% or more of the total power consumption comparing with the conventional calorimeter for all heat pump capacity and COP that were investigated. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:216 / 225
页数:10
相关论文
共 50 条
  • [31] Performance study on anOpen cycle absorption heat pump for exhaust heat recycling
    Liu, Jun
    Ye, Bi-Cui
    Chen, Guang-Ming
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2015, 36 (03): : 474 - 477
  • [32] Experimental study on the condensing heat recovery performance of air source heat pump
    Sun, Shuai
    Chen, Hua
    Liu, Xiuli
    [J]. JOURNAL OF ENERGY STORAGE, 2020, 32
  • [33] Heat output performance study of magnesium oxide/water chemical heat pump
    Kato, Y
    Takahashi, F
    Nanmoku, W
    Yoshizawa, Y
    [J]. KAGAKU KOGAKU RONBUNSHU, 1998, 24 (06) : 840 - 844
  • [34] Performance study on heat pump sub-system in parallel of solar assisted heat pump water heater
    Feng, Shiyu
    Gao, Xiufeng
    Hu, Wei
    Li, Yun
    Gu, Zhaolin
    Wang, Huiyu
    Luo, Cong
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2007, 28 (02): : 125 - 129
  • [35] Experimental study of enhancing heating performance of the air-source heat pump by using a novel heat recovery device designed for reusing the energy of the compressor shell
    Huang, Bi
    Jian, Qifei
    Luo, Lizhong
    Zhao, Jing
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 138 : 38 - 44
  • [36] STUDY ON PERFORMANCE OF AIR SOURCE HEAT PUMP WATER HEATER
    Duan, Rui
    [J]. PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 987 - 993
  • [37] STUDY ON PERFORMANCE OF HEAT PUMP WATER HEATERS IN SOUTH AFRICA
    Zhang, M.
    Huan, Z.
    [J]. 2013 PROCEEDINGS OF THE 21ST DOMESTIC USE OF ENERGY CONFERENCE (DUE), 2013, : 119 - 124
  • [38] A Study on the Performance of a Cascade Heat Pump for Generating Hot Water
    Boahen, Samuel
    Choi, Jong Min
    [J]. ENERGIES, 2019, 12 (22)
  • [39] Performance study of an absorption/compression hybrid heat pump cycle
    Wang, Kang
    Zhang, Na
    Han, Wei
    Chen, Qiang
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2015, 36 (11): : 2328 - 2333
  • [40] Study on the influence of refrigerant charge on performance of heat pump units
    Zhao Yuqing
    Dai Yun
    Gao Jianling
    Liu Qingqing
    [J]. 2018 FIRST INTERNATIONAL CONFERENCE ON ENVIRONMENT PREVENTION AND POLLUTION CONTROL TECHNOLOGY (EPPCT 2018), 2018, 199