Accelerated iterative beam angle selection in IMRT

被引:18
|
作者
Bangert, Mark [1 ]
Unkelbach, Jan [2 ,3 ]
机构
[1] German Canc Res Ctr, Dept Med Phys Radiat Oncol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
intensity-modulated radiation therapy; treatment planning; beam angle selection; MODULATED RADIATION-THERAPY; ORIENTATION OPTIMIZATION; RADIOTHERAPY; GENERATION; PERFORMANCE; NUMBER; TUMORS; PLANS;
D O I
10.1118/1.4940350
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Iterative methods for beam angle selection (BAS) for intensity-modulated radiation therapy (IMRT) planning sequentially construct a beneficial ensemble of beam directions. In a naive implementation, the nth beam is selected by adding beam orientations one-by-one from a discrete set of candidates to an existing ensemble of (n-1) beams. The best beam orientation is identified in a time consuming process by solving the fluence map optimization (FMO) problem for every candidate beam and selecting the beam that yields the largest improvement to the objective function value. This paper evaluates two alternative methods to accelerate iterative BAS based on surrogates for the FMO objective function value. Methods: We suggest to select candidate beams not based on the FMO objective function value after convergence but (1) based on the objective function value after five FMO iterations of a gradient based algorithm and (2) based on a projected gradient of the FMO problem in the first iteration. The performance of the objective function surrogates is evaluated based on the resulting objective function values and dose statistics in a treatment planning study comprising three intracranial, three pancreas, and three prostate cases. Furthermore, iterative BAS is evaluated for an application in which a small number of noncoplanar beams complement a set of coplanar beam orientations. This scenario is of practical interest as noncoplanar setups may require additional attention of the treatment personnel for every couch rotation. Results: Iterative BAS relying on objective function surrogates yields similar results compared to naive BAS with regard to the objective function values and dose statistics. At the same time, early stopping of the FMO and using the projected gradient during the first iteration enable reductions in computation time by approximately one to two orders of magnitude. With regard to the clinical delivery of noncoplanar IMRT treatments, we could show that optimized beam ensembles using only a few noncoplanar beam orientations often approach the plan quality of fully noncoplanar ensembles. Conclusions: We conclude that iterative BAS in combination with objective function surrogates can be a viable option to implement automated BAS at clinically acceptable computation times. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:1073 / 1082
页数:10
相关论文
共 50 条
  • [41] Knowledge based Automatic Beam Angle Determination for Lung IMRT Planning
    Yuan, L.
    Ge, Y.
    Sheng, Y.
    Yin, F.
    Wu, Q. J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 440 - 443
  • [42] Beam angle optimization in IMRT: are we really optimizing what matters?
    Rocha, Humberto
    Dias, Joana Matos
    Ventura, Tiago
    Ferreira, Brigida da Costa
    Lopes, Maria do Carmo
    INTERNATIONAL TRANSACTIONS IN OPERATIONAL RESEARCH, 2019, 26 (03) : 908 - 928
  • [43] Iterative Optimization Using Normalized Transmission Map for IMRT With Arbitrary Beam Profiles
    Choi, K.
    Suh, T.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S796 - S796
  • [44] Iterative Optimization of Normalized Transmission Maps for IMRT Using Arbitrary Beam Profiles
    Choi, K.
    Suh, T.
    Xing, L.
    MEDICAL PHYSICS, 2012, 39 (06) : 3919 - 3920
  • [45] A Beam Angle Selection Algorithm for Particle Therapy
    Cabal, G.
    Luan, S.
    Jakel, O.
    MEDICAL PHYSICS, 2010, 37 (06) : 3290 - +
  • [46] AN ALGORITHM FOR BEAM ANGLE SELECTION IN HADRON THERAPY
    Arango, G. A. Cabal
    Luan, T.
    Jaekel, O.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S533 - S533
  • [47] Characterizing the combinatorial beam angle selection problem
    Bangert, Mark
    Ziegenhein, Peter
    Oelfke, Uwe
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20): : 6707 - 6723
  • [48] Iterative Best Beam Selection for Random Unitary Beamforming
    Son, Hyukmin
    Lee, Sanghoon
    IEEE TRANSACTIONS ON COMMUNICATIONS, 2011, 59 (04) : 968 - 974
  • [49] Is there an optimal starting gantry angle for equiangular-spaced beam arrangements in IMRT?
    Potrebko, P.
    McCurdy, B.
    MEDICAL PHYSICS, 2006, 33 (07) : 2659 - 2659
  • [50] Genetic algorithm based automatic beam angles selection in IMRT planning
    Li, YJ
    Yao, J
    Yao, DZ
    MEDICAL PHYSICS, 2003, 30 (06) : 1373 - 1373