Inelastic seismic response of frame fasteners for steel roof decks

被引:0
|
作者
Rogers, CA [1 ]
Tremblay, R [1 ]
机构
[1] McGill Univ, Dept Civil Engn & Appl Mech, Montreal, PQ H3A 2K6, Canada
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Single-storey steel structures represent the vast majority of buildings that are constructed for light industrial, commercial and recreational uses in North America. It is often more cost effective to specify a non-ductile structural system, despite the fact that this type of structure and its occupants would be more vulnerable to seismic ground motions. The overall objective of this research is to investigate the possibility of allowing the metal roof deck diaphragm to absorb earthquake induced energy through plastic deformation. This paper provides preliminary information on the inelastic cyclic response, including load vs, displacement hysteresis and energy absorption capacity, of screwed, nailed (powder-actuated fasteners) and welded steel deck-to-structure connections. The results of monotonic, cyclic and quasi-static tests revealed that the type of connection influences the ultimate capacity and ability to dissipate energy.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 50 条
  • [21] Regression models for predicting the inelastic seismic response of steel braced frames
    Hickey, John
    Broderick, Brian
    Journal of Constructional Steel Research, 2022, 194
  • [22] Regression models for predicting the inelastic seismic response of steel braced frames
    Hickey, John
    Broderick, Brian
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 194
  • [23] Seismic response of a steel frame considering the underground subway-soft soil-steel frame interaction
    Zhang, Haiying
    Lu, Jinyu
    Shu, Haigang
    Jiang, Haorui
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [24] MATHEMATICAL-MODEL TO PREDICT INELASTIC RESPONSE OF A STEEL FRAME - FORMULATION OF MODEL
    MCNIVEN, HD
    MATZEN, VC
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1978, 6 (02): : 189 - 202
  • [25] INELASTIC SEISMIC RESPONSE OF CODE-DESIGNED MULTISTORY FRAME BUILDINGS WITH REGULAR ASYMMETRY
    DUAN, XN
    CHANDLER, AM
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1993, 22 (05): : 431 - 445
  • [26] Inelastic Seismic Response of Concrete Frame Structures Reinforced with High Strength Steel Bars Under Bi-directional Earthquake Inputs
    Wei, Feng
    Zhang, Sifan
    Zhang, Wei
    Su, Cheng
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2022, 54 (06): : 212 - 221
  • [27] Seismic response and damage limit of concrete filled steel tube frame
    Goto, K.
    TUBULAR STRUCTURES XIV, 2012, : 533 - 539
  • [28] Seismic response of steel frame structures with hybrid passive control systems
    Marshall, Justin D.
    Charney, Finley A.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (04): : 715 - 733
  • [29] Seismic response of linked column steel braced frame with mechanical springs
    Li, Feng
    Zhao, Bao-Cheng
    Li, Ying-Min
    Wang, Guo-Jue
    STRUCTURES, 2023, 53 : 240 - 252
  • [30] Influence of connection design on the inelastic seismic response of HSS steel bracing members
    Department of Civil, Geological and Mining Engineering, Ecole Polytechnique, Montreal, Canada
    Weld. World, 2006, SPEC. ISS. (574-581):