Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry

被引:68
|
作者
Ternacle, Julien [1 ]
Pibarot, Philippe [1 ]
Herrmann, Howard C. [2 ]
Kodali, Susheel [3 ]
Leipsic, Jonathon [4 ]
Blanke, Philipp [4 ]
Jaber, Wael [5 ]
Mack, Michael J. [6 ]
Clavel, Marie-Annick [1 ]
Salaun, Erwan [1 ]
Guzzetti, Ezequiel [1 ]
Annabi, Mohamed-Salah [1 ]
Bernier, Mathieu [1 ]
Beaudoin, Jonathan [1 ]
Khalique, Omar K. [3 ]
Weissman, Neil J. [7 ]
Douglas, Pamela [8 ]
Bax, Jeroen [9 ]
Dahou, Abdellaziz [10 ]
Xu, Ke [11 ]
Alu, Maria [3 ,10 ]
Rogers, Erin [11 ]
Leon, Martin [3 ,10 ]
Thourani, Vinod H. [12 ]
Abbas, Amr E. [13 ,14 ]
Hahn, Rebecca T. [3 ,10 ]
机构
[1] Univ Laval, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[2] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Columbia Univ, Med Ctr, NewYork Presbyterian Hosp, New York, NY USA
[4] Univ British Columbia, St Pauls Hosp, Vancouver, BC, Canada
[5] Cleveland Clin, Cleveland, OH 44106 USA
[6] Baylor Scott & White Healthcare, Plano, TX USA
[7] Georgetown Univ, MedStar Heath Res Inst, Washington, DC USA
[8] Duke Univ, Duke Clin Res Inst, Med Ctr, Durham, NC USA
[9] Leiden Univ, Dept Cardiol, Med Ctr, Leiden, Netherlands
[10] Cardiovasc Res Fdn, New York, NY USA
[11] Edwards Lifesci, Irvine, CA USA
[12] Marcus Valve Ctr, Piedmont Heart Inst, Dept Cardiovasc Surg, Atlanta, GA USA
[13] Oakland Univ, William Beaumont Sch Med, Auburn Hills, MI USA
[14] Beaumont Hosp Royal Oak, Royal Oak, MI USA
关键词
aortic stenosis; effective orifice area; prosthetic heart valve; prosthesis-patient mismatch; transcatheter aortic valve replacement; transvalvular pressure gradient; INTERMEDIATE-RISK PATIENTS; END-POINT DEFINITIONS; LONG-TERM SURVIVAL; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; TRANSCATHETER; OUTCOMES; IMPACT; IMPLANTATION; STENOSIS;
D O I
10.1016/j.jcin.2021.03.069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). BACKGROUND TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series. METHODS The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi <= 0.85 cm(2)/m2 (<= 0.70 if obese: body mass index >= 30 kg/m(2)) and severe if EOAi <= 0.65 cm(2)/m(2) (<= 0.55 if obese). PPMM was determined by the core lab-measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization. RESULTS The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR. CONCLUSIONS EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR. (C) 2021 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:1466 / 1477
页数:12
相关论文
共 50 条
  • [1] Incidence and Impact of Prosthesis-Patient Mismatch after Aortic Valve Replacement in the PARTNER 2 Trial and Registry
    Ternacle, Julien
    Pibarot, Philippe
    Herrmann, Howard
    Kodali, Susheel
    Leipsic, Jonathon
    Blanke, Philipp
    Jaber, Wael
    Mack, Michael
    Clavel, Marie-Annick
    Salaun, Erwan
    Bernier, Mathieu
    Beaudoin, Jonathan
    Khalique, Omar
    Weissman, Neil
    Douglas, Pamela
    Bax, Jeroen
    Dahou, Abdellaziz
    Xu, Ke
    Alu, Maria
    Rogers, Erin
    Leon, Martin
    Thourani, Vinod
    Abbas, Amr
    Hahn, Rebecca
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B202 - B203
  • [2] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [3] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [4] The relevance of prosthesis-patient mismatch after aortic valve replacement
    Pibarot, Philippe
    Dumesnil, Jean G.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 764 - 765
  • [5] Impact of Flow on the Incidence and Prognosis of Prosthesis-Patient Mismatch Following Aortic Valve Replacement in the PARTNER 2 Study and Registry
    Abbas, Amr
    Pibarot, Philippe
    Hahn, Rebecca
    Ternacle, Julien
    Bax, Jeroen
    Xu, Ke
    Alu, Maria
    Rogers, Erin
    Mack, Michael
    Leon, Martin
    Thourani, Vinod
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B43 - B44
  • [7] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Sa, Michel Pompeu
    Jacquemyn, Xander
    Van den Eynde, Jef
    Tasoudis, Panagiotis
    Dokollari, Aleksander
    Torregrossa, Gianluca
    Sicouri, Serge
    Clavel, Marie-Annick
    Pibarot, Philippe
    Ramlawi, Basel
    JACC-CARDIOVASCULAR IMAGING, 2022, 16 (03) : 298 - 310
  • [8] Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Dayan, Victor
    Vignolo, Gustavo
    Soca, Gerardo
    Paganini, Juan Jose
    Brusich, Daniel
    Pibarot, Philippe
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) : 924 - 933
  • [9] Prosthesis-patient mismatch affects survival after aortic valve replacement
    Rao, V
    Jamieson, WRE
    Ivanov, J
    Armstrong, S
    David, TE
    CIRCULATION, 2000, 102 (19) : 5 - 9
  • [10] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Levesque, Thomas
    Eltchaninoff, Helene
    Chabannes, Romain
    Barbe, Thomas
    Dosseh, Olivier
    Tron, Christophe
    Bettinger, Nicolas
    Bouhzam, Najime
    Hemery, Thibaut
    le Pessec, Guillaume
    Fauvel, Charles
    Cribier, Alain
    Pibarot, Philippe
    Durand, Eric
    CANADIAN JOURNAL OF CARDIOLOGY, 2024, 40 (01) : 113 - 122