IMPROVED SUSTAINABILITY IN POST-TENSIONING BY REPLACEABLE INTERNAL UNBONDED TENDONS

被引:0
|
作者
Traute, Markus [1 ]
Weiher, Hermann [2 ]
机构
[1] DYWIDAG Syst Int GmbH, Siemensstr 8, D-85716 Unterschleissheim, Germany
[2] Matr Engn GmbH, D-80333 Munich, Germany
关键词
nbonded post-tensioning; Service life aspects; Sustainable structures;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The bridge design with external Post-tensioning has been established and applied successfully in the last two decades. In Germany consequently the development moved towards using unbonded tendons also internally. In comparison with solely externally prestressed structures the lever arm in box girders can be improved significantly and the application is also interesting for massive cross section design like T-beams. On basis of its established SUSPA-Wire Ex system for external Post-tensioning DSI has developed SUSPA-Wire internal with a fully restressable and replaceable tendon meeting the requirements of a suitable PT-system for the new concept of PC structures. Several pilot projects have been carried out in the last years. The replaceability has been proven recently on a road bridge project in South Germany on a tendon of some 84 m length. The insitu test has been supervised by an independent laboratory and additionally reviewed by an accredited expert.
引用
下载
收藏
页码:831 / 834
页数:4
相关论文
共 50 条
  • [31] X-ray diffraction measurement of stresses in post-tensioning tendons
    Carfagno, MG
    Noorai, FS
    Brauss, ME
    Pineault, JA
    NONDESTRUCTIVE EVALUATION OF BRIDGES AND HIGHWAYS, 1996, 2946 : 51 - 56
  • [32] Transverse diaphragms and unbonded CFRP post-tensioning in box-beam bridges
    Grace, Nabil F.
    Jensen, Elin A.
    Enomoto, Tsuyoshi
    Matsagar, Vasant A.
    Soliman, Eslam M.
    Hanson, Joseph Q.
    PCI JOURNAL, 2010, : 109 - 122
  • [33] Friction characteristics of post-tensioning tendons in full-scale structures
    Kim, Sang-Hyun
    Park, Sung Yong
    Park, YoungHwan
    Jeon, Se-Jin
    ENGINEERING STRUCTURES, 2019, 183 : 389 - 397
  • [34] Post-tensioning primer
    Aberdeen's Concrete Construction, 1999, 44 (02):
  • [35] Testing and analysing innovative design of UHPFRC anchor blocks for post-tensioning tendons
    Toutlemonde, F.
    Renaud, J. -C.
    Lauvin, L.
    Behloul, M.
    Simon, A.
    Vildaer, S.
    FRACTURE MECHANICS OF CONCRETE AND CONCRETE STRUCTURES, VOLS 1-3: VOL 1: NEW TRENDS IN FRACTURE MECHANICS OF CONCRETE; VOL 2: DESIGN, ASSESSMENT AND RETROFITTING OF RC STRUCTURES; VOL 3: HIGH-PERFORMANCE CONCRETE, BRICK-MASONRY AND ENVIRONMENTAL ASPECTS, 2007, 1-3 : 1193 - 1201
  • [36] Flexible filler mock-up injections of bridge post-tensioning tendons
    Brenkus, Natassia R.
    Bhatia, Rahul
    Potter, Will A.
    Hamilton, H. R., III
    PCI JOURNAL, 2018, : 65 - 76
  • [37] Behavior of unbonded post-tensioning monostrand anchorage systems under monotonic tensile loading
    Walsh, Kevin Q.
    Kurama, Yahya C.
    PCI JOURNAL, 2010, 55 (01): : 97 - 117
  • [38] Effects of loading conditions on the behavior of unbonded post-tensioning strand-anchorage systems
    Walsh, Kevin Q.
    Kurama, Yahya C.
    PCI JOURNAL, 2012, : 76 - 96
  • [39] Fatigue assessment of non-metallic anchors for post-tensioning CFRP tendons
    Taha, MMR
    Shrive, NG
    COMPOSITES IN CONSTRUCTION, 2001, : 345 - 350
  • [40] Improved estimation of the reverse-cyclic behavior of fully-grouted masonry shear walls with unbonded post-tensioning
    Kalliontzis, D.
    Schultz, A. E.
    ENGINEERING STRUCTURES, 2017, 145 : 83 - 96