Breast Cancer Diagnosis Using a Microfluidic Multiplexed Immunohistochemistry Platform

被引:56
|
作者
Kim, Minseok S. [1 ]
Kim, Taemin [2 ]
Kong, Sun-Young [3 ]
Kwon, Soim [4 ]
Bae, Chae Yun [1 ]
Choi, Jaekyu [1 ]
Kim, Chul Hwan [5 ]
Lee, Eun Sook [4 ]
Park, Je-Kyun [1 ,6 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Taejon 305701, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Elect Engn & Comp Sci, Taejon 305701, South Korea
[3] Natl Canc Ctr, Res Inst & Hosp, Dept Lab Med, Goyang, South Korea
[4] Korea Univ, Coll Med, Dept Breast & Endocrine Surg, Seoul 136705, South Korea
[5] Korea Univ, Coll Med, Dept Pathol, Seoul 136705, South Korea
[6] Korea Adv Inst Sci & Technol, Inst NanoCentury, Taejon 305701, South Korea
来源
PLOS ONE | 2010年 / 5卷 / 05期
关键词
SEMICONDUCTOR QUANTUM DOTS; GENE-EXPRESSION PATTERNS; TISSUE MICROARRAYS; PREOPERATIVE CHEMOTHERAPY; MOLECULAR PATHOLOGY; BIOMARKER ANALYSIS; CELLULAR TARGETS; PROSTATE-CANCER; QUANTIFICATION; CARCINOMAS;
D O I
10.1371/journal.pone.0010441
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Biomarkers play a key role in risk assessment, assessing treatment response, and detecting recurrence and the investigation of multiple biomarkers may also prove useful in accurate prediction and prognosis of cancers. Immunohistochemistry (IHC) has been a major diagnostic tool to identify therapeutic biomarkers and to subclassify breast cancer patients. However, there is no suitable IHC platform for multiplex assay toward personalized cancer therapy. Here, we report a microfluidics-based multiplexed IHC (MMIHC) platform that significantly improves IHC performance in reduction of time and tissue consumption, quantification, consistency, sensitivity, specificity and cost-effectiveness. Methodology/Principal Findings: By creating a simple and robust interface between the device and human breast tissue samples, we not only applied conventional thin-section tissues into on-chip without any additional modification process, but also attained perfect fluid control for various solutions, without any leakage, bubble formation, or cross-contamination. Four biomarkers, estrogen receptor (ER), human epidermal growth factor receptor 2 (HER2), progesterone receptor (PR) and Ki-67, were examined simultaneously on breast cancer cells and human breast cancer tissues. The MMIHC method improved immunoreaction, reducing time and reagent consumption. Moreover, it showed the availability of semi-quantitative analysis by comparing Western blot. Concordance study proved strong consensus between conventional whole-section analysis and MMIHC (n = 105, lowest Kendall's coefficient of concordance, 0.90). To demonstrate the suitability of MMIHC for scarce samples, it was also applied successfully to tissues from needle biopsies. Conclusions/Significance: The microfluidic system, for the first time, was successfully applied to human clinical tissue samples and histopathological diagnosis was realized for breast cancers. Our results showing substantial agreement indicate that several cancer-related proteins can be simultaneously investigated on a single tumor section, giving clear advantages and technical advances over standard immunohistochemical method. This novel concept will enable histopathological diagnosis using numerous specific biomarkers at a time even for small-sized specimens, thus facilitating the individualization of cancer therapy.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Microfluidic Platform for Investigation of Mechanoregulation of Breast Cancer Bone Metastasis
    Mei, Xueting
    Middleton, Kevin
    Ma, Yu-Heng
    Xu, Liangcheng
    Walji, Noosheen
    Young, Edmond
    You, Lidan
    JOURNAL OF BONE AND MINERAL RESEARCH, 2018, 33 : 340 - 340
  • [22] Diagnosis of breast cancer recurrence using a microfluidic device featuring tethered cationic polymers
    Chen, Jem-Kun
    Bai, Bing-Jun
    Chang, Feng-Chih
    APPLIED PHYSICS LETTERS, 2011, 99 (01)
  • [23] OncoFlow: A multiplexed microfluidic platform for personalized drug sensitivity assessment
    Krasner, Matan
    Barbiro-Michaely, Efrat
    Abu-Shach, Ulrike Bening
    Onn, Amir
    Broday, Limor
    Gerber, Doron
    NEW BIOTECHNOLOGY, 2025, 87 : 105 - 111
  • [24] Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
    Wang, Ningquan
    Liu, Ruxiu
    Sarioglu, A. Fatih
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (121):
  • [25] A Microfluidic Platform for High-Throughput Multiplexed Protein Quantitation
    Volpetti, Francesca
    Garcia-Cordero, Jose
    Maerkl, Sebastian J.
    PLOS ONE, 2015, 10 (02):
  • [26] Automated microfluidic processing platform for multiplexed magnetic bead immunoassays
    Sasso, Lawrence A.
    Johnston, Ian H.
    Zheng, Mingde
    Gupte, Rohit K.
    Uendar, Akif
    Zahn, Jeffrey D.
    MICROFLUIDICS AND NANOFLUIDICS, 2012, 13 (04) : 603 - 612
  • [27] Automated microfluidic processing platform for multiplexed magnetic bead immunoassays
    Lawrence A. Sasso
    Ian H. Johnston
    Mingde Zheng
    Rohit K. Gupte
    Akif Ündar
    Jeffrey D. Zahn
    Microfluidics and Nanofluidics, 2012, 13 : 603 - 612
  • [28] A smart microfluidic platform for rapid multiplexed detection of foodborne pathogens
    Azinheiro, Sarah
    Kant, Krishna
    Shahbazi, Mohammad-Ali
    Garrido-Maestu, Alejandro
    Prado, Marta
    Dieguez, Lorena
    FOOD CONTROL, 2020, 114
  • [29] Microfluidic platform for studying osteocyte mechanoregulation of breast cancer bone metastasis
    Mei, Xueting
    Middleton, Kevin
    Shim, Dongsub
    Wan, Qianqian
    Xu, Liangcheng
    Ma, Yu-Heng Vivian
    Devadas, Deepika
    Walji, Noosheen
    Wang, Liyun
    Young, Edmond W. K.
    You, Lidan
    INTEGRATIVE BIOLOGY, 2019, 11 (04) : 119 - 129
  • [30] Molecular Classification of Male Breast Cancer Using Immunohistochemistry
    Al-Saati, G.
    Jensen, K. C.
    MODERN PATHOLOGY, 2010, 23 : 33A - 33A