CONTINUOUS ON-LINE PARTIAL DISCHARGE MONITORING OF MEDIUM VOLTAGE SUBSTATIONS

被引:0
|
作者
Benzing, Joel [1 ]
Patterson, Calvin L. [1 ]
Cassidy, Brian J. [2 ]
Blokhintsev, Igor [1 ]
Loesch, Armin H. [1 ]
机构
[1] Eaton Corp, Cleveland, OH 44114 USA
[2] Bayer Mat Sci, Leverkusen, Germany
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
On-Line Continuous Partial Discharge (PD) measurements of medium voltage substations are an excellent way to determine the overall health of the equipment. Partial discharge measurements can provide maintenance alerts to allow scheduling of equipment outages based on actual condition data as opposed to scheduling based on time intervals. PD measurements provide information about the insulation system that is impossible to extract with other methods. Remote monitoring adds additional value to continuous monitoring by relieving customers of the burden of data analysis, readily involving remote experts. This paper discusses the effectiveness of PD measurements using multiple sensors. Multiple sensors provide additional noise reduction and the ability to localize PD activity for measurements made in higher frequency bands. The importance of continuous PD monitoring vs. periodic walk in PD measurements for switchgear is also discussed. PD activity in switchgear can be unstable and dependent on ambient conditions. Negative periodic PD tests in switchgear can result in a false sense of security. Case studies from field experience are presented to support the discussions.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] On-line Partial Discharge Monitoring of Substation Power Transformers
    Huzmezan, Mihai
    [J]. 2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 347 - 352
  • [32] On-line partial discharge calibration and monitoring for power transformers
    Farag, AS
    Shewhdi, MH
    Jin, X
    Wang, C
    Cheng, TC
    Dong, X
    Gao, S
    Jing, W
    Wang, Z
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 1999, 50 (01) : 47 - 54
  • [33] Development of on-line monitoring equipment of medium voltage switchgear
    Huang Xiping
    Wang Xin
    Qiang Wen
    [J]. ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL III, 2007, : 388 - +
  • [34] PILOT IMPLEMENTATION OF THE ON-LINE PARTIAL DISCHARGE MONITORING SYSTEM FOR HEADS OF THE HIGH VOLTAGE CABLE LINES
    Konarski, Michal
    Wegierek, Pawel
    [J]. METROLOGY AND MEASUREMENT SYSTEMS, 2020, 27 (02) : 373 - 382
  • [35] Partial Discharge Parameters to Evaluate the Insulation Condition of On-line Located Defects in Medium Voltage Cable Networks
    Gargari, S. Mousavi
    Wouters, P. A. A. F.
    van der Wielen, P. C. J. M.
    Steennis, E. F.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (03) : 868 - 877
  • [36] The Effect of the Ring Mains Units for On-Line Partial Discharge Location With Time Reversal in Medium Voltage Networks
    Ragusa, Antonella
    Wouters, Peter A. A. F.
    Sasse, Hugh G.
    Duffy, Alistair
    [J]. IEEE ACCESS, 2022, 10 : 33844 - 33854
  • [37] Experience with on-line Partial Discharge analysis as a tool for predictive maintenance for medium voltage (MV) switchgear systems
    Smith, JE
    Paoletti, G
    Blokhintsev, I
    [J]. INDUSTRY APPLICATIONS SOCIETY 49TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2002, : 155 - 161
  • [38] On-line physical security monitoring of power substations
    Xie, Jing
    Liu, Chen-Ching
    Sforna, Marino
    Bilek, Martin
    Hamza, Radek
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2016, 26 (06): : 1148 - 1170
  • [39] On-Line Partial Discharge Monitoring and Diagnostic System for Power Transformer
    林渡
    姜磊
    李福祺
    朱德恒
    谈克雄
    吴成琦
    金显贺
    王昌长
    郑振中
    [J]. Tsinghua Science and Technology, 2005, (05) : 598 - 604
  • [40] Research on the On-line Monitoring System for Partial Discharge of Cable Joint
    Li, Yanqing
    Jia, Zihang
    Zhao, Liang
    Liang, Jianfeng
    [J]. MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 986 - +