Advantage of On-Line Partial Discharge Continuous Monitoring of Medium Voltage Substation

被引:9
|
作者
Blokhintsev, Igor [1 ]
Patterson, Calvin L. [2 ]
Cassidy, Brian J. [3 ]
Loesch, Armin H. [4 ]
机构
[1] Eaton Corp, 5421 Feltl Rd Ste 190, Minnetonka, MN 55343 USA
[2] Eaton Corp, Saskatoon S7J 4V3, SK, Canada
[3] Bayer Mat Sci, Baytown, TX 77520 USA
[4] Eaton Corp, Houston, TX 77075 USA
关键词
D O I
10.1109/EIC.2009.5166335
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
On-Line Continuous Partial Discharge measurements of medium voltage substations have not attracted the same attention in the electrical community as compared to similar PD measurements of rotating machines. The cost of an unexpected outage however may be considerably more significant of a main distribution bus than just for a single motor failure. This paper discusses pros and cons of PD measurements using multiple sensors for additional noise reduction and localizing PD activity for measurements made in higher frequency bands. The importance of continuous PD monitoring vs. periodic walk in PD, measurements of switchgear is also discussed considering that PD activity in switchgear can have very unstable activity highly dependent on ambient conditions. Negative periodic PD tests in switchgear can result in a false sense of security. Case studies from field experience are presented to support the discussions.
引用
收藏
页码:153 / +
页数:2
相关论文
共 50 条
  • [1] CONTINUOUS ON-LINE PARTIAL DISCHARGE MONITORING OF MEDIUM VOLTAGE SUBSTATIONS
    Benzing, Joel
    Blokhintsev, Igor
    Patterson, Calvin
    Loesch, Armin
    Cassidy, Brian J.
    [J]. CONFERENCE RECORD OF 2012 ANNUAL IEEE PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE (PPIC), 2012,
  • [2] CONTINUOUS ON-LINE PARTIAL DISCHARGE MONITORING OF MEDIUM VOLTAGE SUBSTATIONS
    Benzing, Joel
    Patterson, Calvin L.
    Cassidy, Brian J.
    Blokhintsev, Igor
    Loesch, Armin H.
    [J]. 2012 IEEE-IAS/PCA 54TH CEMENT INDUSTRY TECHNICAL CONFERENCE, 2012,
  • [3] Development of a continuous on-line partial discharge monitoring system for medium voltage motors
    Stone, GC
    Campbell, SR
    Sedding, HG
    [J]. EIGHTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND DRIVES, 1997, (444): : 123 - 127
  • [4] On-line partial discharge monitoring in medium voltage underground cables
    Zhou, C.
    Michel, M.
    Hepburn, D. M.
    Song, X.
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2009, 3 (05) : 354 - 363
  • [5] On-line Partial Discharge Monitoring of Substation Power Transformers
    Huzmezan, Mihai
    [J]. 2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 347 - 352
  • [6] Continuous on-line partial discharge monitoring of power generators
    Kheirmand, A
    Leijon, M
    [J]. IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 496 - 499
  • [7] Continuous and Remote Monitoring of Partial Discharge in Medium Voltage Switchgear
    Blokhintsev, Igor
    Kozusko, Jim
    Oberer, Brian
    Anzaldi, David
    [J]. 2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 205 - 208
  • [8] Continuous on-line partial discharge monitoring of generator stator windings
    Lloyd, BA
    Campbell, SR
    Stone, GC
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) : 1131 - 1137
  • [9] Continuous on-line monitoring of partial discharges in high voltage cables
    Tian, Y
    Lewin, PL
    Wilkinson, JS
    Sutton, SJ
    Swingler, SG
    [J]. CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 454 - 457
  • [10] An On-line Monitoring System for Partial Discharge from High Voltage Transformer
    王哲
    陈学允
    蔡惟铮
    [J]. Journal of Harbin Institute of Technology(New series), 1998, (02) : 52 - 56