Design of a Learning Cascade Controller for a Continuous Noninvasive Blood Pressure Measurement System

被引:0
|
作者
Seel, Thomas [1 ]
Schneider, Sarah [2 ]
Affeld, Klaus [2 ]
Schauer, Thomas [1 ]
机构
[1] Tech Univ Berlin, Fachgebiet Regelungssyst, D-10587 Berlin, Germany
[2] Charite, Lab Biofluidmech, D-13353 Berlin, Germany
关键词
Cascade control; system identification; iterative learning control; blood pressure measurement; biomedical engineering;
D O I
10.1515/auto-2014-1130
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
For a novel blood pressure measurement system, we design a cascaded controller that consists of two classic feedback loops and an iterative learning algorithm. We show that the bandwidth of the feedback loops is limited by the measurement noise of the ultrasound sensor and that this restriction can be circumvented by exploiting the repetitive nature of the disturbance that is induced by the oscillating arterial pressure.
引用
收藏
页码:5 / 13
页数:9
相关论文
共 50 条
  • [21] The Reliability of Continuous Noninvasive Finger Blood Pressure Measurement in Critically III Children
    Lemson, Joris
    Hofhuizen, Charlotte M.
    Schraa, Olaf
    Settels, Jos J.
    Scheffer, Gert Jan
    van der Hoeven, Johannes G.
    ANESTHESIA AND ANALGESIA, 2009, 108 (03): : 814 - 821
  • [22] Noninvasive continuous blood pressure monitoring using microelectromechanical system technology
    Satake, Shuichi
    Shimura, Tatsuo
    Ono, Tetsuya
    Shimomura, Kenju
    Takenoshita, Seiichi
    Kono, Koji
    BLOOD PRESSURE MONITORING, 2019, 24 (03) : 155 - 159
  • [23] Noninvasive Blood Pressure Measurement in Neonates
    Solevag, Anne Lee
    Saugstad, Ola Didrik
    JOURNAL OF PEDIATRICS, 2021, 235 : 57 - 57
  • [24] Design of a Continuous Blood Pressure Measurement System Based on Pulse Wave and ECG Signals
    Li, Jian-Qiang
    Chen, Zhuang-Zhuang
    Deng, Gen-Qiang
    Wang, Huihui
    Mavromoustakis, Constandinos X.
    Song, Houbing
    Ming, Zhong
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2018, 6 : 1 - 14
  • [25] NONINVASIVE BLOOD-PRESSURE MEASUREMENT
    SANFORD, TJ
    JONES, BR
    SMITH, NT
    ANESTHESIOLOGY CLINICS OF NORTH AMERICA, 1988, 6 (04): : 721 - 741
  • [26] A deep learning method for continuous noninvasive blood pressure monitoring using photoplethysmography
    Liang, Hao
    He, Wei
    Xu, Zheng
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (05)
  • [27] Design of noninvasive arterial blood pressure measurement system by using double-cuffs oscillometric method
    Lee, Pil-Jae
    Lee, Young-Jae
    Kim, Dong-Jun
    Lee, Jae-Ho
    Lim, Min-Gyu
    Lee, Jeong-Whan
    Transactions of the Korean Institute of Electrical Engineers, 2012, 61 (06): : 885 - 890
  • [28] Continuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship Between Blood Pressure and Pulse Wave Velocity
    Chen, Yan
    Wen, Changyun
    Tao, Guocai
    Bi, Min
    Li, Guoqi
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (11) : 2222 - 2233
  • [29] Continuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship Between Blood Pressure and Pulse Wave Velocity
    Yan Chen
    Changyun Wen
    Guocai Tao
    Min Bi
    Guoqi Li
    Annals of Biomedical Engineering, 2009, 37 : 2222 - 2233
  • [30] ORTHOSTATIC CIRCULATORY CONTROL IN THE ELDERLY EVALUATED BY NONINVASIVE CONTINUOUS BLOOD-PRESSURE MEASUREMENT
    IMHOLZ, BPM
    DAMBRINK, JHA
    KAREMAKER, JM
    WIELING, W
    CLINICAL SCIENCE, 1990, 79 (01) : 73 - 79