Breast Cancer Diagnosis Using a Microfluidic Multiplexed Immunohistochemistry Platform

被引:56
|
作者
Kim, Minseok S. [1 ]
Kim, Taemin [2 ]
Kong, Sun-Young [3 ]
Kwon, Soim [4 ]
Bae, Chae Yun [1 ]
Choi, Jaekyu [1 ]
Kim, Chul Hwan [5 ]
Lee, Eun Sook [4 ]
Park, Je-Kyun [1 ,6 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Taejon 305701, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Elect Engn & Comp Sci, Taejon 305701, South Korea
[3] Natl Canc Ctr, Res Inst & Hosp, Dept Lab Med, Goyang, South Korea
[4] Korea Univ, Coll Med, Dept Breast & Endocrine Surg, Seoul 136705, South Korea
[5] Korea Univ, Coll Med, Dept Pathol, Seoul 136705, South Korea
[6] Korea Adv Inst Sci & Technol, Inst NanoCentury, Taejon 305701, South Korea
来源
PLOS ONE | 2010年 / 5卷 / 05期
关键词
SEMICONDUCTOR QUANTUM DOTS; GENE-EXPRESSION PATTERNS; TISSUE MICROARRAYS; PREOPERATIVE CHEMOTHERAPY; MOLECULAR PATHOLOGY; BIOMARKER ANALYSIS; CELLULAR TARGETS; PROSTATE-CANCER; QUANTIFICATION; CARCINOMAS;
D O I
10.1371/journal.pone.0010441
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Biomarkers play a key role in risk assessment, assessing treatment response, and detecting recurrence and the investigation of multiple biomarkers may also prove useful in accurate prediction and prognosis of cancers. Immunohistochemistry (IHC) has been a major diagnostic tool to identify therapeutic biomarkers and to subclassify breast cancer patients. However, there is no suitable IHC platform for multiplex assay toward personalized cancer therapy. Here, we report a microfluidics-based multiplexed IHC (MMIHC) platform that significantly improves IHC performance in reduction of time and tissue consumption, quantification, consistency, sensitivity, specificity and cost-effectiveness. Methodology/Principal Findings: By creating a simple and robust interface between the device and human breast tissue samples, we not only applied conventional thin-section tissues into on-chip without any additional modification process, but also attained perfect fluid control for various solutions, without any leakage, bubble formation, or cross-contamination. Four biomarkers, estrogen receptor (ER), human epidermal growth factor receptor 2 (HER2), progesterone receptor (PR) and Ki-67, were examined simultaneously on breast cancer cells and human breast cancer tissues. The MMIHC method improved immunoreaction, reducing time and reagent consumption. Moreover, it showed the availability of semi-quantitative analysis by comparing Western blot. Concordance study proved strong consensus between conventional whole-section analysis and MMIHC (n = 105, lowest Kendall's coefficient of concordance, 0.90). To demonstrate the suitability of MMIHC for scarce samples, it was also applied successfully to tissues from needle biopsies. Conclusions/Significance: The microfluidic system, for the first time, was successfully applied to human clinical tissue samples and histopathological diagnosis was realized for breast cancers. Our results showing substantial agreement indicate that several cancer-related proteins can be simultaneously investigated on a single tumor section, giving clear advantages and technical advances over standard immunohistochemical method. This novel concept will enable histopathological diagnosis using numerous specific biomarkers at a time even for small-sized specimens, thus facilitating the individualization of cancer therapy.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] EXTRACTION AND QUANTIFICATION OF MICRORNA BIOMARKERS FOR DIAGNOSIS OF OVARIAN CANCER ON AN INTEGRATED MICROFLUIDIC PLATFORM
    Sung, Chia-Yu
    Huang, Chi-Chien
    Chen, Yi-Sin
    Lee, Gwo-Bin
    2021 34TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2021), 2021, : 366 - 369
  • [42] Microfluidic Platform for Profiling of Extracellular Vesicles from Single Breast Cancer Cells
    Nikoloff, Jonas M.
    Saucedo-Espinosa, Mario A.
    Dittrich, Petra S.
    ANALYTICAL CHEMISTRY, 2023, 95 (03) : 1933 - 1939
  • [43] Multiplexed Immunohistochemistry Image Analysis using Sparse Coding
    Chang, Young Hwan
    Tsujikawa, Takahiro
    Margolin, Adam
    Coussens, Lisa M.
    Gray, Joe W.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 4046 - 4049
  • [44] Micro-immunohistochemistry using a microfluidic probe
    Lovchik, Robert D.
    Kaigala, Govind V.
    Georgiadis, Marios
    Delamarche, Emmanuel
    LAB ON A CHIP, 2012, 12 (06) : 1040 - 1043
  • [45] Significance of immunohistochemistry in breast cancer
    Zaha, Dana Carmen
    WORLD JOURNAL OF CLINICAL ONCOLOGY, 2014, 5 (03): : 382 - 392
  • [46] Small extracellular vesicles detection using dielectrophoresis-based microfluidic chip for diagnosis of breast cancer
    Lan, Mei
    Ren, Ze
    Cheng, Cheng
    Li, Guiying
    Yang, Fang
    BIOSENSORS & BIOELECTRONICS, 2024, 259
  • [47] AN INTEGRATED MICROFLUIDIC SYSTEM FOR EARLY DIAGNOSIS OF BREAST CANCER IN LIQUID BIOPSY BY USING MICRORNA AND FET BIOSENSORS
    Huang, Chi-Chien
    Kuo, Yu-Husan
    Chen, Yi-Sin
    Lee, Gwo-Bin
    2021 34TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2021), 2021, : 318 - 321
  • [48] Biomarker barcodes: multiplexed microfluidic immunohistochemistry enables high-throughput analysis of tissue microarray
    Cho, Chang Hyun
    Cho, Minkyung
    Park, Je-Kyun
    LAB ON A CHIP, 2021, 21 (18) : 3471 - 3482
  • [49] Enantioanalysis of Cysteine Using an Enantioselective Stochastic Platform: A Key Factor on Early Diagnosis of Breast Cancer
    Negut, Catalina Cioates
    Stefan-van Staden, Raluca-Ioana
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (03)
  • [50] A microfluidic ExoSearch chip for multiplexed exosome detection towards blood-based ovarian cancer diagnosis
    Zhao, Zheng
    Yang, Yang
    Zeng, Yong
    He, Mei
    LAB ON A CHIP, 2016, 16 (03) : 489 - 496