Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes

被引:1
|
作者
Khajeh, Masoud [1 ]
Safigholi, Habib [2 ]
机构
[1] Islamic Azad Univ, Marvdasht Branch, Dept Mech, Marvdasht, Iran
[2] Islamic Azad Univ, Shiraz Branch, Coll Engn, Dept Elect Engn, Shiraz, Iran
关键词
Electronic brachytherapy; Target; Monte Carlo; Computational fluid dynamic; TG-43U1; DOSIMETRY; PARAMETERS;
D O I
10.1016/j.jare.2015.04.006
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A miniature X-ray source has been optimized for electronic brachytherapy. The cooling fluid for this device is water. Unlike the radionuclide brachytherapy sources, this source is able to operate at variable voltages and currents to match the dose with the tumor depth. First, Monte Carlo (MC) optimization was performed on the tungsten target-buffer thickness layers versus energy such that the minimum X-ray attenuation occurred. Second optimization was done on the selection of the anode shape based on the Monte Carlo in water TG-43U1 anisotropy function. This optimization was carried out to get the dose anisotropy functions closer to unity at any angle from 0 degrees to 170 degrees. Three anode shapes including cylindrical, spherical, and conical were considered. Moreover, by Computational Fluid Dynamic (CFD) code the optimal target-buffer shape and different nozzle shapes for electronic brachytherapy were evaluated. The characterization criteria of the CFD were the minimum temperature on the anode shape, cooling water, and pressure loss from inlet to outlet. The optimal anode was conical in shape with a conical nozzle. Finally, the TG-43U1 parameters of the optimal source were compared with the literature. (C) 2015 Production and hosting by Elsevier B.V. on behalf of Cairo University.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 50 条
  • [41] Quantitative X-Ray Microanalysis of Heterogeneous Materials Using Monte Carlo Simulations
    Raynald Gauvin
    Microchimica Acta, 2006, 155 : 75 - 81
  • [42] Towards Monte Carlo simulation of X-ray phase contrast using GATE
    Langer, Max
    Cen, Zhenjie
    Rit, Simon
    Letang, Jean M.
    OPTICS EXPRESS, 2020, 28 (10) : 14522 - 14535
  • [43] Monte Carlo Simulation of X-Ray Imaging Using a Graphics Processing Unit
    Badal, Andreu
    Badano, Aldo
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4081 - 4084
  • [44] Detection of radium in water by x-ray fluorescence using Monte Carlo simulations
    Burille, F.
    Correa, J. J. M.
    Zambianchi, P.
    Zambianchi, J. K.
    Antoniassi, M.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [45] Monte Carlo methods for the in vivo analysis of cisplatin using X-ray fluorescence
    Hugtenburg, RP
    Turner, JR
    Mannering, DM
    Robinson, BA
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 673 - 676
  • [46] Modelling diffractive X-ray scattering using the EGS Monte Carlo code
    O'Dwyer, J. N.
    Tickner, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 127 - 129
  • [47] Intravaginal electronic brachytherapy using a 50kV X-ray source
    Schneider, F.
    Fuchs, H.
    Lorenz, F.
    Steil, V.
    Ziglio, F.
    Lohr, F.
    Wenz, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S584 - S584
  • [48] Monte Carlo simulation of a miniature, radiosurgery x-ray tube using the ITS 3.0 coupled electron-photon transport code
    Department of Nuclear Engineering, Whitaker Coll. Hlth. Sci. Technol., Massachusetts Inst. of Technology, Cambridge, MA 02139, United States
    不详
    MED. PHYS., 9 (1551-1558):
  • [49] Monte Carlo simulation of a miniature, radiosurgery x-ray tube using the ITS 3.0 coupled electron-photon transport code
    Yanch, JC
    Harte, KJ
    MEDICAL PHYSICS, 1996, 23 (09) : 1551 - 1558
  • [50] Monte Carlo optimization multi-pass Bremsstrahlung target for pulsed X-ray source
    Plokhoi, V
    Modestov, D
    Kandiev, Y
    PPC-2003: 14TH IEEE INTERNATIONAL PULSED POWER CONFERENCE, VOLS 1 AND 2, DIGEST OF TECHNICAL PAPERS, 2003, : 779 - 782