A CEA Concentration Measurement System Using FPW Biosensors and Frequency-shift Readout IC

被引:0
|
作者
Wang, Chua-Chin [1 ]
Sung, Tzu-Chiao [1 ]
Liao, Chiang-Hsiang [1 ]
Chang, Chia-Ming [1 ]
Lan, Je-Wei [1 ]
Huang, I-Yu [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Elect Engn, Kaohsiung 80424, Taiwan
关键词
CEA concentration; frequency-shift readout circuit; FPW biosensor; peak detector; IGE;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a CEA (carcinoembryonic antigen) concentration measurement system using flexural plate wave (FPW) biosensors and a frequency-shift readout IC is presented. The proposed frequency-shift readout method employs a programmable frequency generator and a peak detecting scheme to estimate the resonant frequency. The programmable frequency generator provides a frequency scanning range from 0.9 MHz to 25 MHz according to the characteristics of the FPW biosensors. Particularly, the proposed frequency-shift readout circuit filters and amplifies the FPW biosensors signals such that the requirements for the following voltage peak detector can be relaxed. Therefore, the sensitivity and performance of the CEA sensing system are also enhanced. The sensitivity of the peak detector is 5 mV at the highest signal rate, 50 MHz. The proposed frequency-shift readout circuit is implemented using a typical 0.18 mu m CMOS technology. The power consumption of the proposed CEA concentration measurement system is 7.69 mW justified by HSPICE simulations.
引用
收藏
页码:27 / 30
页数:4
相关论文
共 50 条
  • [1] A Novel Frequency-shift Readout System for CEA Concentration Detection Application
    Wang, Deng-Shian
    Liu, Yun-Shen
    Wang, Chua-Chin
    2016 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC), 2016, : 133 - 134
  • [2] A Protein Concentration Measurement System Using a Flexural Plate-Wave Frequency-Shift Readout Technique
    Wang, Chua-Chin
    Sung, Tzu-Chiao
    Hsu, Chia-Hao
    Tsai, Yue-Da
    Chen, Yun-Chi
    Lee, Ming-Chih
    Huang, I-Yu
    SENSORS, 2013, 13 (01) : 86 - 105
  • [3] A Power-efficient, Wide-frequency-range Impedance Measurement IC Using Frequency-shift Technique
    Cheon, Song-, I
    Kweon, Soon-Jae
    Kim, Youngin
    Ha, Sohmyung
    Je, Minkyu
    2021 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2021,
  • [4] MEASUREMENT OF FREQUENCY-SHIFT IN A GYROTRON OSCILLATOR
    JONES, RM
    LINDSAY, PA
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1986, 61 (06) : 937 - 951
  • [5] A Frequency-shift Readout System with Offset Cancellation OPA for Portable Devices of Marijuana Detection
    Huang, Hao-Chun
    Wang, Deng-Shian
    Wang, Chua-Chin
    2018 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2018,
  • [6] A Polar-Demodulation-Based Impedance-Measurement IC Using Frequency-Shift Technique With Low Power Consumption and Wide Frequency Range
    Cheon, Song-, I
    Kweon, Soon-Jae
    Kim, Youngin
    Koo, Jimin
    Ha, Sohmyung
    Je, Minkyu
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2021, 15 (06) : 1210 - 1220
  • [7] OPERATION OF A FREQUENCY-SHIFT IN A FEEDBACK-SYSTEM
    HEINY, F
    FREQUENZ, 1978, 32 (10) : 276 - 290
  • [8] A Fast FPW-based Protein Concentration Measurement System
    Wang, Chua-Chin
    Hsu, Chia-Hao
    Tsai, Yue-Da
    Chen, Yun-Chi
    Lee, Ming-Chih
    Huang, I-Yu
    2012 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 2012), 2012, : 2389 - 2392
  • [9] An ultraviolet laser communication system using frequency-shift keying modulation scheme
    彭帝永
    施军
    彭光辉
    肖沙里
    徐山河
    王珊
    刘锋
    OptoelectronicsLetters, 2015, 11 (01) : 65 - 68
  • [10] An ultraviolet laser communication system using frequency-shift keying modulation scheme
    Peng D.-Y.
    Shi J.
    Peng G.-H.
    Xiao S.-L.
    Xu S.-H.
    Wang S.
    Liu F.
    Optoelectronics Letters, 2015, 11 (01) : 65 - 68