IMPROVED SUSTAINABILITY IN POST-TENSIONING BY REPLACEABLE INTERNAL UNBONDED TENDONS

被引:0
|
作者
Traute, Markus [1 ]
Weiher, Hermann [2 ]
机构
[1] DYWIDAG Syst Int GmbH, Siemensstr 8, D-85716 Unterschleissheim, Germany
[2] Matr Engn GmbH, D-80333 Munich, Germany
关键词
nbonded post-tensioning; Service life aspects; Sustainable structures;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The bridge design with external Post-tensioning has been established and applied successfully in the last two decades. In Germany consequently the development moved towards using unbonded tendons also internally. In comparison with solely externally prestressed structures the lever arm in box girders can be improved significantly and the application is also interesting for massive cross section design like T-beams. On basis of its established SUSPA-Wire Ex system for external Post-tensioning DSI has developed SUSPA-Wire internal with a fully restressable and replaceable tendon meeting the requirements of a suitable PT-system for the new concept of PC structures. Several pilot projects have been carried out in the last years. The replaceability has been proven recently on a road bridge project in South Germany on a tendon of some 84 m length. The insitu test has been supervised by an independent laboratory and additionally reviewed by an accredited expert.
引用
下载
收藏
页码:831 / 834
页数:4
相关论文
共 50 条
  • [21] Comparative statistical study for the ultimate stress in unbonded post-tensioning
    Ament, JM
    Chakrabarti, PR
    Putcha, CS
    ACI STRUCTURAL JOURNAL, 1997, 94 (02) : 171 - 180
  • [22] UNBONDED SINGLE STRAND POST-TENSIONING TENDON DETAILS.
    Schupack, Morris
    Concrete Construction - World of Concrete, 1988, 33 (07): : 668 - 670
  • [24] Design criterion for the self-centering capacity of precast segmental UHPC bridge columns with unbonded post-tensioning tendons
    Wang, Zhen
    Wang, Jingquan
    Zhao, Guotang
    Zhang, Jian
    ENGINEERING STRUCTURES, 2019, 200
  • [25] A damage detection model for unbonded post-tensioning tendons based on relative strain variation in multi-strand anchors
    Abdullah, A. B. M.
    Rice, Jennifer A.
    Hamilton, H. R.
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2014, 2014, 9061
  • [27] POST-TENSIONING
    HANUSCHAK, W
    CIVIL ENGINEERING, 1983, 53 (03): : 30 - 30
  • [28] Post-tensioning glulam timber beams with basalt FRP tendons
    McConnell, Emma
    McPolin, Daniel
    Taylor, Su
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CONSTRUCTION MATERIALS, 2015, 168 (05) : 232 - 240
  • [29] A Local Compression Tests of UHPC Anchor Blocks for Post-Tensioning Tendons
    Choi, Eun Suk
    Lee, Jung Woo
    Joh, Changbin
    Kwark, Jong Won
    Kim, Jee Sang
    Choi, Yoon Seok
    ADVANCES IN FRACTURE AND DAMAGE MECHANICS XI, 2013, 525-526 : 561 - +
  • [30] Impregnation Technique Provides Corrosion Protection to Grouted Post-Tensioning Tendons
    Whitmore, David
    Lasa, Ivan
    INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, REHABILITATION AND RETROFITTING (ICCRRR 2018), 2018, 199