Research and Design on the on-line Monitoring for Rainwater Leakage of Floors on Substation Roofs

被引:0
|
作者
Tang, Xin [1 ]
Chen, Gang [1 ]
Hu, Bin [1 ]
Zhang, Jinbo [2 ]
Chen, Bin [2 ]
Lu, Shuai [2 ]
机构
[1] Jiaxing State Grid, Jiaxing, Zhejiang, Peoples R China
[2] Hohai Univ, Coll Internet Things Engn, Changzhou, Jiangsu, Peoples R China
来源
PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING (SEEE 2015) | 2015年 / 14卷
关键词
substation; roof; rainwater leakage; plate condenser; on-line monitoring;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to reduce the safety loophole for substation caused by rainwater leakage of roof, this paper proposed an on-line monitoring for rainwater leakage of substation roof based on a parallel plate capacitor sensor. This method is based on the capacitance sensor in the composition of installed metal plate between slabs, when there is rainwater leakage in the floor, medium of capacitance will change obviously, and it can judge that whether the floor rainwater leakage occurs according to the characteristics. With the above principle, this paper designed an on-line monitoring device for rainwater leakage of substation roof. The practical test showed that the device has the advantages of usableness, low cost and accurate judgement. It can satisfy the requirement of the substation roof rainwater leakage monitoring.
引用
收藏
页码:96 / 98
页数:3
相关论文
共 50 条
  • [21] Improvement of On-line Monitoring Method for Insulation of Substation DC System
    Lei Xing
    Xu Nan
    Shen Wei
    Dai Chunyi
    Xu Zhaode
    2015 IEEE INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2015, : 1350 - 1355
  • [22] Automated testing of substation on-line monitoring intelligent electronic device
    Wang, Dewen
    Ge, Liang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2014, (14): : 84 - 89
  • [23] The design of synchronous sampling unit in on-line resistive leakage current monitoring system of MOA
    Wang, YQ
    Lu, FC
    Li, HM
    Li, YQ
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 472 - 475
  • [24] Long term on-line PD monitoring using power line communication in a distribution substation
    Houdai, Akito
    Lumba, Lunnetta Safura
    Wakisaka, Toshiyuki
    Kozako, Masahiro
    Hikita, Masayuki
    Sato, Hidefumi
    Soeda, Masahiro
    2022 9TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2022, : 649 - 653
  • [25] Advantage of On-Line Partial Discharge Continuous Monitoring of Medium Voltage Substation
    Blokhintsev, Igor
    Patterson, Calvin L.
    Cassidy, Brian J.
    Loesch, Armin H.
    2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 153 - +
  • [26] Research and Design of Power-supply Coil for On-line Monitoring System
    Fan, Wenbo
    Guan, Shilei
    Lei, Haoliang
    Tang, Kexin
    Xin, Qian
    Zhang, Kun
    Yan, Jing
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 1016 - 1019
  • [27] Research on monitoring of winding deformation of power transformer by on-line parameter estimation about leakage inductance
    Li Peng
    Zhang Bao-Hui
    Hao Zhi-Guo
    Hu Xiao-Jing
    Chu Yun-Long
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 1375 - +
  • [28] Research on on-line monitoring of waterwall slagging
    Yu, HM
    Sun, BM
    Xu, H
    Bai, J
    Wang, CW
    Meng, LC
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 687 - 693
  • [29] Influence of interphase interference to on-line leakage current monitoring of MOA
    Wang, YQ
    Lu, FC
    Li, HM
    2004 4th INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, 2004, : 916 - 919
  • [30] Research on on-line monitoring system for transmission line condition
    Cheng, Jian
    Cheng, Tengbiao
    Luo, Zhiyi
    Zhan, Weipeng
    Zhan, Wendong
    Paper Asia, 2018, COMPENDIUM 1 (08): : 69 - 72