Continuous Glucose Monitoring and Glycemic Control in Patients With Type 2 Diabetes Mellitus and CKD

被引:8
|
作者
Presswala, Lubaina [1 ,2 ]
Hong, Susana [1 ,2 ]
Harris, Yael [1 ,2 ]
Romao, Isabela [1 ,2 ]
Zhang, Meng [1 ,2 ]
Jhaveri, Kenar D. [1 ,2 ]
Sakhiya, Vipul [1 ,2 ]
Fishbane, Steven [1 ,2 ]
机构
[1] Donald & Barbara Zucker Sch Med Hofstra Northwell, Div Nephrol, Dept Med, Great Neck, NY USA
[2] Donald & Barbara Zucker Sch Med Hofstra Northwell, Div Endocrinol, Dept Med, Great Neck, NY USA
关键词
chronic kidney disease; continuous glucose monitoring; diagnostic test study; glycated hemoglobin; HbA[!sub]1c[!/sub; Type; 2; diabetes;
D O I
10.1016/j.xkme.2019.07.006
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Rationale & Objective: The accuracy of glycated hemoglobin (HbA(1c)) level for assessment of glycemic control in patients with chronic kidney disease (CKD) is uncertain. This study assessed the accuracy of HbA(1c) level using continuous glucose monitoring. Study Design: Diagnostic test study of HbA(1c) and serum fructosamine. The continuous glucose monitor was worn for 14 days. Glucose was measured every 15 minutes (up to 1,344 measurements). Average glucose concentration was calculated for each patient from the patient's continuous glucose monitor measurements. Linear regression was applied to estimate the relationship between average glucose concentration and HbA(1c) and serum fructosamine levels. The influence of patient characteristics on the relationship between HbA(1c) and average glucose concentrations was examined in a multivariate regression model. Setting & Participants: Patients with type 2 diabetes and CKD (estimated glomerular filtration rate, 7-45 mL/min, not receiving dialysis) seen in an academic nephrology clinic. Tests Analyzed: The accuracy of HbA(1c) level for assessment of chronic glycemia. A secondary objective was to study serum fructosamine levels. Outcomes: The degree of correlation between continuous glucose monitoring-derived average glucose concentration and HbA(1c) level; serum fructosamine level was studied as a secondary outcome. Results: 80 patients wore the continuous glucose monitor for a mean of 12.7 +/- 2.9 days. Average glucose concentration of all patients was 151.5 +/- 55.7 mg/dL. Mean HbA(1c) level was 7.2%+/- 1.5%. HbA(1c) level was highly correlated with average glucose concentration, described by the equation: average glucose concentration = 30.48 x HbA(1c) - 68.48; r= 0.82; P < 0.001. Serum fructosamine level was also significantly correlated with average glucose concentration; r= 0.55; P < 0.001. The strong correlation between average glucose concentration and HbA(1c) level was not affected by the severity of CKD, whereas the performance of serum fructosamine level, in contrast, degraded among patients with more severe CKD. Limitations: Relatively small sample size. Conclusions: HbA(1c) is an accurate measure of glycemic status among patients with CKD and type 2 diabetes. This relationship appears to hold true among patients with more severe CKD.
引用
收藏
页码:281 / 287
页数:7
相关论文
共 50 条
  • [1] Improved glycemic control with teneligliptin in patients with type 2 diabetes mellitus on hemodialysis: Evaluation by continuous glucose monitoring
    Wada, Noritsugu
    Mori, Katsuhito
    Nakagawa, Chie
    Sawa, Jun
    Kumeda, Yasuro
    Shoji, Tetsuo
    Emoto, Masanori
    Inaba, Masaaki
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2015, 29 (08) : 1310 - 1313
  • [2] The glycemic patterns and excursions as in patients with type 2 diabetes mellitus by continuous glucose monitoring system (CGMS)
    Ming, Y
    Zhou, YC
    Jian, Z
    Xiang, KS
    DIABETES, 2003, 52 : A101 - A101
  • [3] Navigating the Seas of Glycemic Control: The Role of Continuous Glucose Monitoring in Type 1 Diabetes Mellitus
    Moon, Jun Sung
    DIABETES & METABOLISM JOURNAL, 2023, 47 (03) : 345 - 346
  • [4] Glycemic Control Assessed by Continuous Glucose Monitoring among Dialysis Patients With and Without Diabetes Mellitus
    Mayeda, Laura
    Zelnick, Leila
    Trikudanathan, Subbulaxmi
    Hirsch, Irl B.
    Watnick, Suzanne
    De Boer, Ian
    DIABETES, 2023, 72
  • [5] Tirzepatide and Glycemic Control Metrics Using Continuous Glucose Monitoring in Older Patients with Type 2 Diabetes Mellitus: An Observational Pilot Study
    Omura, Takuya
    Inami, Akemi
    Sugimoto, Taiki
    Kawashima, Shuji
    Sakurai, Takashi
    Tokuda, Haruhiko
    GERIATRICS, 2024, 9 (02)
  • [6] The effects of aging and frailty on inpatient glycemic control by continuous glucose monitoring in patients with type 2 diabetes
    Idrees, T.
    Zabala, Z. E.
    Moreno, E. M.
    Gerges, A.
    Urrutia, M. A.
    Ruiz, J. G.
    Vaughan, C.
    Vellanki, P.
    Pasquel, F. J.
    Peng, L.
    Umpierrez, G. E.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 198
  • [7] Continuous Glucose Monitoring and Glycemic Control in Patients With Type 2 Diabetes Treated With Basal Insulin Reply
    Martens, Thomas W.
    Beck, Roy W.
    Bergenstal, Richard M.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 326 (13): : 1330 - +
  • [8] Self Monitoring Effect on Glycemic Control of Type 2 Diabetes Mellitus Patients
    Hariyono, Hariyono
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (01): : 459 - 462
  • [9] EFFICACY OF A TELEMEDICINE SYSTEM ON GLYCEMIC CONTROL IN ELDERLY PATIENTS WITH TYPE 2 DIABETES MELLITUS AND FLASH GLUCOSE MONITORING
    Delli Poggi, C.
    Caiulo, C.
    Scoccimarro, D.
    Vitale, V.
    Marinelli, C.
    Del Vescovo, G. G.
    Mannucci, E.
    Dicembrini, I.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A251 - A251
  • [10] Association between self-monitoring of blood glucose and glycemic control in patients with type 2 diabetes mellitus
    Wen, L
    Parchman, ML
    Linn, WD
    Lee, S
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2004, 61 (22) : 2401 - 2405