摘要
Single-storey steel structures represent the vast majority of buildings that are constructed for light industrial, commercial and recreational uses in North America. It is often more cost effective to specify a non-ductile structural system, despite the fact that this type of structure and its occupants would be more vulnerable to seismic ground motions. The overall objective of this research is to investigate the possibility of allowing the metal roof deck diaphragm to absorb earthquake induced energy through plastic deformation. This paper provides preliminary information on the inelastic cyclic response, including load vs, displacement hysteresis and energy absorption capacity, of screwed, nailed (powder-actuated fasteners) and welded steel deck-to-structure connections. The results of monotonic, cyclic and quasi-static tests revealed that the type of connection influences the ultimate capacity and ability to dissipate energy.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 50 条
  • [41] Linear and nonlinear seismic response of a 52-storey steel frame building
    Ventura, CE
    Ding, YM
    STRUCTURAL DESIGN OF TALL BUILDINGS, 2000, 9 (01): : 25 - 45
  • [42] Seismic Response of Resilient Steel Frame with Self-Centering SMA Brace
    Shujun Hu
    Liqing Chang
    Bo Zhang
    Sizhi Zeng
    Fenghua Tang
    Qing Zhi
    International Journal of Steel Structures, 2023, 23 : 1587 - 1601
  • [43] Seismic response of steel frame buildings to near-source ground motions
    Hall, JF
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1998, 27 (12): : 1445 - 1464
  • [44] Analysis of Steel Braced Frame Structure Response Encountered Higher Seismic Intensity
    Li Ming
    Liu Yongfang
    Jia Lianguang
    Liu Yong
    Du Jingfeng
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 1117 - +
  • [45] Cyclic loading tests of connection between RC frame and steel roof study of connection between rc frame and steel roof part 1
    Yamada, Satoshi
    Shimada, Yuko
    Tomatsu, Kazuki
    Shirai, Yuki
    Matsumoto, Yuka
    Hasegawa, Takashi
    Mukai, Tomohisa
    Takeuchi, Toru
    Journal of Structural and Construction Engineering, 2014, 79 (705): : 1687 - 1697
  • [46] Optimal Design of Multiple Tuned Mass Dampers for Seismic Control of an Inelastic Steel Moment-Resisting Frame
    Bilondi, Mohammad Reza Shayesteh
    Khatibinia, Mohsen
    Najafi, Mona
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2023, 47 (06) : 3465 - 3485
  • [47] Optimal Design of Multiple Tuned Mass Dampers for Seismic Control of an Inelastic Steel Moment-Resisting Frame
    Mohammad Reza Shayesteh Bilondi
    Mohsen Khatibinia
    Mona Najafi
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2023, 47 : 3465 - 3485
  • [48] SEISMIC RESPONSE OF INELASTIC STRUCTURES.
    Sharpe, R.D.
    Carr, A.J.
    Bulletin of the New Zealand Society for Earthquake Engineering, 1975, 8 (03): : 192 - 203
  • [49] Multiple inelastic mechanisms analysis (MIMA): A simplified method for the estimation of the seismic response of RC frame buildings
    Cardone, Donatello
    Flora, Amedeo
    ENGINEERING STRUCTURES, 2017, 145 : 368 - 380
  • [50] Inelastic torsional seismic response of nominally symmetric reinforced concrete frame structures: Shaking table tests
    Benavent-Climent, A.
    Morillas, L.
    Escolano-Margarit, D.
    ENGINEERING STRUCTURES, 2014, 80 : 109 - 117