Continuous Glucose Monitoring and Glycemic Control in Patients With Type 2 Diabetes Mellitus and CKD

被引:8
|
作者
Presswala, Lubaina [1 ,2 ]
Hong, Susana [1 ,2 ]
Harris, Yael [1 ,2 ]
Romao, Isabela [1 ,2 ]
Zhang, Meng [1 ,2 ]
Jhaveri, Kenar D. [1 ,2 ]
Sakhiya, Vipul [1 ,2 ]
Fishbane, Steven [1 ,2 ]
机构
[1] Donald & Barbara Zucker Sch Med Hofstra Northwell, Div Nephrol, Dept Med, Great Neck, NY USA
[2] Donald & Barbara Zucker Sch Med Hofstra Northwell, Div Endocrinol, Dept Med, Great Neck, NY USA
关键词
chronic kidney disease; continuous glucose monitoring; diagnostic test study; glycated hemoglobin; HbA[!sub]1c[!/sub; Type; 2; diabetes;
D O I
10.1016/j.xkme.2019.07.006
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Rationale & Objective: The accuracy of glycated hemoglobin (HbA(1c)) level for assessment of glycemic control in patients with chronic kidney disease (CKD) is uncertain. This study assessed the accuracy of HbA(1c) level using continuous glucose monitoring. Study Design: Diagnostic test study of HbA(1c) and serum fructosamine. The continuous glucose monitor was worn for 14 days. Glucose was measured every 15 minutes (up to 1,344 measurements). Average glucose concentration was calculated for each patient from the patient's continuous glucose monitor measurements. Linear regression was applied to estimate the relationship between average glucose concentration and HbA(1c) and serum fructosamine levels. The influence of patient characteristics on the relationship between HbA(1c) and average glucose concentrations was examined in a multivariate regression model. Setting & Participants: Patients with type 2 diabetes and CKD (estimated glomerular filtration rate, 7-45 mL/min, not receiving dialysis) seen in an academic nephrology clinic. Tests Analyzed: The accuracy of HbA(1c) level for assessment of chronic glycemia. A secondary objective was to study serum fructosamine levels. Outcomes: The degree of correlation between continuous glucose monitoring-derived average glucose concentration and HbA(1c) level; serum fructosamine level was studied as a secondary outcome. Results: 80 patients wore the continuous glucose monitor for a mean of 12.7 +/- 2.9 days. Average glucose concentration of all patients was 151.5 +/- 55.7 mg/dL. Mean HbA(1c) level was 7.2%+/- 1.5%. HbA(1c) level was highly correlated with average glucose concentration, described by the equation: average glucose concentration = 30.48 x HbA(1c) - 68.48; r= 0.82; P < 0.001. Serum fructosamine level was also significantly correlated with average glucose concentration; r= 0.55; P < 0.001. The strong correlation between average glucose concentration and HbA(1c) level was not affected by the severity of CKD, whereas the performance of serum fructosamine level, in contrast, degraded among patients with more severe CKD. Limitations: Relatively small sample size. Conclusions: HbA(1c) is an accurate measure of glycemic status among patients with CKD and type 2 diabetes. This relationship appears to hold true among patients with more severe CKD.
引用
收藏
页码:281 / 287
页数:7
相关论文
共 50 条
  • [31] IMPACT OF EARLY INITIATION OF CONTINUOUS GLUCOSE MONITORING ON GLYCEMIC CONTROL IN PEDIATRIC PATIENTS WITH TYPE 1 DIABETES
    Wadwa, R. P.
    Hanes, S.
    Clay, M.
    Weber, I.
    Forlenza, G.
    Buckingham, B.
    Nally, L.
    Hood, K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A98 - A99
  • [32] Glycemic control in patients with type 2 diabetes mellitus in Spain
    Perez, A.
    Mediavilla, J. J.
    Minambres, I.
    Gonzalez-Segura, D.
    REVISTA CLINICA ESPANOLA, 2014, 214 (08): : 429 - 436
  • [33] Evaluating Glycemic Control During Basalin or Lantus Administration in Adults With Controlled Type 2 Diabetes Mellitus Using Continuous Glucose Monitoring
    Wang, Huiying
    Zhou, Yunting
    Zhai, Xiaofang
    Ding, Bo
    Jing, Ting
    Su, Xiaofei
    Li, Huiqin
    Ma, Jianhua
    FRONTIERS IN ENDOCRINOLOGY, 2021, 12
  • [34] Glycemic excursions throughout the day revealed by continuous glucose monitoring in subjects with normal glucose tolerance and type 2 diabetes mellitus
    Yu, Ming
    Zhou, Jian
    Jia, Weiping
    Li, Ming
    Lu, Wei
    Xiang, Kunsan
    DIABETES, 2007, 56 : A111 - A111
  • [35] Continuous Glucose Monitoring in Patients With Type 2 Diabetes
    Beck, R. W.
    Riddlesworth, T. D.
    Ruedy, K.
    Ahmann, A.
    Haller, S.
    Kruger, D.
    McGill, J. B.
    Polonsky, W.
    Price, D.
    Aronoff, S.
    Aronson, R.
    Toschi, E.
    Kollman, C.
    Bergenstal, R.
    ANNALS OF INTERNAL MEDICINE, 2017, 167 (06) : I20 - I20
  • [36] Continuous glucose monitoring for the routine care of type 2 diabetes mellitus
    Ajjan, Ramzi
    Battelino, Tadej
    Cos, Xavier
    Del Prato, Stefano
    Philips, Jean-Christophe
    Meyer, Laurent
    Seufert, Jochen
    Seidu, Samuel
    NATURE REVIEWS ENDOCRINOLOGY, 2024, 20 (07) : 426 - 440
  • [37] Continuous glucose monitoring in type 1 diabetes mellitus
    Pavlicek, Vojtech
    DIABETOLOGE, 2019, 15 (08): : 744 - 746
  • [38] Continuous glucose monitoring in type 1 diabetes mellitus
    Tamborlane, William V.
    Beck, Roy W.
    LANCET, 2009, 373 (9677): : 1744 - 1746
  • [39] Continuous Glucose Monitoring and Glycemic Control in People With Type 2 Diabetes: Real-World Study
    Maldonado Reyes, Alondra Nicole
    Lugo de la Cruz, Arely Joseline
    Ramirez Frias, Cecilia Nohemi
    Mirafuentes Rios, Martha Evelyn
    Aguilar Barrera, Eliud Salvador
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2022, 128 : S50 - S50
  • [40] Comparison of Glycemic Excursion Using Flash Continuous Glucose Monitoring in Patients with Type 2 Diabetes Mellitus Before and After Treatment with Voglibose
    Kasthuri, Selvam
    Poongothai, Subramani
    Anjana, Ranjit Mohan
    Selvakumar, Jayvel
    Muthukumar, Subramaniam
    Kayalvizhi, Sengottuevel
    Tariq, Syed
    Honey, Evangelin
    Gupta, Prasanna Kumar
    Venkatesan, Ulagamathesan
    Mohan, Viswanathan
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (03) : 213 - 220