A CEA Concentration Measurement System Using FPW Biosensors and Frequency-shift Readout IC

被引:0
|
作者
Wang, Chua-Chin [1 ]
Sung, Tzu-Chiao [1 ]
Liao, Chiang-Hsiang [1 ]
Chang, Chia-Ming [1 ]
Lan, Je-Wei [1 ]
Huang, I-Yu [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Elect Engn, Kaohsiung 80424, Taiwan
关键词
CEA concentration; frequency-shift readout circuit; FPW biosensor; peak detector; IGE;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a CEA (carcinoembryonic antigen) concentration measurement system using flexural plate wave (FPW) biosensors and a frequency-shift readout IC is presented. The proposed frequency-shift readout method employs a programmable frequency generator and a peak detecting scheme to estimate the resonant frequency. The programmable frequency generator provides a frequency scanning range from 0.9 MHz to 25 MHz according to the characteristics of the FPW biosensors. Particularly, the proposed frequency-shift readout circuit filters and amplifies the FPW biosensors signals such that the requirements for the following voltage peak detector can be relaxed. Therefore, the sensitivity and performance of the CEA sensing system are also enhanced. The sensitivity of the peak detector is 5 mV at the highest signal rate, 50 MHz. The proposed frequency-shift readout circuit is implemented using a typical 0.18 mu m CMOS technology. The power consumption of the proposed CEA concentration measurement system is 7.69 mW justified by HSPICE simulations.
引用
收藏
页码:27 / 30
页数:4
相关论文
共 50 条
  • [21] A Fast Power Grid Frequency Estimation Approach Using Frequency-Shift Filtering
    Li, Jianmin
    Teng, Zhaosheng
    Wang, Yajun
    You, Shutang
    Liu, Yilu
    Yao, Wenxuan
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (03) : 2461 - 2464
  • [22] LASER-COOLED CS FREQUENCY STANDARD AND A MEASUREMENT OF THE FREQUENCY-SHIFT DUE TO ULTRACOLD COLLISIONS
    GIBBLE, K
    CHU, S
    PHYSICAL REVIEW LETTERS, 1993, 70 (12) : 1771 - 1774
  • [23] Multiple particle identification by sequential frequency-shift measurement of a micro-plate
    Ma, Shujun
    Li, Muxin
    Wang, Shiliang
    Liu, Hui
    Wang, Hao
    Ren, Lei
    Huang, Minghao
    Zhang, Xinwen
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2022, 231
  • [24] MEASUREMENT OF THE FREQUENCY-SHIFT DUE TO DISTRIBUTED CAVITY PHASE DIFFERENCE IN AN ATOMIC CLOCK
    BAUCH, A
    HEINDORFF, T
    SCHROEDER, R
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1985, 34 (02) : 136 - 138
  • [25] MEASUREMENT OF DOPPLER FREQUENCY-SHIFT OF VHF RADAR ECHOES FROM METEOR TRAILS
    INDUKUMAR, S
    REDDI, CR
    SIMON, EK
    INDIAN JOURNAL OF RADIO & SPACE PHYSICS, 1987, 16 (04): : 306 - 312
  • [26] A NEW FREQUENCY-SHIFT TECHNIQUE FOR INSTANTANEOUS PULSE-ECHO ATTENUATION MEASUREMENT
    HO, JSC
    SMITH, KC
    HUNT, JW
    ULTRASONIC IMAGING, 1986, 8 (01) : 52 - 53
  • [27] Measurement of the Biotin Concentration Using QCM Biosensors
    Chang, Yaw-Jen
    Liao, Chia-Chen
    Chang, Cheng-Hao
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1187 - 1190
  • [28] ORGAN TEMPERATURE-MEASUREMENT IN A MICROWAVE-OVEN BY RESONANCE FREQUENCY-SHIFT
    COOPER, D
    KETTERER, F
    HOLST, H
    CRYOBIOLOGY, 1981, 18 (04) : 378 - 385
  • [29] Automatic Frequency-Shift Detection in the Auditory System: A Review of Psychophysical Findings
    Demany, Laurent
    Semal, Catherine
    NEUROSCIENCE, 2018, 389 : 30 - 40
  • [30] MEASUREMENT OF THE FREQUENCY-SHIFT DUE TO DISTRIBUTED CAVITY PHASE DIFFERENCE IN AN ATOMIC CLOCK.
    Bauch, Andreas
    Heindorff, Thomas
    Schroeder, Roland
    IEEE Transactions on Instrumentation and Measurement, 1984, IM-34 (02)