Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes

被引:1
|
作者
Khajeh, Masoud [1 ]
Safigholi, Habib [2 ]
机构
[1] Islamic Azad Univ, Marvdasht Branch, Dept Mech, Marvdasht, Iran
[2] Islamic Azad Univ, Shiraz Branch, Coll Engn, Dept Elect Engn, Shiraz, Iran
关键词
Electronic brachytherapy; Target; Monte Carlo; Computational fluid dynamic; TG-43U1; DOSIMETRY; PARAMETERS;
D O I
10.1016/j.jare.2015.04.006
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A miniature X-ray source has been optimized for electronic brachytherapy. The cooling fluid for this device is water. Unlike the radionuclide brachytherapy sources, this source is able to operate at variable voltages and currents to match the dose with the tumor depth. First, Monte Carlo (MC) optimization was performed on the tungsten target-buffer thickness layers versus energy such that the minimum X-ray attenuation occurred. Second optimization was done on the selection of the anode shape based on the Monte Carlo in water TG-43U1 anisotropy function. This optimization was carried out to get the dose anisotropy functions closer to unity at any angle from 0 degrees to 170 degrees. Three anode shapes including cylindrical, spherical, and conical were considered. Moreover, by Computational Fluid Dynamic (CFD) code the optimal target-buffer shape and different nozzle shapes for electronic brachytherapy were evaluated. The characterization criteria of the CFD were the minimum temperature on the anode shape, cooling water, and pressure loss from inlet to outlet. The optimal anode was conical in shape with a conical nozzle. Finally, the TG-43U1 parameters of the optimal source were compared with the literature. (C) 2015 Production and hosting by Elsevier B.V. on behalf of Cairo University.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 50 条
  • [21] Dosimetry and Monte Carlo modelling of the Papillon plus contact X-ray brachytherapy device
    Colson, Dries
    Yalvac, Burak
    Weterings, Jan
    Verrijssen, An-Sofie
    van Haaren, Paul
    Bellezzo, Murillo
    Berbee, Maaike
    Van Limbergen, Evert J.
    Croce, Olivier
    Verhaegen, Frank
    Reniers, Brigitte
    BRACHYTHERAPY, 2024, 23 (05) : 535 - 548
  • [22] X-RAY COLLIMATOR DESIGN USING MONTE CARLO SIMULATIONS
    Han, Eun Young
    Clarkson, Richard
    Sharma, Sunil
    Corry, Peter M.
    Moros, Eduardo G.
    Ratanatharathorn, Vaneerat
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2013, 25 (06):
  • [23] Diagnostic x-ray dosimetry using Monte Carlo simulation
    Ioppolo, JL
    Price, RI
    Tuchyna, T
    Buckley, CE
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10): : 1707 - 1720
  • [24] Optimization of x-ray spectra in digital mammography through Monte Carlo simulations
    Cunha, D. M.
    Tomal, A.
    Poletti, M. E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07): : 1919 - 1935
  • [25] Optimization of X-Ray Diffraction Imaging of Medical Specimens by Monte Carlo Methods
    Japzon, M.
    Kapadia, A.
    Nacouzi, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E142 - E142
  • [26] Feasibility of 4D HDR brachytherapy source tracking using x-ray tomosynthesis: Monte Carlo investigation
    Vasyltsiv, Roman
    Qian, Xin
    Xu, Zhigang
    Ryu, Samuel
    Zhao, Wei
    Howansky, Adrian
    MEDICAL PHYSICS, 2023, 50 (08) : 4695 - 4709
  • [27] X-ray Microanalysis of Porous Materials Using Monte Carlo Simulations
    Poirier, Dominique
    Gauvin, Raynald
    SCANNING, 2011, 33 (03) : 126 - 134
  • [28] Monte Carlo study on focus properties of portable ultrabright microfocus x-ray sources
    Wang Kai-Ge
    Wang Lei
    Liu Wen-Qing
    Niu Han-Ben
    CHINESE PHYSICS LETTERS, 2006, 23 (09) : 2368 - 2371
  • [29] Compact x-ray sources for mammographic applications: Monte Carlo simulations of image quality
    Oliva, P.
    Golosio, B.
    Stumbo, S.
    Bravin, A.
    Tomassini, P.
    MEDICAL PHYSICS, 2009, 36 (11) : 5149 - 5161
  • [30] A Monte Carlo simulation model of mammographic imaging with x-ray sources of finite dimensions
    Spyrou, G
    Tzanakos, G
    Nikiforides, G
    Panayiotakis, G