IMPROVED SUSTAINABILITY IN POST-TENSIONING BY REPLACEABLE INTERNAL UNBONDED TENDONS

被引:0
|
作者
Traute, Markus [1 ]
Weiher, Hermann [2 ]
机构
[1] DYWIDAG Syst Int GmbH, Siemensstr 8, D-85716 Unterschleissheim, Germany
[2] Matr Engn GmbH, D-80333 Munich, Germany
关键词
nbonded post-tensioning; Service life aspects; Sustainable structures;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The bridge design with external Post-tensioning has been established and applied successfully in the last two decades. In Germany consequently the development moved towards using unbonded tendons also internally. In comparison with solely externally prestressed structures the lever arm in box girders can be improved significantly and the application is also interesting for massive cross section design like T-beams. On basis of its established SUSPA-Wire Ex system for external Post-tensioning DSI has developed SUSPA-Wire internal with a fully restressable and replaceable tendon meeting the requirements of a suitable PT-system for the new concept of PC structures. Several pilot projects have been carried out in the last years. The replaceability has been proven recently on a road bridge project in South Germany on a tendon of some 84 m length. The insitu test has been supervised by an independent laboratory and additionally reviewed by an accredited expert.
引用
下载
收藏
页码:831 / 834
页数:4
相关论文
共 50 条
  • [1] Specifications for Unbonded Post-Tensioning Tendons
    1600, American Concrete Institute (38):
  • [2] REALISTIC REQUIREMENTS FOR UNBONDED POST-TENSIONING TENDONS
    BONDY, KB
    KOURKENE, JP
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1971, 16 (01): : 63 - &
  • [3] REALISTIC REQUIREMENTS FOR UNBONDED POST-TENSIONING TENDONS
    BONDY, KB
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1970, 15 (01): : 50 - &
  • [4] MOVEMENT OF UNBONDED POST-TENSIONING TENDONS DURING DEMOLITION
    WILLIAMS, MS
    WALDRON, P
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1989, 87 : 225 - 253
  • [5] Guidelines for Evaluation of a Structure with Unbonded Post-tensioning Tendons
    Kelley, Gail S.
    Concrete International, 2002, 24 (08) : 79 - 85
  • [6] Factors that influence friction in tendons of unbonded post-tensioning systems
    Dundu, Morgan
    Ward, Michelle
    CONSTRUCTION MATERIALS AND STRUCTURES, 2014, : 1141 - 1147
  • [7] Fatigue of Diabolo-Deviated Unbonded Post-Tensioning Tendons
    Brenkus, Natassia
    Skelton, Devon
    Hamilton, H. R.
    ACI STRUCTURAL JOURNAL, 2021, 118 (05) : 27 - 36
  • [8] Ultimate stress for unbonded post-tensioning tendons in partially prestressed beams
    Chakrabarti, PR
    ACI STRUCTURAL JOURNAL, 1995, 92 (06) : 689 - 697
  • [9] A thermal analysis of flexible filler injection for unbonded post-tensioning tendons
    Abdullah, A. B. M.
    Rice, Jennifer A.
    Bhatia, Rahul
    Brenkus, Natassia R.
    Hamilton, H. R.
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 126 : 599 - 608
  • [10] GROUTING OF POST-TENSIONING TENDONS
    SCHUPACK, M