Continuous Glucose Monitoring and Glycemic Control in Patients With Type 2 Diabetes Mellitus and CKD

被引:8
|
作者
Presswala, Lubaina [1 ,2 ]
Hong, Susana [1 ,2 ]
Harris, Yael [1 ,2 ]
Romao, Isabela [1 ,2 ]
Zhang, Meng [1 ,2 ]
Jhaveri, Kenar D. [1 ,2 ]
Sakhiya, Vipul [1 ,2 ]
Fishbane, Steven [1 ,2 ]
机构
[1] Donald & Barbara Zucker Sch Med Hofstra Northwell, Div Nephrol, Dept Med, Great Neck, NY USA
[2] Donald & Barbara Zucker Sch Med Hofstra Northwell, Div Endocrinol, Dept Med, Great Neck, NY USA
关键词
chronic kidney disease; continuous glucose monitoring; diagnostic test study; glycated hemoglobin; HbA[!sub]1c[!/sub; Type; 2; diabetes;
D O I
10.1016/j.xkme.2019.07.006
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Rationale & Objective: The accuracy of glycated hemoglobin (HbA(1c)) level for assessment of glycemic control in patients with chronic kidney disease (CKD) is uncertain. This study assessed the accuracy of HbA(1c) level using continuous glucose monitoring. Study Design: Diagnostic test study of HbA(1c) and serum fructosamine. The continuous glucose monitor was worn for 14 days. Glucose was measured every 15 minutes (up to 1,344 measurements). Average glucose concentration was calculated for each patient from the patient's continuous glucose monitor measurements. Linear regression was applied to estimate the relationship between average glucose concentration and HbA(1c) and serum fructosamine levels. The influence of patient characteristics on the relationship between HbA(1c) and average glucose concentrations was examined in a multivariate regression model. Setting & Participants: Patients with type 2 diabetes and CKD (estimated glomerular filtration rate, 7-45 mL/min, not receiving dialysis) seen in an academic nephrology clinic. Tests Analyzed: The accuracy of HbA(1c) level for assessment of chronic glycemia. A secondary objective was to study serum fructosamine levels. Outcomes: The degree of correlation between continuous glucose monitoring-derived average glucose concentration and HbA(1c) level; serum fructosamine level was studied as a secondary outcome. Results: 80 patients wore the continuous glucose monitor for a mean of 12.7 +/- 2.9 days. Average glucose concentration of all patients was 151.5 +/- 55.7 mg/dL. Mean HbA(1c) level was 7.2%+/- 1.5%. HbA(1c) level was highly correlated with average glucose concentration, described by the equation: average glucose concentration = 30.48 x HbA(1c) - 68.48; r= 0.82; P < 0.001. Serum fructosamine level was also significantly correlated with average glucose concentration; r= 0.55; P < 0.001. The strong correlation between average glucose concentration and HbA(1c) level was not affected by the severity of CKD, whereas the performance of serum fructosamine level, in contrast, degraded among patients with more severe CKD. Limitations: Relatively small sample size. Conclusions: HbA(1c) is an accurate measure of glycemic status among patients with CKD and type 2 diabetes. This relationship appears to hold true among patients with more severe CKD.
引用
收藏
页码:281 / 287
页数:7
相关论文
共 50 条
  • [21] Glycemic control with the basal/bolus insulin delivery system hPATCH™ measured by continuous glucose monitoring system (CGMS) in patients with type 2 diabetes mellitus
    Strange, Poul
    Kapitza, Christoph
    Schleusener, Debra
    Fein, Seymour
    DIABETES, 2007, 56 : A121 - A121
  • [22] Addition of Canagliflozin to Insulin Improves Glycemic Control and Reduces Insulin Dose in Patients with Type 2 Diabetes Mellitus: A Study Based on Continuous Glucose Monitoring
    Torimoto, Keiichi
    Okada, Yosuke
    Sato, Yasunori
    Tanaka, Yoshiya
    DIABETES, 2019, 68
  • [23] Glycemic Variability and Metabolic Control in Patients with Diabetes Mellitus: Significance of Indicators Obtained with Continuous Glucose Monitoring (CGM)
    Sartore, Giovanni
    Chilelli, Nino Cristiano
    Burlina, Silvia
    Di Stefano, Paola
    Fedele, Domenico
    Lapolla, Annunziata
    DIABETES, 2011, 60 : A583 - A583
  • [24] Association between glycemic control assessed by continuous glucose monitoring and stroke in patients with atrial fibrillation and diabetes mellitus
    Guo, Jinhui
    Wang, Juan
    Zhao, Zepeng
    Yu, Lifang
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (08) : 9157 - 9164
  • [25] Continuous glucose monitoring during gestation in patients with pregestational type 2 diabetes mellitus
    Morales, Maria del Mar
    Acho, Edwin
    Castrillon, Carolina
    Marcelo, Humberto
    Vera, Edy
    Lopez, Eddy
    Zhang, Cristian
    Leey, Julio
    REVISTA PERUANA DE GINECOLOGIA Y OBSTETRICIA, 2022, 68 (03): : 8 - 8
  • [26] Frequency of blood glucose monitoring in relation to glycemic control in patients with type 2 diabetes
    Harris, MI
    DIABETES CARE, 2001, 24 (06) : 979 - 982
  • [27] Frequency of blood glucose monitoring in relation to glycemic control in patients with type 2 diabetes
    Blonde, L
    Ginsberg, BH
    Horn, S
    Hirsch, IB
    James, B
    Mulcahy, K
    Nettles, A
    Smout, R
    Wright, H
    DIABETES CARE, 2002, 25 (01) : 245 - 246
  • [28] The effects of professional continuous glucose monitoring as an adjuvant educational tool for improving glycemic control in patients with type 2 diabetes
    Rivera-Avila, Dulce Adelaida
    Esquivel-Lu, Alejandro Ivan
    Salazar-Lozano, Carlos Rafael
    Jones, Kyla
    Doubova, Svetlana V.
    BMC ENDOCRINE DISORDERS, 2021, 21 (01)
  • [29] Can the Use of Continuous Glucose Monitoring Improve Glycemic Control in Patients with Type 1 and 2 Diabetes Receiving Dialysis?
    Bomholt, Tobias
    Kofod, Dea
    Norgaard, Kirsten
    Rossing, Peter
    Feldt-Rasmussen, Bo
    Hornum, Mads
    NEPHRON, 2023, 147 (02) : 91 - 96
  • [30] The effects of professional continuous glucose monitoring as an adjuvant educational tool for improving glycemic control in patients with type 2 diabetes
    Dulce Adelaida Rivera-Ávila
    Alejandro Iván Esquivel-Lu
    Carlos Rafael Salazar-Lozano
    Kyla Jones
    Svetlana V. Doubova
    BMC Endocrine Disorders, 21