CONTINUOUS ON-LINE PARTIAL DISCHARGE MONITORING OF MEDIUM VOLTAGE SUBSTATIONS

被引:0
|
作者
Benzing, Joel [1 ]
Patterson, Calvin L. [1 ]
Cassidy, Brian J. [2 ]
Blokhintsev, Igor [1 ]
Loesch, Armin H. [1 ]
机构
[1] Eaton Corp, Cleveland, OH 44114 USA
[2] Bayer Mat Sci, Leverkusen, Germany
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
On-Line Continuous Partial Discharge (PD) measurements of medium voltage substations are an excellent way to determine the overall health of the equipment. Partial discharge measurements can provide maintenance alerts to allow scheduling of equipment outages based on actual condition data as opposed to scheduling based on time intervals. PD measurements provide information about the insulation system that is impossible to extract with other methods. Remote monitoring adds additional value to continuous monitoring by relieving customers of the burden of data analysis, readily involving remote experts. This paper discusses the effectiveness of PD measurements using multiple sensors. Multiple sensors provide additional noise reduction and the ability to localize PD activity for measurements made in higher frequency bands. The importance of continuous PD monitoring vs. periodic walk in PD measurements for switchgear is also discussed. PD activity in switchgear can be unstable and dependent on ambient conditions. Negative periodic PD tests in switchgear can result in a false sense of security. Case studies from field experience are presented to support the discussions.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] CONTINUOUS ON-LINE PARTIAL DISCHARGE MONITORING OF MEDIUM VOLTAGE SUBSTATIONS
    Benzing, Joel
    Blokhintsev, Igor
    Patterson, Calvin
    Loesch, Armin
    Cassidy, Brian J.
    [J]. CONFERENCE RECORD OF 2012 ANNUAL IEEE PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE (PPIC), 2012,
  • [2] Advantage of On-Line Partial Discharge Continuous Monitoring of Medium Voltage Substation
    Blokhintsev, Igor
    Patterson, Calvin L.
    Cassidy, Brian J.
    Loesch, Armin H.
    [J]. 2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 153 - +
  • [3] Development of a continuous on-line partial discharge monitoring system for medium voltage motors
    Stone, GC
    Campbell, SR
    Sedding, HG
    [J]. EIGHTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND DRIVES, 1997, (444): : 123 - 127
  • [4] On-line partial discharge monitoring in medium voltage underground cables
    Zhou, C.
    Michel, M.
    Hepburn, D. M.
    Song, X.
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2009, 3 (05) : 354 - 363
  • [5] Partial discharge diagnosis and monitoring of medium-voltage substations
    Hribernik, W.
    Berger, K.
    Pascoli, G.
    [J]. ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2007, 124 (12): : 430 - 434
  • [6] Development of an on-line partial discharge monitoring system for gas insulated substations
    Sakakibara, T
    Murase, H
    Haginomori, E
    Wakabayashi, S
    Emoto, K
    Ogawa, A
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 1999, 129 (02) : 40 - 50
  • [7] Continuous on-line partial discharge monitoring of power generators
    Kheirmand, A
    Leijon, M
    [J]. IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 496 - 499
  • [8] Continuous and Remote Monitoring of Partial Discharge in Medium Voltage Switchgear
    Blokhintsev, Igor
    Kozusko, Jim
    Oberer, Brian
    Anzaldi, David
    [J]. 2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 205 - 208
  • [9] Continuous on-line partial discharge monitoring of generator stator windings
    Lloyd, BA
    Campbell, SR
    Stone, GC
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) : 1131 - 1137
  • [10] Continuous on-line monitoring of partial discharges in high voltage cables
    Tian, Y
    Lewin, PL
    Wilkinson, JS
    Sutton, SJ
    Swingler, SG
    [J]. CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 454 - 457