Investigation Regarding Corona Free Endwinding Design of Form Wound High Voltage Stator Windings

被引:0
|
作者
Lerchbacher, M. [1 ]
Imamovic, D. [1 ]
Lemesch, G. [2 ]
Ramsauer, F. [2 ]
Muhr, M. [1 ]
机构
[1] Graz Univ Technol, Inst High Voltage Engn & Syst Management, Graz, Austria
[2] Andritz Hydro GmbH, Weiz, Austria
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High voltage rotating machines are supposed to be optimized not only in terms of performance but -among others also with respect to space and material utilization. When designing machines there has been considerable effort made to reduce the overall size of generators particularly in the axial direction. The winding is one of the more demanding parts of the generator but the end winding is an obvious place where axial space could be saved. For an optimized design, the distance between adjacent insulated bars or coils is a very important factor. Inadequate end winding spacing can lead to corona activity between adjacent coils or bars. Exact prediction of the needed space is difficult as prediction is dependent upon several contributing factors. Dielectric properties of the insulation material, location of the bracing system, imperfection of insulation surface as well as of the corona inception and extinction voltage in the air gap between insulated electrodes are important factors to understand for an optimized end winding design. In this paper the results of experimental investigations on air for various electrode configurations are presented. Metallic electrodes were covered with standard insulation material which is used in generators. The corona inception and extinction voltages as well as the partial discharge rate and the amplitude were measured for different electrode configurations. Additionally, the corona discharges were monitored with a special UV camera. The distance and the pressure of the air were varied in a wide range. The main purpose of this study was to optimize and simplify the spacing requirements of the end winding design. Therefore the corona inception and extinction voltage in the air gap between insulated electrodes as a function of distance and pressure was measured. Subsequent to that, the translation between the classical Paschen's Law for breakdown and the corona inception and extinction voltage in the air gap between insulated electrodes was investigated.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Reduction Techniques of Partial Discharge, Dissipation Factor, and External Corona for High Voltage Stator Windings
    Emery, F. T.
    [J]. 2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 315 - 327
  • [2] Turbo generator with high voltage stator windings
    Flockermann, D
    Kulig, S
    [J]. ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 620 - 624
  • [3] Partial discharge, dissipation factor, and corona aspects for high voltage electric generator stator bars and windings
    Emery, FT
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (02) : 347 - 361
  • [4] Power Factor measurements on high voltage Stator bars & Stator windings
    Emery, FT
    [J]. CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 502 - 505
  • [5] Basics of power factor measurements on high voltage stator bars & stator windings
    Emery, FT
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2004, 20 (03) : 40 - 45
  • [6] High frequency and high voltage tests on electric motors stator windings
    Guastavino, F
    Cerutti, B
    Bona, S
    Colombo, C
    Mariani, A
    [J]. ICSD '01: PROCEEDINGS OF THE 2001 IEEE 7TH INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, 2001, : 268 - 271
  • [7] Analysis of partial discharge to high voltage motor stator windings
    Kim, HD
    [J]. 2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 340 - 343
  • [8] The Effect of Temperature on Slot Discharge for High Voltage Stator Windings
    Duan, Dingqiang
    Wang, Fei
    [J]. 3RD ASIAN PACIFIC CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (APEESD 2017), 2017, : 31 - 36
  • [9] Experimental Investigation of the Voltage Distribution in Form Wound Windings of Large AC Machines due to Fast Transients
    Krings, Andreas
    Paulsson, Goran
    Sahlen, Fredrik
    Holmgren, Bjorn
    [J]. 2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2016, : 1700 - 1706
  • [10] Measurement and analysis of partial discharge in high voltage motor stator windings
    Kim, HD
    Ju, YH
    [J]. PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING TECHNOLOGY CONFERENCE, 2003, : 27 - 31