Post-tensioning of glulam timber with steel tendons

被引:52
|
作者
McConnell, E. [1 ]
McPolin, D. [1 ]
Taylor, S. [1 ]
机构
[1] Queens Univ Belfast, Dept Civil Engn, Belfast BT7 1NN, Antrim, North Ireland
关键词
Post-tension; Glulam; Timber; Steel; Four-point bending; BEHAVIOR;
D O I
10.1016/j.conbuildmat.2014.09.079
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes a series of four-point bending tests that were conducted, under service loads and to failure, on unreinforced, reinforced and post-tensioned glulam timber beams, where the reinforcing tendon used was 12 mm diameter toughened steel bar. The research was designed to evaluate the benefits offered by including an active reinforcement in contrast to the passive reinforcement typically used within timber strengthening works, in addition to establishing the effect that bonding the reinforcing tendon has on the materials performance. The laboratory investigations established that the flexural strength and stiffness increased for both the reinforced and post-tensioned timbers compared to the unreinforced beams. The flexural strength of the reinforced timber increased by 29.4%, while the stiffness increased by 28.1%. Timber that was post-tensioned with an unbonded steel tendon showed a flexural strength increase of 17.6% and an increase in stiffness of 8.1%. Post-tensioned beams with a bonded steel tendon showed increases in flexural strength and stiffness of 40.1% and 30% respectively. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:426 / 433
页数:8
相关论文
共 50 条
  • [21] IMPROVED SUSTAINABILITY IN POST-TENSIONING BY REPLACEABLE INTERNAL UNBONDED TENDONS
    Traute, Markus
    Weiher, Hermann
    [J]. FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 831 - 834
  • [22] Post-tensioning cuts steel bridge costs
    Spaans, Leo
    [J]. Modern Steel Construction, 1994, 34 (09): : 38 - 43
  • [23] Ultimate stress for unbonded post-tensioning tendons in partially prestressed beams
    Chakrabarti, PR
    [J]. ACI STRUCTURAL JOURNAL, 1995, 92 (06) : 689 - 697
  • [24] Impregnation Technique Provides Corrosion Protection to Grouted Post-Tensioning Tendons
    Whitmore, David
    Lasa, Ivan
    [J]. INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, REHABILITATION AND RETROFITTING (ICCRRR 2018), 2018, 199
  • [25] A Local Compression Tests of UHPC Anchor Blocks for Post-Tensioning Tendons
    Choi, Eun Suk
    Lee, Jung Woo
    Joh, Changbin
    Kwark, Jong Won
    Kim, Jee Sang
    Choi, Yoon Seok
    [J]. ADVANCES IN FRACTURE AND DAMAGE MECHANICS XI, 2013, 525-526 : 561 - +
  • [26] A thermal analysis of flexible filler injection for unbonded post-tensioning tendons
    Abdullah, A. B. M.
    Rice, Jennifer A.
    Bhatia, Rahul
    Brenkus, Natassia R.
    Hamilton, H. R.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 126 : 599 - 608
  • [27] X-ray diffraction measurement of stresses in post-tensioning tendons
    Carfagno, MG
    Noorai, FS
    Brauss, ME
    Pineault, JA
    [J]. NONDESTRUCTIVE EVALUATION OF BRIDGES AND HIGHWAYS, 1996, 2946 : 51 - 56
  • [28] Friction characteristics of post-tensioning tendons in full-scale structures
    Kim, Sang-Hyun
    Park, Sung Yong
    Park, YoungHwan
    Jeon, Se-Jin
    [J]. ENGINEERING STRUCTURES, 2019, 183 : 389 - 397
  • [29] A new steel anchorage system for post-tensioning applications using carbon fibre reinforced plastic tendons
    Sayed-Ahmed, EY
    Shrive, NG
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 1998, 25 (01) : 113 - 127
  • [30] Post-tensioning primer
    [J]. Aberdeen's Concrete Construction, 1999, 44 (02):