Acute Phase Response and Non-Reproducible Elevated Concentrations with a High-Sensitivity Cardiac Troponin I Assay

被引:17
|
作者
Kavsak, Peter A. [1 ,2 ,3 ]
Clark, Lorna [2 ,3 ]
Martin, Janet [1 ]
Mark, Ching-Tong [2 ,3 ]
Pare, Guillaume [1 ]
Mondoux, Shawn [4 ]
Chetty, V. Tony [1 ]
Ainsworth, Craig [5 ]
Worster, Andrew [4 ]
机构
[1] McMaster Univ, Dept Pathol & Mol Med, Hamilton, ON L8S 4L8, Canada
[2] Hamilton Hlth Sci, Core Lab, Juravinski Hosp, Hamilton, ON L8V 1C3, Canada
[3] Hamilton Hlth Sci, Canc Ctr, Hamilton, ON L8V 1C3, Canada
[4] McMaster Univ, Dept Med, Div Emergency Med, Hamilton, ON L8S 4L8, Canada
[5] McMaster Univ, Dept Med, Div Cardiol, Hamilton, ON L8S 4L8, Canada
基金
加拿大健康研究院;
关键词
high-sensitivity cardiac troponin I; myocardial injury; analytical error; interferences; UPPER REFERENCE LIMITS;
D O I
10.3390/jcm10051014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
High-sensitivity cardiac troponin (hs-cTn) testing has enabled physicians to make earlier diagnostic and prognostic decisions in the hospital setting than previous cardiac troponin assays. Analytical improvements have permitted one to measure cardiac troponin precisely in the nanogram per litre (ng/L) range with hs-cTn assays which has resulted in fast 0/1-h and 0/2-h algorithms for ruling-in and ruling-out myocardial infarction. Although analytical interferences that affect the reporting of hs-cTn are uncommon, not all hs-cTn assays are designed the same nor have undergone the same clinical and analytical validations. Here, after investigating an initial case of discrepant hs-cTnI results, we report that patients with an acute phase response (e.g., patients with inflammatory or infectious illnesses) can yield high and non-reproducible results with the Ortho Clinical Diagnostics hs-cTnI assay. Compared to Abbott Diagnostics hs-cTnI, Ortho Clinical Diagnostics hs-cTnI assay misclassifies biochemical injury in approximately 10% of the population being assessed for myocardial injury with imprecise results in approximately half of this population (i.e., 5%). In conclusion, caution is warranted in interpreting Ortho Clinical Diagnostics hs-cTnI alone in patients being evaluated for myocardial injury, especially in patients whose primary presentation is related to an acute phase response and not an acute coronary syndrome symptom.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [41] Elevated circulating high-sensitivity cardiac troponin t and cardiac remodeling in obesity
    Huang, Jiaojiao
    Liu, Ming
    Su, Enyong
    Yu, Peng
    Jiang, Hong
    Zhao, Ji
    Ge, Junbo
    BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)
  • [42] Elevated circulating high-sensitivity cardiac troponin t and cardiac remodeling in obesity
    Jiaojiao Huang
    Ming Liu
    Enyong Su
    Peng Yu
    Hong Jiang
    Ji Zhao
    Junbo Ge
    BMC Cardiovascular Disorders, 21
  • [43] Prevalence and determinants of elevated high-sensitivity cardiac troponin I in Emergency patients with Atrial Fibrillation
    Zhang Han
    Zhu Jun
    Tian Li
    Huang Bi
    Wang Juan
    Yang Yanmin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C161 - C161
  • [44] Prevalence and determinants of elevated high-sensitivity cardiac troponin I in emergency patients with atrial fibrillation
    Zhang, Han
    Yang, Yanmin
    Zhu, Jun
    CARDIOLOGY, 2014, 129 : 95 - 95
  • [45] Evaluation of a high-sensitivity cardiac troponin I assay compared to a first-generation cardiac troponin I assay in Doberman Pinschers with and without dilated cardiomyopathy
    Klueser, Lena
    Maier, Elizabeth T.
    Wess, Gerhard
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2019, 33 (01) : 54 - 63
  • [46] Prevalence of elevated cardiac troponin T in ICU patients using the high-sensitivity assay and the relationship with mortality
    S O'Sullivan
    M Sutton
    G Fitzpatrick
    Critical Care, 18 (Suppl 1):
  • [47] Circulating Cardiac Troponin I as Detected By a High-Sensitivity Assay among Patients Hospitalized with Acute Decompensated Heart Failure
    Kociol, Robb D.
    McNulty, Steven E.
    Lee, Kerry L.
    Apple, Fred S.
    Tracy, Russell P.
    Hernandez, Adrian F.
    Mentz, Robert J.
    Braunwald, Eugene
    O'Connor, Christopher M.
    Felker, G. Michael
    CIRCULATION, 2011, 124 (21)
  • [48] Validation and direct comparison of a novel high-sensitivity cardiac troponin I assay for early diagnosis of acute myocardial infarction
    Boeddinghaus, J.
    Twerenbold, R.
    Nestelberger, T.
    Badertscher, P.
    Gimenez, M. Rubini
    Wildi, K.
    Puelacher, C.
    Reichlin, T.
    Mueller, C.
    EUROPEAN HEART JOURNAL, 2017, 38 : 999 - 999
  • [49] Benefits of high-sensitivity cardiac troponin assay for athletes' cardiac health monitoring
    Roli, L.
    Tagliavini, S.
    Trenti, T.
    Savino, G.
    D'alisera, R.
    Nasi, M.
    Cossarizza, A.
    Varani, M.
    CLINICA CHIMICA ACTA, 2019, 493 : S494 - S495
  • [50] Total Analytic Error for Low Cardiac Troponin Concentrations (≤10 ng/L) by Use of a High-Sensitivity Cardiac Troponin Assay Reply
    Suzuki, Tom
    Heaney, Liam M.
    Jones, Donald J. L.
    Ng, Leong L.
    CLINICAL CHEMISTRY, 2017, 63 (05) : 1046 - 1047