Accelerated iterative beam angle selection in IMRT

被引:18
|
作者
Bangert, Mark [1 ]
Unkelbach, Jan [2 ,3 ]
机构
[1] German Canc Res Ctr, Dept Med Phys Radiat Oncol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
intensity-modulated radiation therapy; treatment planning; beam angle selection; MODULATED RADIATION-THERAPY; ORIENTATION OPTIMIZATION; RADIOTHERAPY; GENERATION; PERFORMANCE; NUMBER; TUMORS; PLANS;
D O I
10.1118/1.4940350
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Iterative methods for beam angle selection (BAS) for intensity-modulated radiation therapy (IMRT) planning sequentially construct a beneficial ensemble of beam directions. In a naive implementation, the nth beam is selected by adding beam orientations one-by-one from a discrete set of candidates to an existing ensemble of (n-1) beams. The best beam orientation is identified in a time consuming process by solving the fluence map optimization (FMO) problem for every candidate beam and selecting the beam that yields the largest improvement to the objective function value. This paper evaluates two alternative methods to accelerate iterative BAS based on surrogates for the FMO objective function value. Methods: We suggest to select candidate beams not based on the FMO objective function value after convergence but (1) based on the objective function value after five FMO iterations of a gradient based algorithm and (2) based on a projected gradient of the FMO problem in the first iteration. The performance of the objective function surrogates is evaluated based on the resulting objective function values and dose statistics in a treatment planning study comprising three intracranial, three pancreas, and three prostate cases. Furthermore, iterative BAS is evaluated for an application in which a small number of noncoplanar beams complement a set of coplanar beam orientations. This scenario is of practical interest as noncoplanar setups may require additional attention of the treatment personnel for every couch rotation. Results: Iterative BAS relying on objective function surrogates yields similar results compared to naive BAS with regard to the objective function values and dose statistics. At the same time, early stopping of the FMO and using the projected gradient during the first iteration enable reductions in computation time by approximately one to two orders of magnitude. With regard to the clinical delivery of noncoplanar IMRT treatments, we could show that optimized beam ensembles using only a few noncoplanar beam orientations often approach the plan quality of fully noncoplanar ensembles. Conclusions: We conclude that iterative BAS in combination with objective function surrogates can be a viable option to implement automated BAS at clinically acceptable computation times. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:1073 / 1082
页数:10
相关论文
共 50 条
  • [21] IMRT Beam Angle Optimization using Differential Evolution
    Dias, Joana
    Rocha, Humberto
    Ferreira, Brigida
    Lopes, Maria do Carmo
    2014 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2014,
  • [22] Beam angle selection for intensity-modulated radiotherapy (IMRT) treatment of unresectable pancreatic cancer: are noncoplanar beam angles necessary?
    D. S. Chang
    G. K. Bartlett
    I. J. Das
    H. R. Cardenes
    Clinical and Translational Oncology, 2013, 15 : 720 - 724
  • [23] Evaluation of a systematic beam direction selection algorithm for IMRT
    Gaede, S
    Wong, E
    Rasmussen, H
    MEDICAL PHYSICS, 2002, 29 (06) : 1335 - 1335
  • [24] Lung IMRT planning with automatic determination of beam angle configurations
    Yuan, Lulin
    Zhu, Wei
    Ge, Yaorong
    Jiang, Yuliang
    Sheng, Yang
    Yin, Fang-Fang
    Wu, Q. Jackie
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (13):
  • [25] Integrated beam angle optimization in IMRT autoplanning for lung cancer
    Fjellanger, K.
    Hysing, L. B.
    Heijmen, B. J. M.
    Pettersen, H. E. S.
    Sandvik, I. M.
    Sulen, T. H.
    Breedveld, S.
    Rossi, L.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S643 - S644
  • [26] A Global Score-Driven Beam Angle Optimization in IMRT
    Rocha, Humberto
    Dias, Joana M.
    Ventura, Tiago
    Ferreira, Brigida C.
    Lopes, Maria do Carmo
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2017, PT III, 2017, 10406 : 77 - 90
  • [27] Inverse Beam Angle Optimization in IMRT for Lung Cancer Patients
    Pan, X.
    Zhang, X.
    Li, Y.
    Li, X.
    Chang, J.
    Zhu, X.
    Mohan, R.
    MEDICAL PHYSICS, 2010, 37 (06) : 3341 - +
  • [28] A nested partitions framework for beam angle and dose optimization in IMRT
    Nazareth, D.
    Zhang, H.
    Meyer, R.
    Shi, L.
    D'Souza, W.
    MEDICAL PHYSICS, 2006, 33 (06) : 2056 - 2057
  • [29] 4pi Non-Coplanar IMRT Beam Angle Selection by Convex Optimization with Group Sparsity Penalty
    O'Connor, D.
    Voronenko, Y.
    Nguyen, D.
    Yin, W.
    Sheng, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3895 - 3895
  • [30] Using Deep Neural Network for Beam Angle Selection in 4p IMRT Planning of Patients with Lung Cancer
    Barkousaraie, A.
    Lin, M.
    Jiang, S.
    Nguyen, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E452 - E452