A Polar-Demodulation-Based Impedance-Measurement IC Using Frequency-Shift Technique With Low Power Consumption and Wide Frequency Range

被引:10
|
作者
Cheon, Song-, I [1 ]
Kweon, Soon-Jae [2 ]
Kim, Youngin [1 ]
Koo, Jimin [1 ]
Ha, Sohmyung [2 ,3 ]
Je, Minkyu [1 ]
机构
[1] Korea Adv Inst Sci & Technol KAIST, Sch Elect Engn, Daejeon 34141, South Korea
[2] New York Univ Abu Dhabi, Div Engn, Abu Dhabi 129188, U Arab Emirates
[3] New York Univ, Tandon Sch Engn, New York, NY 10003 USA
基金
新加坡国家研究基金会;
关键词
Analog front-end; auto-zeroing technique; bioimpedance; electrical impedance spectroscopy (EIS); frequency-shift technique; polar demodulator; CMOS CURRENT DRIVER; MEASUREMENT CHIP;
D O I
10.1109/TBCAS.2021.3135836
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we present a new impedance measurement integrated circuit (IC) for achieving a wideband coverage up to 10 MHz and low power consumption. A frequency-shift technique is applied to down-shift the input frequency, which ranges from 100 kHz to 10 MHz, into an intermediate frequency of 10 kHz, while the frequency-shifting is bypassed when the input frequency falls in the range from 100 Hz to 100 kHz. It results in 100 times relaxation of the requirement on the instrumentation amplifier (IA) bandwidth and the comparator delay, greatly reducing overall power consumption. The proposed IC employs the polar demodulation structure with a reference resistor that provides reference timing information avoiding any synchronization issue with the transmitter. In order to compensate for the comparator delay and nonlinearity of the IA, the reference magnitude measurement path is added, making only the mismatch of the circuit affects the accuracy. This allows for employing the auto-zeroing technique that can remove the offset but increase the absolute delay by using an additional capacitor to the comparator. The chip fabricated in a 0.18-mu m CMOS technology consumes the power of 756 mu W while covering the measurement frequency range from 100 Hz to 10 MHz and exhibiting the maximum magnitude and phase errors of 1.1% and 1.9 degrees, respectively.
引用
收藏
页码:1210 / 1220
页数:11
相关论文
共 50 条
  • [1] A Power-efficient, Wide-frequency-range Impedance Measurement IC Using Frequency-shift Technique
    Cheon, Song-, I
    Kweon, Soon-Jae
    Kim, Youngin
    Ha, Sohmyung
    Je, Minkyu
    2021 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2021,
  • [2] A CEA Concentration Measurement System Using FPW Biosensors and Frequency-shift Readout IC
    Wang, Chua-Chin
    Sung, Tzu-Chiao
    Liao, Chiang-Hsiang
    Chang, Chia-Ming
    Lan, Je-Wei
    Huang, I-Yu
    2013 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC), 2013, : 27 - 30
  • [3] Wide Frequency Range Impedance Measurement of a Li-ion Prismatic Cell for Power Line Communication Technique
    Talei, Arash Pake
    Pribyl, Wolfgang A.
    Hofer, Guenter
    2019 16TH INTERNATIONAL CONFERENCE ON SYNTHESIS, MODELING, ANALYSIS AND SIMULATION METHODS AND APPLICATIONS TO CIRCUIT DESIGN (SMACD 2019), 2019, : 109 - 112
  • [4] PHASE-SHIFT AND POWER-FACTOR MEASUREMENT FOR A WIDE FREQUENCY-RANGE USING ROM
    BAKOS, NS
    ABDULHAMEED, KH
    ALTIKRITI, MN
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1988, 64 (02) : 299 - 304
  • [5] Low power consumption and wide locking-range frequency divider by two
    Wu, Janne-Wha
    Tu, Chih-Ho
    Wu, Jheng-Wei
    Chen, Sheng-Wen
    Kao, Peng
    Hsu, Kai-Cheng
    2014 9TH EUROPEAN MICROWAVE INTEGRATED CIRCUIT CONFERENCE (EUMIC), 2014, : 77 - 79
  • [6] A low power LDO with high PSR over a wide frequency range based on an impedance attenuation buffer
    Pei, Jiajian
    Sun, Ping
    Li, Shijun
    Xiao, Yao
    Cai, Jianfeng
    IEICE ELECTRONICS EXPRESS, 2024, 21 (06):
  • [7] High-frequency electric field intensity measurement based on frequency shift with high gain and wide frequency range
    Lin, Feihong
    Wang, Xihao
    Tang, Mingwei
    Zhang, Jiqiang
    Wang, Lining
    Liu, Xu
    Yang, Qing
    OPTICS COMMUNICATIONS, 2023, 545
  • [8] An Improved Method for Frequency-Shift Measurement Dynamic Range Based on Phase-Modulated Doppler Lidar
    Du Jun
    Cheng Ya
    Zhang Xiaoxiao
    Yang Na
    Qu Yanchen
    ACTA OPTICA SINICA, 2020, 40 (06)
  • [9] An Improved Method for Frequency-Shift Measurement Dynamic Range Based on Phase-Modulated Doppler Lidar
    Du J.
    Cheng Y.
    Zhang X.
    Yang N.
    Qu Y.
    Guangxue Xuebao/Acta Optica Sinica, 2020, 40 (06):
  • [10] MEASUREMENT OF ELECTRODE IMPEDANCE IN A WIDE FREQUENCY RANGE USING A PSEUDO-RANDOM NOISE
    BLANC, G
    EPELBOIN, I
    GABRIELLI, C
    KEDDAM, M
    ELECTROCHIMICA ACTA, 1975, 20 (08) : 599 - 601